Specifications
Model | DC Voltage | Rated Current | Current Range | Rated Power |
---|---|---|---|---|
UHP-200A-4.2 | 4.2V | 40A | 0~40A | 168W |
UHP-200A-4.5 | 4.5V | 40A | 0~40A | 180W |
UHP-200A-5 | 5V | 40A | 0~40A | 200W |
Output:
- Line Regulation: N/A (Not specified in the manual)
- Load Regulation: N/A (Not specified in the manual)
- Setup Time: 2000ms at 230VAC, full load
- Rise Time: 200ms at 230VAC, full load
- Hold Up Time (Typ.): 3000ms at 115VAC, 80% load
- DC OK Function: PSU turns on when DC is ok; PSU turns off when DC fails
Input:
- Voltage Range: 90 ~ 264VAC
- Frequency Range: 47 ~ 63Hz
- Inrush Current (Typ.): 85A at 230VAC, cold start
- Power Factor (Typ.): 0.97 at 115VAC, full load; 0.95 at 230VAC, full load
- Efficiency (Typ.): 88%
- AC Current (Typ.): 2.4A at 115VAC; 1.2A at 230VAC
- Leakage Current: N/A (Not specified in the manual)
Product Usage Instructions
Installation
- Ensure that the power supply is disconnected from the power source.
- Connect the input terminals of the power supply to the appropriate AC power source using the provided cables.
- Connect the output terminals of the power supply to your device using the appropriate cables.
- Double-check all connections to ensure they are secure.
Operation
- Ensure that the power supply is connected to a power source.
- Turn on the power supply using the power switch.
- Monitor the DC OK function to ensure that the power supply is functioning properly.
- Adjust the output voltage if necessary using the provided controls.
Maintenance
To ensure the longevity and optimal performance of the power supply, please
follow these maintenance guidelines:
- Regularly inspect the power supply for any signs of damage or wear.
- Keep the power supply clean and free from dust or debris.
- Avoid exposing the power supply to extreme temperatures or humidity.
- Do not attempt to open or repair the power supply yourself. Contact a qualified technician for any repairs or servicing.
Safety Precautions
When using the power supply, please adhere to the following safety
precautions:
- Read and understand all instructions provided in the user manual before operating the power supply.
- Ensure that the power supply is connected to a grounded outlet.
- Avoid touching any exposed electrical components while the power supply is in operation.
- Do not overload the power supply by connecting devices that exceed its rated capacity.
- In case of any abnormal behaviour or malfunction, immediately disconnect the power supply from the power source and contact a qualified technician for assistance.
FAQ
-
Q: What is the voltage range for this power supply?
A: The voltage range for this power supply is 90 ~ 264VAC. -
Q: What is the rated power for each model?
A: The rated powers for each model are as follows:- UHP-200A-4.2: 168W
- UHP-200A-4.5: 180W
- UHP-200A-5: 200W
-
Q: How do I adjust the output voltage?
A: You can adjust the output voltage using the provided controls. Please refer to the user manual for specific instructions on how to adjust the voltage.
User’s Manual
Features
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 seconds
- Low profile:26mm
- Built-in active PFC function
- Fanless design, cooling by free air convection
- Protections: Short circuit / Overload / Over voltage/Over temperature
- Low leakage current<1.0mA
- LED indicator for power on
- 3 years warranty
- Applications
- LED signage display
- Moving sign
- LED channel letter
- LED TV wall
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Description
UHP-200A series is a 200W LED display power solution. The ultra-low profile design allows the height and weight of the sign module to be slim. It greatly simplifies the delivery and installation process. Accounting for high efficiency and energy saving, the series effectively achieves electricity reduction. It is suitable for LED signage display, moving signs, LED channel letter LED TV walls etc.
Model Encoding
SPECIFICATION
MODEL | UHP-200A-4.2 | UHP-200A-4.5 | UHP-200A-5 |
---|
OUTPUT
| DC VOLTAGE| 4.2V| 4.5V| 5V
RATED CURRENT| 40A| 40A| 40A
CURRENT RANGE| 0~40A| 0~40A| 0~40A
RATED POWER| 168W| 180W| 200W
RIPPLE & NOISE (max.) Note.2| 200mVp-p| 200mVp-p|
200mVp-p
VOLTAGE ADJ. RANGE| 4.0~4.4V| 4.3~4.7V| 4.7~5.3V
VOLTAGE TOLERANCE Note.3| ±4.0%| ±4.0%| ±4.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.5%| ±2.5%| ±2.5%
SETUP, RISE TIME| 2000ms, 200ms/230VAC at full load, 3000ms,
200ms/115VAC at 80% load
HOLD UP TIME (Typ.)| 10ms/230VAC 10ms/115VAC
DC OK FUNCTION| PSU Turns on:DC ok; PSU turns off:DC fail
INPUT
| VOLTAGE RANGE Note.4| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≥0.97/115VAC PF≥0.95/230VAC at full load
EFFICIENCY (Typ.)| 88%| 88%| 88.5%
AC CURRENT (Typ.)| 2.4A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.)| Cold start 85A/230VAC
LEAKAGE CURRENT| <1.0mA / 240VAC
PROTECTION
| OVERLOAD| 110~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
SHORT CIRCUIT| Protection type : Hiccup mode, recovers automatically
after fault condition is removed
OVER VOLTAGE| 4.6 ~ 6V| 5 ~ 6.4V| 5.6 ~ 7.1V
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER TEMPERATURE| Protection type : Shut down O/P voltage, recovers
automatically after fault condition is removed
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃(Refer to “OUTPUT LOAD vs TEMPERATURE”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note.5)
| SAFETY STANDARDS| UL 62368-1,TUV BS EN/EN62368-1,CCC GB4943, EAC TP TC
004 approved
WITHSTAND VOLTAGE| I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/
70%RH
EMC EMISSION Note.8| Compliance to BS EN/EN55032 (CISPR32),GB9254,Class
A, BS EN/EN61000-3-2,-3,GB17625.1,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS
EN/EN55035, light industry level (surge 4KV),EAC TP TC 020
OTHERS
| MTBF| 1949.0 K hrs min. Telcordia SR-332 (Bellcore) ; 211.7K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 1675526mm (LWH)
PACKING| 0.42kg; 20pcs/ 11.4kg/0.76CUFT
NOTE|
-
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 C of ambient temperature.
-
Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair wire terminated with a 0.1uf & 47uf parallel capacitor.
-
Tolerance: line regulation and load regulation.
-
Derating may be needed under low input voltages. Please check the static characteristics for more details.
-
Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to an increase in the set-up time.
-
Transient response measures shall be made with 10% load at least.
-
The power supply is considered a component that will be installed into the final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com) -
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment may cause radio interference.
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx.
Block Diagram
- PFC fosc: 65KHz
- PWM fosc: 75~200KHz
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
Mechanical Specification
- CASE NO.: 249A
- Unit: mm
AC Input Terminal(TB1) pin NO. Assignment
Pin No. | Assignment | Terminal | Max mounting torque |
---|---|---|---|
1 | AC/L | (DECA) | 13Kgf-cm |
2 | AC/N | ||
3 |
DC OK Connector(CN1):JST B2B-PH-K-S or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | DC OK +V | JST PHR-2 |
or equivalent
| JST SPH-002T-P0.5S
or equivalent
2| DC COM
DC Output Terminal(TB2,TB3) pin NO. Assignment
Pin No. | Assignment | Terminal | Max mounting torque |
---|---|---|---|
1,2 | -V | (MW) |
TB-HTP-200-40A
| 8Kgf-cm
3,4| +V
Function Manual
The internal circuit of DC ok
Contact Close | PSU turns on | DC ok |
---|---|---|
Contact Open | PSU turns off | DC fail |
Contact Rating(max.) | 10Vdc/1mA |
Installation
-
Operate with additional aluminium plate
To meet the“Derating Curve” and the “Static Characteristics”, the UHP-200A series must be installed onto an aluminium plate(or a cabinet of the same size) on the bottom. The size of the suggested aluminium plate is shown below. To optimize thermal performance, the aluminium plate must have an even and smooth surface (or be coated with thermal grease), and the UHP-200A series must be firmly mounted at the centre of the aluminum plate. -
For heat dissipation, at least 5cm installation distance around the PSU should be kept, shown as below:
User’s Manual
Documents / Resources
| MEAN
WELL UHP-200A Series 200W Single Output with PFC
Function
[pdf] User Manual
UHP-200A Series 200W Single Output with PFC Function, UHP-200A Series, 200W
Single Output with PFC Function, Single Output with PFC Function, Output with
PFC Function, PFC Function, Function
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>