Specifications

  • Model: 16-R1
  • Power Source : 12-V AC/DC Adapter (PS-12DC1) or compatible third-party power source Input Current Draw: less than 190 mA @ 12 VDC, less than 160 mA @ 24 VDC
  • Recommended Mounting: Gooseneck pedestal using included mounting hardware
  • Optional Mounting : 4G LTE Antenna Extension Kit (Model 16-ANTX-1) for alternate mounting

Product Usage Instructions

Installation

  1. Unpack the box and ensure that you have all the items listed in the manual.
  2. Remove the security screws using the L Key and open the unit faceplate for mounting, wiring, and setup.
  • Activation

    • This Ascent unit will not work until the activation process is complete. Please refer to the included Activation Guide for instructions on activating the unit. If you need assistance or have any questions, please contact Summit Control at 972-474-6422.
  • Mounting

    • We recommend mounting the unit on a gooseneck pedestal using the included mounting hardware. If you choose an alternate mounting method, it is essential to purchase and install the 4G LTE Antenna Extension Kit (Model 16-ANTX-1) to ensure a reliable signal.
    • Failure to do so may result in no signal. When mounting the unit to a pedestal, use all four carriage bolts provided. Additionally,leave the hockey puck antenna in place even if using an antenna extension. Lastly, seal all openings created in the enclosure to prevent damage to the unit.
  • Power Source

    • If using the included 12-V AC/DC adapter, connect the wires to the unit as shown in Step 4. Make sure to connect positive to positive and negative to negative when connecting wires to your power source. If you plan to use a third-party power source, verifythat it is compatible with the unit’s electrical specifications mentioned above. Do not exceed 24 VAC/DC as it can damage the unit.
  • Wiring

    • Feed wires through the back of the unit and connect them as shown using the included screwdriver. We recommend using 18-gauge stranded wire for all connections. However, please consult your gate/door opener manual for exact connections as terminals may vary across manufacturers and models. Additional wiring diagrams can be found online.

FAQ

  • Q: Can I use a different power source instead of the included 12-V AC/DC adapter?

    • A: Yes, you can use a compatible third-party power source. Please ensure that the power source you choose meets the unit’s electrical specifications mentioned above and do not exceed 24 VAC/DC to prevent damage.
  • Q: What should I do if I have trouble activating the unit?

    • A: If you encounter any issues during the activation process or have questions, please contact Summit Control at 972-474-6422 for assistance.
  • Q: Is it necessary to mount the unit on a gooseneck pedestal?

    • A: While we recommend mounting the unit on a gooseneck pedestal using the included hardware, you can choose an alternate mounting method. However, if you opt for an alternate mounting, it is crucial to purchase and install the 4G LTE Antenna Extension Kit (Model 16-ANTX-1) to ensure a reliable signal. Failure to do so may result in no signal.
  • Q: What should I do if I need help with wiring connections?

    • A: For assistance with wiring connections, please refer to the wiring instructions provided in the manual or scan the QR code on the next page. If you require further assistance, you can contact Summit Control at 972-474-6422 or email support@summitcontrol.com.

WHAT IN THE BOX

SECURITY-BRANDS-Ascent-R1-Archives-Entry-Telephone-
FIG1

  • Unpack box and make sure you have all items shown here.

Remove security screws

Remove security screws with L Key, and open unit faceplate for mounting, wiring, and setup.

IMPORTANT

  • This Ascent unit WILL NOT WORK until the activation process is
  • COMPLETE! See the included Activation Guide to get this unit activated.
  • If you need help or have any questions, please contact Summit Control at 972-474-6422.

WARNING

  • AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
  • ALWAYS CHECK THAT THE GATE PATH IS CLEAR BEFORE OPERATING!
  • REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED!

pedestal using

  • Mount unit to pedestal using included mounting hardware.
  • (This step may be completed later.)

IMPORTANT

  • We recommend mounting the unit on a gooseneck pedestal using the included mounting hardware.
  • If using alternate mounting, the4G LTE Antenna Extension Kit (Model 16-ANTX-1) should be purchased and installed.

Failure to do so may result in NO SIGNAL!

CAUTION

  • Use all four carriage bolts when mounting the unit to a pedestal. Leave the “hockey puck” antenna in place even if using an antenna extension. Seal all openings created in the enclosure.
  • Failure to follow these instructions can damage the unit!

STOP

  • This is a cellular accessory for a gate or door.
  • An uninterrupted cellular connection CANNOT BE GUARANTEED!
  • An emergency egress or primary entry mechanism SHOULD ALWAYS BE USED! (transmitter, fire box, mechanical release) Consult with your dealer, distributor, and/or system designer for more information.

What’s what?

All important components labeled

SECURITY-BRANDS-Ascent-R1-Archives-Entry-Telephone-
FIG4

  • Unit shown with faceplate fully open. Internal wiring not shown for clarity.

IMPORTANT

  • Verify your power source is compatible with the unit’s electrical specifications below.
  • This product is OK for solar applications.
  • Input 12–24 VAC/DC : no more than 10% beyond this range
  • Current Draw : less than 190 mA @ 12 VDC less than 160 mA @ 24 VDC

P1  : Connect wires to unit as shown in Step 4.

P2 : Connect wires to your power source, making sure you connect positive to positive and negative to negative.

NEED HELP

Connect wires

  • Feed wires through back of unit, and connect as shown usingincluded screwdriver.
  • We recommend using 18-gauge stranded wire for all connections.
  • Consult gate/door opener manual for exact connections.
  • Terminals vary widely across manufacturers and models.
  • Additional wiring diagrams can be found online.

CAUTION

  • If the included 12-V AC/DC adapter will not be used, please go to Page 1 and follow the procedure, Using a Third-Party Power Source.
  • Do not exceed 24 VAC/DC! Failure to choose a compatible power source can damage the unit!

Power Source

Third-Party 12–24-VAC/DC Power Source

SECURITY-BRANDS-Ascent-R1-Archives-Entry-Telephone-
FIG5

STOP

  • Before going forward, double check all does, close and secure unit faceplate. wiring and make sure the unit has power!

  • A wiring diagram for connecting to Wiegand devices can be found below.

  • For connecting accessories not mentioned,

  • please scan the QR code on this page.

  • Make sure the gate path is clear before completing Step 5!

  • Key in temporary code 2012 on keypad and confirm gate opens. If it

  • Before going forward, double check all does, close and secure unit faceplate.

Adding and deleting codes is done through Summit Control and NOT from keypad on unit!

INSTALLATION COMPLETE

  • Now follow the Activation Guide to create an account and begin using Ascent.

Notes

………………………………….

………………………………….

…………………………………

Need More?

  • Use the QR code below to get access to more resources, including how-to videos and additional wiring diagrams for connecting accessory devices.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SECURITY BRANDS User Manuals

Related Manuals