Specifications

  • Power Supply: 12-24V DC
  • Max. Power Consumption: 0.2W
  • Channel Q1-Q5 Rated Load: 2.5A
  • Operation Temperature: [temperature range]
  • Acceptable Ambient Relative Humidity: [relative humidity range]

Description
The LED Dimmer DIM-S5m allows for smooth adjustment of LED light intensity within the range of 1 to 100% of the total lighting power. The device can simultaneously control up to 5 LED lights. In the Sinum Central, different lighting conditions can be created for any scene or automation. Communication with the Central is done via wired connection. The module is mounted on a DIN rail.

Components

  • Power LED
  • Communication LED
  • Registration Button
  • SBUS Communication Connector
  • Power Supply Connector
  • LED Light Connector

Note: The power supply voltage for the LED module should be compatible with the voltage used by the LED lights.

Product Usage Instructions

Registering the Device in the Sinum System
To register the device in the Sinum Central, follow these steps:

  1. Go to Settings > Devices > SBUS Devices > + > Identification Mode tab in the Sinum Central.
  2. Activate the Identification Mode.
  3. Hold the registration button on the device for 3-4 seconds.
  4. The corresponding device will be highlighted on the screen.

Identifying the Device in the Sinum System
To identify the device in the Sinum Central, follow these steps:

  1. Go to Settings > Devices > SBUS Devices > + > Identification Mode tab in the Sinum Central.
  2. Activate the Identification Mode.
  3. Hold the registration button on the device for 3-4 seconds.
  4. The device used will be highlighted on the screen.

FAQ

  • Q: What is the maximum load that can be connected to each channel (Q1-Q5) of the DIM-S5m dimmer?
  • A: The DIM-S5m dimmer can handle a rated load of up to 2.5A per channel.
  • Q: What is the acceptable ambient relative humidity for the DIM-S5m dimmer?
  • A: The acceptable ambient relative humidity range for the DIM-S5m dimmer is not provided in the user manual. Please refer to the manufacturer’s specifications or contact their customer support for detailed information.

DIM-S5m LED light dimmers enable smooth change of the light intensity of LED strips in the range from 1 to 100% of the total lighting power. The device support 5 LED strips simultaneously. In the Sinum Central, you can create different lighting conditions for any scene or automation. Communication with the Sinum Central device is done by wire. It is designed to be mounted on a DIN rail.

OVERVIEW

Sinum-DIM-S5m-LED-Dimmer-fig- \(2\)

Description

 Power supply
Communication

  1. Registration button
  2. SBUS communication connector
  3. Power connector
  4. LED strips power connector

ATTENTION! The supply voltage of the LED module should be adjusted to the supply voltage of the LED strip used.

How to register the device in the sinum system

The device should be connected to the Sinum central device using the SBUS connector 2 , and then enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the Settings > Devices > SBUS devices > + > Add device. Then briefly press the registration button 1 on the device. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room.

How to identify the device in the Sinum system

To identify the device in the Sinum Central, activate the Identification Mode in the Settings > Devices > SBUS Devices > + > Identification Mode tab and hold the registration button on the device for 3-4 seconds. The device used will be highlighted on the screen.

Technical data

Power supply 12-24V DC
Max. power consumption 0,2W
Channel Q1-Q5 rated load 2,5A
Operation temperature 5 ÷ 50°C
Acceptable ambient relative humidity <80% REL.H

Notes

TECH Controllers is not responsible for any damages resulting from improper use of the system. The manufacturer reserves the right to improve devices, update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website.

Before using the device for the first time, read the following regulations carefully. Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children. It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.). The device is not water resistant.

The product may not be disposed of to household waste containers. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

EU Declaration of conformity

Tech Sterowniki II Sp. z o.o. ul. Biała Droga 34, Wieprz (34-122) Hereby, we declare under our sole responsibility that the DIM-S5m modul is compliant with Directive :

  • 2014/35/UE
  • 2014/30/UE
  • 2009/125/WE
  • 2017/2102/UE

For compliance assessment, harmonized standards were used:

  • PN-EN 61347-1:2015-09,
  • PN-EN 61347-2-13:2015-04
  • PN-EN 61547:2009
  • PN-EN 61000-3-3:2013-10
  • PN EN 61000-3-2:2019-04
  • PN-EN 55015:2019-11,
  • PN EN 62384:2021-02
  • EN IEC 63000:2018 RoHS

Wieprz, 10.10.2023

The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at www.tech- controllers.com/manuals

www.techsterowniki.pl/manuals

www.tech-controllers.com/manuals

Made in Poland

Service

tel : +48 33 875 93 80 www.tech-controllers.com [email protected]