DEXIN MAG DX-320HC Coercive Force Meter User Manual

June 1, 2024
DEXIN MAG

DEXIN MAG DX-320HC Coercive Force Meter User Manual

Dear Customers:

Welcome to be our customers. It is great honor for us that you purchase the DEXINMAG (R) Magnetic Measuring Instruments. We provide this User Manual with the instrument. Please read this User Manual carefully before put the instrument into use, which will help you make better use of it.
Please keep this User Manual properly as part of the instrument, so that the operators can refer to it whenever needed.
Although this User Manual has been carefully checked, the flaws cannot be avoided. If there is any ambiguity, please contact XIAMEN DEXING MAGNET TECH.CO.,LTD. Our company does not assume any responsibility for the printing errors and users’ misunderstandings about the User Manual.
Our company has been committed to the continuous improvement of products; the contents of the User Manual are subject to change without notice.
The final interpretation of this User Manual owns to XIAMEN DEXING MAGNET TECH.CO.,LTD.

[Registered Trademark Statements]

The registered trademark which involved in this manual belongs to the trademark holder.

[Copyrights Statements]

The copyright of this User Manual belongs to XIAMEN DEXING MAGNET TECH.CO.,LTD. Without the authorization of our company, all units and individuals are not allowed to copy, plagiarize and modify the contents of this User Manual.

Packing List

Name| Coercimeter
Model| DX-320HC
Quantity| 1 SET
S/N|
Software

version

|

List

| Name| Model| Qua.| Configuration

or Optional

| Remarks
CONTROL UNIT| DX-320HC| 1 SET| √|
FLUXMETER| DX-210B| 1 SET| √|
POWR SUPPLY| DX-2012SD| 1 SET| √|
Test platform support frame|  | 1 SET| √|
Test Platform|  | 1 SET| √|
Software|  | 1 PCS| √| Installed     in

computer

Industry computer| ADVANTECHIPC-510| 1 SET| √|
Monitor| Lenovo 19.5′| 1 SET| √|
Standard Cabinet| 600mm600mm900mm| 1 SET| √|

Optional

| Sample fixture| Customized     according

to samples

| 1 SET| ╳|
Measuring coils| Customized     according

to samples

| 1 SET| ╳| Built in test

platform

Accessories

| Reference sample| Pure iron rod| 1 PCS| √|
Patch Board|  | 1 PCS| √|
Power Line|  | 1 PCS| √|
25pin Connect Line|  | 1 PCS| √|
User Manual|  | 1 PCS| √|
Warranty Card|  | 1 PCS| √|
Packed by: Date:| Recheck by: Date:

Remarks: “√”means standard configuration, and “×”means optional and need extra cost.

Overview

DX-320HC Coercimeter is specialized in measuring the coercivity of soft magnets. The measured samples are soft magnets with shape of strip, bar and sheet, and magnetic components such as relay, electromagnet valve, magnetic head and so on. It can visually evaluate the magnetic change of magnetic components during the workmanship (such as electroplating, annealing and welding); and also be used for magnetic measurement of magnetic label, magnetic anti-forgery ink and cemented carbide.
DX-320HC Coercimeter adopts vibration sample zero flux detection sensor, with high sensitivity and accuracy. It can test sample by operating the panel under the condition of stand-alone machine and also test by upper computer software control.
The test system confirms to GB3656-2008, GB13888-2009 and IEC 60404-7.

Application Fields

  1. Test sample category: soft magnets such as electrical pure iron, precision alloy, martensitic
  2. Test sample shape: strip, sheet and
  3. Directly test the coercivity of soft magnet components such as relay, solenoid value, magnetic head, leakage protector, magnetic label as so on. (Equip with measuring fixture).
  4. Test range:5~1000A/m.
  5. Sample size: maxΦ57mm*200mm,Min:20μm x 1mm x 30mm (equip with customized test platform)

 Measuring Method

Magnetic flux measurement

  1. Adopt gradient magnetic field over zero method. 2.Intelligent change range and digital amplification technology ensure high signal resolution.
  2. Different measuring coils can be changed, the minimum test sample size is 20μm x 1mm x 30mm
  • Magnetic field measurement
  1. Current method: realize by measuring the current of solenoid
  2. Power supply dynamic change range to meet large current output and guarantee high measurement resolution and accuracy.
  3. Magnetic field minimum resolution: 01A/m.

 Hardware Parameters

  1. 4.1 DX-320HC Coercimeter(Main frame)

Instrument adopts ARM control technology, a variety of signal processing algorithm, fast fuzzy algorithm, digital filtering algorithm, intelligent ΔB control technology.
The system supports three measurement modes: fine mode, fast mode and smart mode.

S/N Modes Explanations
1 Fine mode It is the common (preferred) test mode.

2

|

Fast mode

| It is suitable for measuring samples with the same material and the same size, which can greatly reduce the test time;

Instructions and prerequisites:

1. The test platform and cabinet cannot be moved or rotated.

2. Use fine mode to continuously measure the same sample more than 2 times;

3

|

Smart mode

| It has a certain acceleration effect on the tested samples of the same material and size.

Instructions and prerequisites:

1. The test platform and cabinet cannot be moved or rotated.

2.  The electromagnetic environment around the equipment is relatively stable (such as laboratory);

Notes: Press the number key “4” to set the coercivity range, which can improve the test accuracy and speed. Test accuracy: Fine mode >Smart mode >Fast mode;
Test speed: Fast mode >Smart mode > Fine mode;

DX-2012SD POWER SUPPLY

Items Specifications
Output voltage 0~±50V
Output current 1mA~10A (thirteen automatic ranges, dynamic smoothly change

ranges)
Current fineness| < 0.1%×current range
Current stability| Superior to 0.05%

DX-210B Fluxmeter

Items Specifications
Display 4¾ digits
Integral capacity 0.1 µF
Input resistance 100 k、, 10 k, 10 k, 10 k
Range 40mVs, 4mVs、, 0.4 mVs, 0.04mVs
Resolution 0.01, 0.001, 0.0001, 0.00001 mVs

Accuracy

| 1% reading±4uVs(10Hz-10kHz);

±5% reading±4uVs(2Hz-10Hz:10kHz-50kHz);Integrator drift: N/A。

Frequency rang| 2 Hz to 50 kHz

Technical Data

Working Environment

Parameters Specifications
Input power Single-phase 200~240V, 20A, 50Hz
Total power About 2000w
Environment Temperature: 23±5℃; Humidity: 30~75%RH
External magnetic field interference Absolutely avoided
Thermal balance time 10 minutes

System Parameters

Parameters Specifications
Max. Magnetic field 50KA/m (measure general soft magnet components)
Magnetic field resolution 0.01A/m
Measurement range 5-1000 A/m(equip with 3 kinds of coil)
Accuracy ±2%

Repeatability

|

Reference sample

| Superior to ±0.5% (when measure electric pure iron, with size of diameter 10mm, length 100-200mm).
Magnetic components| ±1%,±0.18A/m
Test period| 1min~3min

System Composition

DX-320HC Coercimeter is composed of industry computer, DX-320HC CONTROL UNIT, DX-2021SD POWER SUPPLY, DX-210B Fluxmeter and test platform.

Equipment mainframe

S/N Name Explanations

1

| Solenoid| Wind the multi-layer winding wire on the piecing frame, current through wire to produce

magnetic field in the inner solenoid to magnetize tested soft magnet components.

2

| Detection device| It is composed of motor, transmission mechanism and detection mechanism. The detection mechanism is installed on the transmission mechanism, with the drive of motor, detection mechanism fast and accurately moves along with the linear guide-way to detect the work-piece and send the data to DX-320HC Coercimeter for processing and

displays on the LCD.

3

| Feeding

fixture

| It is composed of pressing module, adjust module and fixture box, which is used for

locating work-piece rapidly and accurately.

Installation Conditions

Parameters Specifications
Input power Single phase 220V±20V,50Hz

Site requirements

| For cabinet: floor space 0.6m*0.6m, height 1.2m, bearing not less than 100kg;

For test platform: floor space 0.4m*1m, height 0.4m, bearing not less than 100kg;

Environment| Temperature: 23±5℃; Humidity: 30~75%RH
External                   magnetic

field interference

| ****

Absolutely avoided

Thermal                      balance

time

| ****

10 minutes

System Connection Diagram

Safety Tips

CAUTION:

To make sure the safety of operator and machine, please make sure checkout the machine according to the following steps before power on the machine.

Checkout before POWER ON

Steps Operations Graphic Remarks

1

| Make sure the power switch on the front panel of all

machines are on the state of off (O:OFF).

| |


2

| Check whether the cables of computer, monitor are

well connected or not.

|  | Please       connect      the       cable

according to relevant manual.



3

| Check whether the cables on rear panel of DX-320HC cabinet are connected correctly or not. Cables between cabinet and test platform are connected correctly or

not.

|  | Please       refer        to                   “System connection diagram in chapter2.


4

| Check whether the input AC voltage is the same as the indicated voltage on the computer, monitor and

instrument.

| ****| For the input voltage of computer and monitor, please refer to

relevant product marks.

POWER ON

To make sure the safety of machine, please power on the machine according to following steps.

POWER OFF

To make sure the safety of machine, please power OFF the machine according to following steps.

Measuring Software

Software interface mainly contains: Menu bar, Graphic display bar, Measure data bar and Parameter input and control bar

Software Parts Set and Functions

Main Menu Functions

Export

| It is used to export the test data which displayed in current measure data bar in EXCEL

format.

Setting

| It is used to set control parameters related to measurement. Users generally do not use it

directly.

Help| It includes Website, Calculator and About.

Graphic Display Bar

It is used to display measured graphic, display the demagnetization curves of two magnetic field directions after finished testing.

Measure Data Bar: Used to display current measure data and measure

Position Functions

First line

| Data ID: display the data S/N of a single measurement. Batch number: filled by user

Hc(A/m): measured coercivity value

Hm(A/m): actual max excitation magnetic field Tester, Date, Remark: filled by user

Data table line| To display the current test data, right-click a row to delete the current test data.

Parameter input and control bar

⑴ Record information

Category Parameters Explanations

Test Parameter Information

|

Sample

| Select according to sample actual situation. “rod” for rod shape and “special-shape” for parts.

Exciting H(A/m)

| Click the drop-down box to select. Note: The excitation magnetic field of the reference sample should be set as 25000A/m, while the maximum magnetic field of other samples should be set according

to the drop-down box.

Estimated Hc(A/m)

| User can select from the drop-down menu according to the rough range of coercivity. If the range of coercivity cannot be predicted, please set “<300” for the test and reset it according to the actual

measured coercivity value after testing.

Test times| Users can set freely according to their needs, and generally set

  1. Record| Batch number| Input batch number
    Parameters| Temperature| Input room temperature
    ---|---|---
    Tester| Input tester
    Remark| Input remarks

Test control button

|

Start test/Not connect

| When the test system is connected normally, “Start test” will be displayed. Click it to test;

When the   system   connection   is   abnormal,   “Not   connect”   is

displayed. In this case, the test cannot be performed. You need to check the wiring or check whether the machine is normally started.

Cancel| Click “Cancel” to cancel the test during testing.

Result processing

|

Sort

| After selecting the results and entering the qualified range of coercivity, the coercivity results not within this range will be marked as red.

Result display

| Display     current     sample     measurement                  result or              selected measurement result.

History data

| It can be searched by measuring time or record parameters;

Record parameters include those entered in “Batch Number”, “Tester” and “Remarks”.

 Measuring Operations

Steps Operations

1. Set measurement parameters

| Select sample type according to sample shape and set “Exciting H”, “Estimated Hc”,

“Test Times”. Among them, the Exciting H for reference sample set as 25000A/m, other samples generally select the max magnetic field to test.

2. Set record parameters| Fill in “Batch number”, “Temperature”, “Tester” and “Remarks.




3. Place the sample

| a. Select fixture according to sample size: on the premise of ensuring that the sample does not protrude the biggest outside diameter of fixture, try to use smaller one. b.Place the sample horizontally at the front end of fixture in the direction with a large length-diameter ratio (or the specified measuring direction), push the slide rod to fix

the sample and push the fixture into the test platform.



4. Adjust fixture selection knob

| Adjust the fixture selection knob on the side of the test platform to the corresponding indicated position according to the selected fixture type (if equipped with large, medium or small).

Note: there are only two effective positions for the knob, one position for the small

fixture, and one position for the medium and large fixture.


5. Click “Start Test”

| Click “Start Test”, the software will automatically save and display test results and curve after finished testing.

Cautions

  1. Please select the sample fixture selection knob on the side of the test platform strictly according to the model of sample fixture (small, medium, large).
    Note: a. There are only two effective positions for the knob, one position for the small fixture, and one position for the medium and large fixture.

  2. If the sample fixture and knob adjustment do not match, it will affect the accuracy and repeatability of the measurement results.

  3. Make sure the size of the sample to be measured is less than the maximum outside diameter of the sample fixture
    Note: If the size of the sample to be measured is larger than the maximum outer diameter of the sample fixture, there may be a collision sound in the measurement process; When the impact sound appears, please immediately press the “Cancel” button on the software operation interface or press the “ESC” button on the lower left corner of the DX-320HC host panel to cancel the test and replace the larger fixture. If the problem cannot be solved, please contact the manufacturer.

  4. It is needed to judge the instrument is qualified or not, please test the reference sample. Magnetic field is 25000A/m, select “Rod” for shape, and test for 3 times, if the deviation from the standard value is less than 2% and the data fluctuation is less than 5 A/m, the equipment is normal. If the above indicators cannot be met, please contact the

  5. When the coercivity range of the tested sample is uncertain, the predicted coercivity range can be set as less than 300, and the appropriate range can be selected according to the test

  6. For samples with small length and diameter ratio, the demagnetization field is large, and it is difficult to magnetization and saturation. The test coercivity is lower than saturation value. At this point, the test results are generally for relative comparison, they can be compared when with the same test conditions. If the higher magnetic field needs to be tested in special case, please contact manufacturer for assistance.

  7. As for the measurement direction of sample, generally choose the direction with larger length and diameter If it is regular square, it can be tested according to the working magnetic circuit direction. If there is any doubt about the working magnetic circuit direction, please contact manufacturer for support.

  8. Do not turn off DX-2012SD directly during the test. It is in emergency, please press ”ESC” on the panel of DX-320HC to quit test then press the switch to power off DX-2012SD.

  9. During the operation of equipment, please do not place articles on the inlet and outlet of the equipment, which may affect the dissipation of the

Common Wrong Operations

  • Following error operations may cause damage to equipment or effect service life of
  1. Do not turn on/off equipment according to operation
  2. When instrument alarm, do not treat according to operation Common error operation is directly power off instrument when alarm.
  3. The test sample size over the maximum diameter range of the test fixture, which cause the vibration coil inside the test platform to hit the test fixture and damage the vibration coil.
  • Following error operations may lead to test (data)
  1. There are metal (magnetic) objects placed around the test platform during
  2. Move the fixture or test platform when instrument in the state of
  3. No suitable test fixture is selected, for example large size test fixture for small size
  4. The sample placement is not standard, mainly in the following cases: the sample is not placed in the front end of test fixture; the sample is not parallel to the axial of the test platform; the sample is not secured during the

The Following shall be Operated under the Manufacture Authorization

  1. Without the authorization of manufacturer, user can not revise the instrument system
  2. Without the authorization of manufacturer, user can not open the cover to maintain the
  3. Without the authorization of manufacturer, user can not re-install the operating system of
  4. Non-professional testers should operate the instrument under the guidance of professional

In case above operations shall be carry out, please contact us in time. Professional engineer in or company will support you. If the user has carried out the above operations without authorization and caused instrument damage, our company will not provide free warranty service (within warranty period).

General Maintenance

Instrument Calibration

DX-320HC Coercimeter is the special equipment and it can only calibrate by professional engineers. We attach one set of reference sample with the machine and together with the report of the sample. When you test the reference sample, if the test data and values in report is over the instrument technical data, please contact the manufacture, we will provide the consulting service in time.

Replace Fuse

The fuse lies under the power socket of the rear panel of the machine. After take out the power line, use the tweezers or directly by hand to take out the fuse and change it with the spare fuse.

Daily Maintenance

  1. If the machine is not used for a long time, please turn on the machine regularly, it is recommended once a week and each time not less than 30
  2. If the machine is used in the production site, it is recommended to clean the dust every month. The method is: open the upper cover and use a vacuum cleaner to clear the dust and metal debris in the chassis.

Common Faults Analysis


S/N Fault description Causes Solutions





1

| ****



Buzzer alarm, “ALARMRESET” on

front panel turn light.

| Test power supply is over current or over voltage.| 1.  Press “ESC” on front panel of DX-320HC to cancel test.

2.  Press “ALARMRESET”” on front panel of DX-2012SD to cancel alarm.

3.  Check the primary wire BN1 between test platform and terminal box is connected well or not.

4.  If the alarm cannot be canceled or it still alarm after above checkout, please turn off the machine and contact

manufacturer.


2

| Instrument does

not work after click “Start Test”.

| DX-320HC is under abnormal code state.| Restart the whole test system, if not solved, please turn off the machine and contact manufacturer.



3

| ****


Test failed

| Sample is too small or induction signal is too weak.| 1.  Check whether the test fixture is suitable or not, the smallest possible fixture should be adopted.

2. Check whether the sample is placed according to step

3 in operations.




4

| Test data is abnormal, repeatability or accuracy is not up

to standards.

| Induction signal is too weak.| 1.  Check whether the test fixture is suitable or not, the smallest possible fixture should be adopted.

2.  Check whether the sample is placed according to step 3 in operations.



5

| When the test platform starts to vibrate, the test

fixture pops up.

| Test sample size is over the maximum size of test fixture.| Select larger diameter test fixture, if the largest fixture can still fail, please contact manufacturer to customize test platform.

Description of Warranty

The warranty period is 18 months (except for fragile parts). It begins on the date of delivery of the product. During the warrant period, our company provides free service except for artificial damage.

Our company is responsible for lifelong repair, and charge appropriately for repair service out of warranty period.5.2  Items Excluded from Free Warranty

The warranty period does not apply to fragile parts.

The warranty period does not apply to parts defect which are due to accidental or error operation.
The warranty period does not apply to defects of product result from disassembling equipment or replacing parts without authorization from Dexing.
The warranty period does not apply to defects of product results from Force Majeure (such as flood, fire, typhoon and other natural disasters and accidents).
The warranty period does not apply to defects of product result from improper or inadequate transport, use and maintenance (such as: damp, corrosion, rotten and mechanical damage).

Appendix 1 Symbol, name and units

S/N Symbol Name Unit Remarks
1 B Magnetic flux density T; mT; Gs
2 φ Magnetic flux Wb; vs
3 H Magnetic field strength A/m; A/cm; Oe
4 I Current A; mA
5 Hc Coercivity A/m; A/cm; Oe

ANNOUNCEMENT:

Although this User Manual has been carefully checked, the flaws cannot be avoided. If there is any ambiguity, please contact XIAMEN DEXING MAGNET TECH. CO., LTD. Our company does not assume any responsibility for the printing errors and users’ misunderstandings about the User Manual.
Our company has been committed to the continuous improvement of products; the contents of the User Manual are subject to change without notice.
The final interpretation of this User Manual owns to Xiamen

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DEXIN MAG User Manuals

Related Manuals