SuperFish RC 26000 PandECO Plus Electronic Filter Pump with Remote Control User Manual

June 4, 2024
SuperFish

SuperFish logo

User manual.SuperFish RC 26000 PandECO Plus Electronic Filter Pump with
Remote Control- fig

PondECO Plus
RC 26000

RC 26000 PandECO Plus Electronic Filter Pump with Remote Control

Electronic filter pump with remote control –

SuperFish RC 26000 PandECO Plus Electronic Filter Pump with Remote Control-
fig 1| SuperFish RC 26000 PandECO Plus Electronic Filter Pump with Remote Control-
fig 2
---|---

Translation of original manual.
SuperFish PondECO Plus RC 26000 Pump

General instructions

Read this manual carefully before using this device. Keep this manual for future reference.
Meaning of symbols
The following warning symbols and/or signal words are used in this manual:
DANGER!
This means an imminent danger due to electric current. Failure to follow the safety instructions can result in serious or fatal injury and/or serious damage to the product or environment.
WARNING!
This means a dangerous situation. Failure to follow the safety instructions can result in moderate or minor personal injury and/or damage to the product or environment.
NOTICE!
This means caution, useful information or advice.
Fig. … This refers to the relevant drawing … on pages 2 and 3 of this manual.
Meaning of the symbols on the device itself:

| This device (pump) is suitable for outdoor use and can be used underwater up to a 2-metre depth.
---|---
IP68| This device (pump) is waterproof.
| This device (remote control) has protection class III.
| This device complies with all applicable EU standards.
| This device may not be disposed of with normal household waste but must be collected separately for recycling.

Use

Suitable for outdoor use, for pumping pond water within the pond, and for inline set-up.

  • The temperature of the pond water being pumped should not exceed 35°C.
  • Do not use for pumping salt water, sewage water, flammable, corrosive, and/or explosive liquids (e.g. petroleum, petrol, solvents), fats, oils or foodstuffs.
  • Never run the device without water.
  • Do not use for swimming pools and do not connect to drinking water supplies.

Safety

Always follow the safety instructions below for the safe use of the device. Failure to follow these instructions may endanger persons or the environment.

  • **** This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • Ensure the voltage shown on the label matches the main supply voltage.
  • This device must be connected to a socket that is earthed.
  • Protect the socket and plug against moisture. Use a drip loop to ensure water cannot reach the socket and plug the connection of the receiver via the cord (see Fig. A).
  • The receiver must be installed in a dry place, with a minimum of 2-meter clearing from the pond.
  • Don’t use the product if the device, cord or plug is damaged. Return the device to your dealer for repair or recycling. A damaged cord or plug cannot be replaced, the device should be recycled.
  • Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.
  • Never use the device when there are people in the water.
  • Always switch off all devices at the main supply before maintenance.
  • Do not move or lift the device out of the water by the cord, only lift the device by the handle.
  • **** This device can be used by children aged 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and maintenance of the device shall not be done by children without supervision.
  • Modifications to the device may affect safety. The warranty will also expire.

Function

The PondECO Plus RC is an electronic pond pump for use with filters, skimmers, waterfalls, and water ornaments. The pump is equipped with remote control and receiver which regulate the pump capacity and stepped head.
Run Dry Protection
The pump is equipped with a dry-running safety device, which is especially important when used in line. It is important that water can always be pumped around. If there is no water flow for 10 seconds, the pump will automatically stop and then restart after 10 seconds. If there is still no water flow, the pump will stop and restart again. This cycle is repeated 5 times, after which the pump stops completely. You can restart the pump when the water supply is restored. Pull the plug out of the socket, wait 60 seconds, and plug it in again. The pump will now start up and pump water around.
Thermal overload protection
The pump has thermal overload protection in case the motor overheats, the pump switches off automatically. After a cooling down time of 15 to 20 minutes, the pump automatically switches on again. In order to prevent damage to the pump, it is essential to investigate the cause of the overheating and resolve the issue. Damage caused by overheating is not covered by the warranty.

Pond installation

Fig. B The PondECO RC pump is suitable for pond hoses with diameters of 40 and 50 mm. Cut the Multi-step hose connector to the desired diameter and fasten it on the pump.

  • Connect the pond hose to the hose connector using a hose clamp (not included).
    Fig. C Preferably installs the pump in the deepest part of the pond (max. 2 meter depth), or at least 20 cm below the water surface.

  • Make sure that the pump stands horizontally and firmly on a flat surface so that it cannot fall over.

Inline installation
Fig. D For inline use, the pump section must be taken out of the housing.
Fig. E Open the housing by pressing the latch at the front and back, which will release the upper shell.
Fig. F Remove the bracket that runs over the pump by unscrewing the 2 screws and taking the pump out of the housing.

  • At the front of the pump is the inlet (suitable hose connector (Art. 07070309) not supplied). At the top is the outlet (for the supplied hose connector (Art. 07070309)).
    Fig. B First, cut the hose connectors to the desired diameter and then fasten them to the pump.

  • Connect the pond hoses to the hose connectors using hose clamps (not included).

  • Install the pump horizontally and firmly on a flat surface outside the pond. Make sure that the pump cannot tip over, if necessary you can secure the pump with screws.

General installation
Fig. A Connect the plug of the pump to the receiver, make sure that the plug connections are protected against moisture. Install the receiver in a dry place, with a minimum of 2-meter clearing from the pond.

  • NOTICE! The receiver must not get wet!
  • Plug the receiver into the socket and make sure there is a drip loop in the cord.
  • Make sure that no one can trip over the cord and that the cord cannot be damaged.

Usage of the remote control
The PondECO RC pump is equipped with remote control with which you can easily switch the pump on and off. You can set the pump capacity, and stepped head, thus aiding with consumption.

  • At its lowest settings, the pump will consume less energy but will also have reduced performance and will therefore pump less water around. This may cause the pump to come to a standstill (especially with a lot of head, the use of long pond hoses, and many bends). In that case, increase the pump capacity by one or two steps.
  • This Remote Control is dedicated to the SuperFish PondECO Plus RC 26000 and E 26000 pumps. When used on a different type of pump, this pump will not work or will work incorrectly. Make sure the remote control does not get wet, and store it in a dry place.

Settings PondECO Plus RC 26000 via remote control

Step 1 2 3 4 5 6 7 8 9 10
Pump capacity 15,800 l/h 17, 20 0 l / h 18,000 l/h 18,700 l/h 19,400 l/
20,100 l/h 21,900 l/h 22,600 l/h 23,400 l/h 25,100 l/h
Head 2,6 m 3.0 m 3.2 m 3.6 m 4.0 m 4.6 m 4.6 m 5.0 m 5.4 m 8.2 m
Power 90 Watt 100 Watt 115 Watt 130 Watt 145 Wat 160 Watt 180 Watt 200
Watt 220 Watt 240 Watt

Maintenance

  • **** The pump should be cleaned regularly (minimum twice a year) to ensure trouble-free operation. Scale deposits, in particular, can cause your pump to cease. There is no warranty on failures due to dirty pumps and scale build-up inside the pump caused by improper or lack of maintenance.

  • Remove the plug from the socket before carrying out maintenance!

  • Disconnect the pump from the pond hose and rinse the housing under the tap or garden hose.

  • For proper cleaning and descaling, it is best to use SuperFish Pump & UVC Clean (Art. 07070500), which is available from your dealer.

  • Mix SuperFish Pump & UVC Clean in a large bucket with clean tap water, according to the instructions on the bottle. Immerse the pump into it and leave it there for 24 hours.

  • Take the pump out of the bucket and let it drain before disassembling it.
    Fig. E Open the housing by pressing the latch at the front and back, which will release the upper shell.
    Fig. F Remove the bracket that runs over the pump by unscrewing the 2 screws and taking the pump out of the housing.

  • Dismantle the rotor housing by loosening the 4 screws on the front of the pump and removing the rotor.

  • Brush and clean all parts and the housing thoroughly. Rinse everything with clean tap water and reassemble.

  • Depending on the usage the rotor and rotor housing can get worn out and damaged, this is normal. A new rotor (Art. 07070303) and rotor housing (Art. 07070307) are separately available from your dealer.

  • NOTICE! During periods of frost, you should remove the pump from the pond. Clean and dry the pump well and store it frost-free.

Recycling

This symbol indicates that this product (if it is discarded) may not be disposed of with normal household waste. Instead, it must be handed in at an official collection center (e.g. HWRC). Or can be returned to the dealer when purchasing a similar new product. Follow the applicable rules in your country for the separate collection of electrical and electronic products. Separate collection and recycling are better for the environment, and public health and reduce waste.

Warranty

2 years manufacturer’s warranty on materials and construction defects. Devices must be returned complete with all components, accompanied by an official proof of purchase confirming a purchase date for any warranty claims. Incomplete devices of which parts are missing, and devices without proof of purchase are not eligible for warranty. After receiving and checking, we will determine whether the device will be repaired or replaced. For a device repaired or replaced under warranty, the remaining time of the original warranty period applies. Carefully read the instructions on installation, use, and maintenance. Damage due to incorrect use, damage due to contamination or not cleaning the device, wear and damage to the rotor, and damage to the cord are not covered by the warranty. Always keep the proof of purchase, without proof of purchase the warranty will be void!

Pick-up & Replace Warranty
This PondECO Plus E /RC pump comes with a unique 2-year warranty with 48-hour on-site Pick-up and Replace service.
In the event of a defect, the pump is picked up within 48 hours and immediately replaced free of charge by a new one (from Monday to Friday, with no deliveries on Saturday and Sunday). Subject to proper use and maintenance (regularly descaled and cleaned, cord and rotor not damaged).
To qualify for this 48 hours Pick-Up & Replace Warranty, you must register within 1 month after purchasing the PondECO Plus E or RC pump. To register, simply fill out the enclosed registration form in full and return it with a copy of the purchase to Aquadistri.
If you do not register by the aforementioned deadline, the 48-hour Pick-up and Replace Warranty will not be valid. For any problems during the warranty period, simply contact your dealer.
The Pick-Up & Replace Warranty is only applicable in the Netherlands, Belgium, Luxembourg, Germany, France and the United Kingdom. For residents of other countries the normal warranty applies, for this you need to contact the dealer where the pump was purchased.

https://aquadistri.com/videos/superfish-pond-remote-plus-e-remote-control/

DECLARATION OF CONFORMITY
Dear Sir/Madam. Hereby we, Aquadistri By. declare under our sole responsibility that product(s);
Superfish PondECO plus RC 5000 Superfish PondECO plus RC 10.000
Superfish PondECO plus RC 15.000
Superfish PondECO plus RC 20.000
Suoerfish PondECO plus RC 26.000
art.nr.07070210 art.nr.07070215 art.nr.07070220 art.nr.07070225 art.nr.07070230
Is/are in conformity with the technical requirements of the following European and UK directive(s): the Electric Magnetic Compatibility Directive (EMC- directive: 2014/30/EU: UK: Electromagnetic Compatibility Regulations 2016) the Low Voltage Directive (LVD. 2014/35/EU: UK: Electrical Equipment (Safety) Regulations 2016) the Radio Equipment Directive (RE-D: 2014/53/EU: UK: Radio Equipment Regulations 2017) the Restriction of Hazardous Substance Directive (RoHS-directive: 2011/65/EU: UK: Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012) the Registration. Evaluation. Authorization and restriction of Chemicals Directive (REACH-directive: 1907/65/EU)
And in conformity with the following European harmonized standards: EN 55014-1:2017, EN 301 489-1 V2.2.0, EN 301 489-1 V2.2.2, EN 301 489-3 V2.1.1 EN 60335-1:2012+A11+A13, EN 60335-2-41 :2003+A1+A2, EN62233 :2008 EN 60730-1:2016, EN 62479:2010, EN 300 220-1 V3.1.1, EN 300 220-2 V3.1.1
Test report No.: EMC No. 4349458.50-EMC, 4349458 53. 180501282SHA-002 LVD No. 17043257 004 RE-D No. 4349458.51-RF, 4349458.52-RF, 180501282SHA-001, 180501282SHA-003
Signed by: Dr.ir. J.C.F. van Heeswijk
Function: Compliance manager Aquadistri
Date: 27’h of September 2022 Signature:

Aquadrstri B.V.
Vbetweg 8 4791 EZ. Klundert
The Netherlands
Tel : +31 (0)168-408333
Fax: •31 (0)168-408334
info@aquadistri.com
www.aquadistri.com
Aquadistri B.V. rs part of Aquatic Wholesale Group B.V.
Director R. J. van den Enden Company registration number 23084659
VAT number NL8125.98.5561301

Technical specifications: Pump: 220-240 V/50 Hz.
RC-Receiver: 220-240 V/50 Hz.
RC-Transmitter: DC 12 V, frequent band: 433 MHz.
Maximum Radiated Power <10 dBm = 10 mW.
Date of purchase Dealer stamp
Type Approved Safety
Regular Production Surveillance
www.tuv.com 
ID 1419042825
www.aquadistri.com
09-2022 MH
Vlietweg 8, 4791 EZ Klundert,
The Netherlands, info@aquadistri.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals