WaveLinx SWPD PRO Outdoor Fixture High-Low Mount Sensor User Guide
- June 16, 2024
- WaveLinx
Table of Contents
- SWPD PRO Outdoor Fixture High-Low Mount Sensor
- Product Features
- Overview
- Product Features & Benefits
- Order Information
- Product Specifications
- Dimensional Details
- Mountig Height
- Installation
- Field of View – Low Mount
- System Diagram:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PRO Outdoor Fixture Mount Sensor
SWPD PRO Outdoor Fixture High-Low Mount Sensor
Project: ……………………………………….
Catalog #: ……………………………………
Type: ………………………………………..
Prepared by: ………………………………..
Notes: ………………………………………..
Date: ……………………………………….. Interactive Menu
- Order Information page 2
- Additional Resources page 4
- Connected Systems page 7
- Product Warranty
WaveLinx
PRO Outdoor Fixture
High / Low Mount Sensor (SWPD)
Motion and closed loop daylighting including field installed shield
Typical Applications
Outdoor • Parking areas • Pathways
Product Certification
- Meets latest ASHRAE Standard 90.1 requirements
- Meets latest IECC requirements
- Meets latest CEC Title 24 requirements
Product Features
Compatibility
Overview
The outdoor (high and low mounted) sensors are an integral part of the
WaveLinx connected lighting system and offer passive infrared (PIR) occupancy
and a photocell for closed loop daylight sensing. WaveLinx PRO outdoor sensors
offer installation heights up to 40 feet and have coverage patterns up to 5000
square feet (see sensor specifications – field of view). When part of WaveLinx
PRO, the sensor operates on a wireless mesh network based on IEEE 802.15.4
standards.
The sensors offer simple tool-less integration into WaveLinx PRO outdoor light
fixtures equipped with the 4-pin Zhaga Book 18 compliant socket. Once
installed, sensors receive power from their co-located light fixture with no
batteries to replace. The sensor in combination with the WaveLinx PRO Mobile
application allows you to gain considerable energy savings from occupancy and
daylight sensing lighting control. The WaveLinx PRO Mobile application allows
you to map the sensor to any area or control zone, select occupancy or
vacancy, occupied and unoccupied light levels and set the hold time.
Product Features & Benefits
- Models suitable for High (up to 40ft / 45ft major motion) and Low (up to 15ft) applications
- Out of the box functionality (on at dusk, off at dawn, occupied to 100%, unoccupied to 50%)
- Passive Infra-Red (PIR) motion sensor with coverage up to 5000 square feet
- Integrated photocell for closed loop daylight harvesting
- Software configurable settings with WaveLinx PRO Mobile application
- Simple tool-less twist lock fixture connection via 4-pin Zhaga Book 18 socket
- IP66 rating for outdoor site and indoor environments
- Energy calculations available through WaveLinx CORE
Order Information
WaveLinx PRO Outdoor Fixture Mount Sensors are accessories to the WaveLinx
connected lighting (WCL) system and requires a WaveLinx Area Controller (WAC)
for full functionality.
WaveLinx PRO Outdoor Fixture Mount Sensors are used to provide occupancy and
daylight dimming to spaces from the outdoor light fixture.
For energy code compliance, additional sensors may not be required.
……………………………………..
Catalog Number
Catalog # | Description |
---|---|
SWPD4-WH | WaveLinx PRO Outdoor Fixture – Low Mount Sensor, White, 7 – 15ft |
(2.1 – 4.5m)
SWPD4-BZ| WaveLinx PRO Outdoor Fixture – Low Mount Sensor, Bronze, 7 – 15ft
(2.1 – 4.5m)
SWPD4-BK| WaveLinx PRO Outdoor Fixture – Low Mount Sensor, Black, 7 – 15ft
(2.1 – 4.5m)
SWPD5-WH| WaveLinx PRO Outdoor Fixture – High Mount Sensor, White, 15 – 40ft
(4.5 – 12.2m)
SWPD5-BZ| WaveLinx PRO Outdoor Fixture – High Mount Sensor, Bronze, 15 – 40ft
(4.5 – 12.2m)
SWPD5-BK| WaveLinx PRO Outdoor Fixture – High Mount Sensor, Black, 15 – 40ft
(4.5 – 12.2m)
Notes
For use with outdoor light fixtures equipped with the WaveLinx PRO Zhaga
compliant 4-pin socket only.| Notes
When used as a component in the WaveLinx connected lighting system, WaveLinx
PRO system design best practices (including WaveLinx Area Controller
placement, line of sight distances, number of hops, etc.) must be followed.
For outdoor applications, the WaveLinx Area Controller should be located
inside a conditioned building with a line of sight (LOS) through a window to
an outdoor sensor (preferably 2-3 sensors) within the range specified below:
LOS through a window: Best practice: 160ft (49m) – tinting / shade reduce
range by 20ft (6m)
No direct LOS, through concrete (up to 7in thick): Best practice: 40ft (12m)
High mount models accommodate mounting height to 45ft (13.7m) for major motion
(vehicles, fork trucks, etc.) – may not detect minor motion of people
depending on conditions.
Required Accessories
All WaveLinx connected lighting (WCL) system accessories require at least one
WaveLinx Area Controller (WAC) for communications.
Ensure the bill of material includes one of the following components.
……………………………………..
Catalog Number
Catalog Number | Description |
---|---|
WAC2-POE | WaveLinx Area Controller G2, PoE powered |
WAC2-120 | WaveLinx Area Controller G2 with 120VAC to PoE Injector |
Optional Accessories
For connection to 120VAC outlets.
……………………………………..
Catalog Number
Catalog Number | Description |
---|---|
WPOE2-120 | 120VAC to PoE Injector |
Product Specifications
Mechanical
Size: Base Diameter 3.2” (82mm) Height: 1.6” (41mm)
Weight: 0.20 lbs (0.10 kg)
Environment:
-
Operating temperature: -40°F to 131°F (-40°C to 55°C)
Note: WaveLinx Area Controller should be installed in an indoor conditioned envirionment, preferably with line of sight through a window to one or more WaveLinx PRO wireless devices
Note: Sensor passive infrared (PIR) performance may become exceedingly sensitive below -4°F (-20°C) -
Storage temperature: -40°F to 158°F (-40°C to 70°C)
-
Relative humidity operating: 0% to 95% non-condensing
-
Default behavior intended for outdoor use only
Mounting: Fixture mount
Mounting Height: High bay up to 40ft (12m) and Low bay up to15ft (5m)
Color: White, Bronze and Black colors available
Housing: UV stabilized plastic
Ingress protection: IP66
Light Sensor Detector Shields: Field configured shield included
Daylighting Installation:
- Ensure that sensor is not looking directly at artificial light
- Ensure that sensor is not obstructed
Electrical
Input Requirements: Fixture connection via 4-pin Zhaga Book 18 socket
Software Specifications
- Any number of sensors can be mapped to any number of zones
- Mobile app configuration for Occupancy/Vacancy
- Remote Hold Time settings fully configurable via mobile app
- Mobile app configuration of Occupied and Unoccupied light levels
- Energy calculations available through WaveLinx CORE
Wireless Specifications
Radio: 2.4GHz
Standard: IEEE 802.15.4
Transmitter Power: + 8dBm
Range: Sensor to sensor; 160ft (49m) LOS (best practice)
System Performance
Maximum number of nodes supported: 200 per WaveLinx Area Controller (best
practice 150 devices)
**Standards/Ratings***
- cULus Listed – Energy Management Equipment (UL916)
- FCC Part 15/ECES-003
- Meets latest ASHRAE Standard 90.1 requirements
- Meets latest IECC requirements
- Meets latest CEC Title 24 requirements
Warranty
Five year warranty standard
Dimensional Details
Mountig Height
Installation
Both the SWPD4 and SWPD5 easily install into WaveLinx PRO-ready LED fixtures equipped with Zhaga Book 18 4-pin sockets. Sensor connection is enabled via the simply twist-lock connection and provides immediate out of the box functionality.
Field of View – Low Mount
System Diagram:
This diagram shows the main components of the WaveLinx connected lighting
system with CAT and PRO devices.
The PRO devices communicate using wireless mesh technology based on the IEEE
802.15.4 standard. A PoE LAN connection for each WaveLinx Area Controller
(WAC) is required for power and data access to the building lighting network.
The CAT devices communicate over the category 5 based communication bus and
control the light fixtures using a relay (on/off) and 0-10V output
(dim/raise).
WaveLinx Area Controllers (WAC) communicate with WaveLinx CORE Apps over the
Ethernet network.
View WaveLinx Network and IT Guidance Technical Guide Control Systems
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2023 Cooper Lighting Solutions
All Rights Reserved.
Specifications and dimensions subject to change without notice.
PS503094EN
September 2023
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>