MEAN WELL GSM12E Series 12W AC-DC Reliable Green Medical Adaptor Owner’s Manual
- June 16, 2024
- MEAN WELL
Table of Contents
- MEAN WELL GSM12E Series 12W AC-DC Reliable Green Medical Adaptor
- Product Information
- Product Usage Instructions
- Features
- Applications
- GTIN CODE
- Description
- Model Encoding
- SPECIFICATION
- Derating Curve
- Static Characteristics
- Mechanical Specification
- DC output plug
- Installation Manual
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL GSM12E Series 12W AC-DC Reliable Green Medical Adaptor
Product Information
Specifications:
- Order No.: SAFETY MODEL NO. GSM12E05=P1J USB
- DC Voltage:
- 5V
- 7.5V
- 9V
- 12V
- 15V
- 18V
- 24V
- 48V
- Rated Current:
- 2.4A (for 5V)
- 1.6A (for 7.5V)
- 1.33A (for 9V)
- 1A (for 12V)
- 0.8A (for 15V)
- 0.66A (for 18V)
- 0.5A (for 24V)
- 0.25A (for 48V)
- Rated Power (max.): 12W
- Output Ripple & Noise (max.): 60mVp-p (for 5V, 7.5V, 9V), 80mVp-p (for 12V, 15V, 18V), 100mVp-p (for 24V, 48V)
- Setup, Rise, Hold Up Time: 500ms, 30ms, 16ms/230VAC; 500ms, 30ms, 16ms/115VAC at full load
- Voltage Range: 80 ~ 264VAC, 113 ~ 370VDC
- Frequency Range: 47 ~ 63Hz
- Efficiency (Typ.): 80% (for 5V), 82% (for 7.5V, 9V), 82.5% (for 12V), 84% (for 15V), 85% (for 18V), 85% (for 24V), 87% (for 48V)
- AC Current: 0.4A / 115VAC, 0.2A / 230VAC
- Inrush Current (max.): Cold start 30A / 115VAC, 60A/230VAC
- Leakage Current (max.): Touch current < 100A/264VAC
- Working Temperature: -20°C ~ +70°C (Refer to Derating Curve)
- Working Humidity: 0 ~ 95% RH non-condensing
- Storage Temperature, Humidity: -20°C ~ +85°C, 0 ~ 95% RH non-condensing
- Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, and Z axes
- Safety Standards: TUV BS EN/EN60601-1, BS EN/EN60601-1-11 (3.1 version), IS13252(Part1)/IEC60950-1(for USB only), EAC TP TC 004 approved GSM12E05-USB without BS EN/EN60601-1-11
- Isolation Level: Primary – Secondary: 2 x MOPP
- Withstand Voltage: I/P-O/P: 5656VDC
- Isolation Resistance: I/P-O/P: 100M Ohms / 500VDC / 25/ 70% RH
- LIFE MTBF: 3 years: 100% load 40, 12 hours/day 400Khrs min. MIL-HDBK-217F(25)
- Dimension: 62.2 x 27.4 x 39.7mm (L x W x H)
- Packing: 100g, 90pcs / 10kg / CARTON for cable connection; 76g, 150pcs / 12.5kg / CARTON for USB connection
Product Usage Instructions
Cable Connection:
- Ensure that the power source is compatible with the input voltage range specified in the specifications.
- Connect the adaptor to the power source using the provided cable.
- Connect the other end of the cable to the device you want to power.
USB Connection:
- Ensure that the power source is compatible with the input voltage range specified in the specifications.
- Connect the adaptor to the power source using the provided USB cable.
- Connect the USB end of the cable to a USB port on your device.
Frequently Asked Questions (FAQ):
-
Q: What is the maximum rated power of the adaptor?
A: The maximum rated power of the adaptor is 12W. -
Q: What is the voltage range for the adaptor?
A: The voltage range for the adaptor is 80 ~ 264VAC, 113 ~ 370VDC. -
Q: What is the working temperature range for the adaptor?
A: The working temperature range for the adaptor is -20°C ~ +70°C (Refer to Derating Curve). -
Q: What safety standards does the adaptor comply with?
A: The adaptor complies with TUV BS EN/EN60601-1, BS EN/EN60601-1-11 (3.1 version), IS13252(Part1)/IEC60950-1(for USB only), EAC TP TC 004. -
Q: What is the isolation level of the adaptor?
A: The isolation level of the adaptor is Primary – Secondary: 2 x MOPP. -
Q: What is the dimension of the adaptor?
A: The dimensions of the adaptor are 62.2 x 27.4 x 39.7mm (L x W x H).
Features
- Universal AC input / Full range
- Medical safety approved (2 x MOPP) accroding to BS EN/EN60601-1/BS EN/EN60601-1-11
- Extremely low leakage current
- No load power consumption< 0.075W(<0.1W for 18V/48V)
- Energy efficiency Level VI
- -20~+70°C wide range working temperature
- Class I power (no earth pin)
- Protections: Short circuit / Overload / Over voltage
- Fully enclosed plastic case
- Various DC plug quick adapter accessories available (Plug kit sold separately, please refer to: https://www.meanwell.com/upload/pdf/DCplug.pdf)
- 3 years warranty
Applications
- Blood glucose meter
- Blood pressure meter
- Nebulizer
- Inhaler
- Portable medical device
- Sleep apnea devices
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Description
GSM12E is a highly reliable, 12W wall-mounted style single-output green medical adaptor series, which is compact and convenient for carry. This product is equipped with the standard 2-pin European plug. GSM12E is a class II power unit (no FG), accepting the input range from 80VAC to 264VAC it can satisfy the demands of various types of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra-low leakage current (<100MA), and fitting the medical devices in direct electrical contact with the patients.
With a working efficiency of up to 87% and extremely low no-load power consumption below 0.075W(<0.1W for 18V/48V), GSM12E is compliant with EU ErP and meets CoC version 5 (Except for 18V/48V). The supreme feature allows the adaptor to save energy when it is under either the operating mode or the standby mode. The entire series is approved for international safety regulations; moreover, it adopts the 94V-0 flame retardant plastic case that it can effectively prevent users from electric hazards.
Model Encoding
SPECIFICATION
ORDER NO.
| GSM12E05-
=P1J USB
| ****
GSM12E07- P1J
| ****
GSM12E09- P1J
| ****
GSM12E12- P1J
| ****
GSM12E15- P1J
| ****
GSM12E18- P1J
| ****
GSM12E24- P1J
| ****
GSM12E48- P1J
---|---|---|---|---|---|---|---|---
OUTPUT
| SAFETY MODEL NO.| GSM12E05| GSM12E07| GSM12E09| GSM12E12| GSM12E15|
GSM12E18| GSM12E24| GSM12E48
DC VOLTAGE Note.2| 5V| 7.5V| 9V| 12V| 15V| 18V| 24V| 48V
RATED CURRENT| 2.4A| 1.6A| 1.33A| 1A| 0.8A| 0.66A| 0.5A| 0.25A
CURRENT RANGE| 0 ~ 2.4A| 0 ~ 1.6A| 0 ~ 1.33A| 0 ~ 1A| 0 ~ 0.8A| 0 ~
0.66A| 0 ~ 0.5A| 0 ~ 0.25A
RATED POWER (max.)| 12W| 12W| 12W| 12W| 12W| 12W| 12W| 12W
RIPPLE & NOISE (max.) **Note.3| 60mVp-p| 60mVp-p| 60mVp-p| 80mVp-p|
80mVp-p| 80mVp-p| 80mVp-p| 100mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±3.0%| ±3.0%|
±2.0%| ±2.0%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%| ±1.0%
LOAD REGULATION Note.6| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±3.0%| ±3.0%|
±2.0%| ±2.0%
SETUP, RISE, HOLD UP TIME**| 500ms, 30ms, 16ms/230VAC 500ms,
30ms, 16ms/115VAC at full load
INPUT
| VOLTAGE RANGE Note.7| 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 80%| 82%| 82%| 82.5%| 84%| 85%| 85%| 87%
AC CURRENT| 0.4A / 115VAC 0.2A / 230VAC
INRUSH CURRENT (max.)| Cold start 30A / 115VAC 60A / 230VAC
LEAKAGE CURRENT(max.)| Touch current < 100μA/264VAC
PROTECTION
| OVERLOAD| 110 ~ 200% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
OVERVOLTAGE| 110 ~ 140% rated output voltage
Protection type: Clamp by Zener diode, output short
ENVIRONMENT
| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 0 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 0 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0 ~ 40℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
(Note. 8)
| SAFETY STANDARDS| TUV BS EN/EN60601-1, BS EN/EN60601-1-11 (3.1
version), IS13252(Part1)/IEC60950-1(for USB only), EAC TP TC 004 approved
GSM12E05-USB without BS EN/EN60601-1-11
ISOLATION LEVEL| Primary – Secondary: 2 x MOPP
WITHSTAND VOLTAGE| I/P-O/P:5656VDC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55011 (CISPR11)| Class B
Radiated emission| BS EN/EN55011 (CISPR11)| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55024, BS EN/EN60601-1-2, BS EN/EN61204-3
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 3, 10V/m(80MHz~2.7GHz)
Table 9, 9~28V/m(385MHz~5.78GHz)
EFT bursts| BS EN/EN61000-4-4| Level 3, 2KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line
Conducted susceptibility| BS EN/EN61000-4-6| Level 2, 3V
Magnetic field immunity| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage dip, interruption| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip
25 periods,
95% interruptions 250 periods
OTHERS
| LIFE| 3 years: 100% load 40℃, 12hours / day
MTBF| 400Khrs min. MIL-HDBK-217F(25℃)
DIMENSION| 62.227.439.7mm (LWH)
PACKING| 100g, 90pcs / 10kg / CARTON for cable connection ; 76g, 150pcs
/ 12.5kg / CARTON for USB connection
CONNECTOR| PLUG| See page 4~5; other type available by customer
requested
CABLE| See page 4~5; other type available by customer requested
NOTE|
- All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient.
- DC voltage: The output voltage set at the point measured by the plug terminal & 50% load.
- Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1uf & 47uf capacitor.
- Tolerance: includes set up tolerance, line regulation, and load regulation.
- Line regulation is measured from the low line to the high line at the rated load.
- Load regulation is measured from 10% to 100% rated load.
- Derating may be needed under low input voltage. Please check the derating curve for more details.
- The power supply is considered an independent unit, but the final equipment still needs to confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx.
Derating Curve
Static Characteristics
Mechanical Specification
Cable Connection
USB Connection
DC output plug
- DC plug changeable through:
1. Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
2. Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide below:
https://www.meanwell.com/upload/pdf/DC_plug.pdf.
Example quick adapter accessory:
- Optional DC plug: (Available in customized cable or quick adapter)
Installation Manual
- Please refer to: http://www.meanwell.com/manual.html.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>