WaveLinx SIM-C-V CAT Sensor Interface Module Instruction Manual
- June 1, 2024
- WaveLinx
Table of Contents
WaveLinx CAT
Sensor Interface Module
SIM-C-V
Installation Instructions
www.cooperlighting.com
SIM-C-V CAT Sensor Interface Module
WARNING
IMPORTANT: Read carefully before installing product. Retain for future
reference.
Failure to comply with these instructions may result in serious injury
(including death) and property damage.
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation
and maintenance of this product must be performed by a qualified electrician.
This product must be installed in accordance with the applicable installation
code by a person familiar with the construction and operation of the product
and hazards involved.
Before installing or performing any service, the power MUST be turned OFF at
the branch circuit breaker. According to NEC240-83(d), if the branch is used
as the main switch for a fluorescent lighting circuit, the circuit breaker
should be marked with “SWD”. All installations should be in compliance with
the National Electric Code and all state and local codes.
Risk of Fire and Electric Shock- Make certain power is OFF before starting
installation or attempting any maintenance. Disconnect power at fuse or
circuit breaker.
Risk of Burn- Disconnect power and allow fixture to cool before handling or
servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
DISCLAIMER OF LIABILITY : Cooper Lighting Solutions assumes no liability
for damages or losses of any kind that may arise from the improper, careless,
or negligent installation, handling or use of this product.
NOTICE: Product/component may become damaged and/or unstable if not
installed properly.
ATTENTION Receiving Department : Note actual fixture description of any
shortage or noticeable damage on delivery receipt. File claim for common
carrier (LTL) directly with carrier. Claims for concealed damage must be filed
within 15 days of delivery. All damaged material, complete with original
packing must be retained.
Note: Specifications and dimensions subject to change without notice.
NOTICE: All new wiring must be fully verified before applying power.
NOTICE: Designed for indoor installation and use only. 0-10V Dry location
rated.
Warranties and Limitation of Liability
Please refer to
www.cooperlighting.com/global/resources/legal
for our terms and conditions.
FCC Statement
• This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Note: The grantee is not responsible for any changes or modifications not
expressly approved by the party responsible for compliance. Such modifications
could
void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a commercial installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off an on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment must be installed and operated in
accordance with provided instructions and the antenna(s) used for this
transmitter must be installed to provide a separation distance of at least 20
cm from all persons.
ISED RSS
This device complies with Industry Canada’s licence-exempt RSSs. Operation is
subject to the following two conditions: (1) This device may not cause
interference; and (2) This device must accept any interference, including
interference that may cause undesired operation of the device.
General Information
Overview
The Sensor Interface Module is an integral part of the WaveLinx connected
system and provides network addressability to a variety of Greengate dual tech
sensors. The sensors are powered by the SIM module. A limited configurable
options for sensor parameters are available through WaveLinx CAT mobile app.
Plenum Rating
Most of the components in this system are intended to be mounted above the
ceiling tiles, in an area that could be intended for air handling.
Note: The components do not meet the plenum rating standards for Chicago
without additional measures.
Compatible Greengate Sensor Catalog Numbers
- OAWC-DT-120W
- OAWC-DT-120W-R
- OAC-P-0500-R
- OAC-P-1500
- OAC-P-0500
- ONW-D-1001-SP-W
- ONW-P-1001-SP-W
- OAC-DT-0501
- OAC-DT-0501-R
- OAC-DT-1000
- OAC-DT-1000-R
- OAC-DT-2000
- OAC-DT-2000-R
- OAC-P-1500-R
- OAC-U-2000
- OAC-U-2000-R
Specifications
Power | Cat5e Bus Powered |
---|---|
Installation | Wall mount with mounting tabs |
Size | 1.28″ W x 3.34″ H x 1.5″ D (58mm x 85mm x 38mm) |
Mobile App | Connects with WaveLinx CAT mobile app |
Environmental Specifications | • Operating Temperature Range: 32°F to 104°F |
(0°C to 40°C)
• Storage Temperature Range: 22°F to 158°F ( -30°C to 70°C)
• Relative Humidity 5% to 85% non-condensing
• For indoor use only
Standards| • cULus Listed
• FCC Part 15, Part A
• Meets ASHRAE 90.1 – 2019 requirements
• Meets IECC – 2021 requirements
• Meets Title 24 – 2019 requirements
Wall Mounting
Secure the module with two (2) M4 size screws on the mounting surface.
Sensor Interface Module Installation
- Locate a convenient spot on the wall near the ceiling.
- Use Size 4 screws to secure the module on the mounting surface.
- Connect the SIM module via RJ45 ports, with other WaveLinx CAT devices in the local network using CAT5 cables. (If this module is an end unit on the network, insert termination plug in the second RJ45 port.
NOTICE: All new wiring must be fully verified before applying power.
NOTICE: Designed for indoor installation and use only. Dry location
rated.
Wiring Diagram
LED Definitions
State | Event | Blink Pattern |
---|---|---|
0cc Sensor Enabled | 0cc Sensor Disabled | |
Out of Box | N/A | N/A |
Connected (Distributed Mode) | Motion Detected | Blue for 300 ms; OFF for 2.7 s. |
Repeat every 30 s when input line is high (i.e., blink at the same time when
occ report is sent)| Blue for 1 s; OFF for 1 s; Repeat independent of motion
Connected (Network Mode)| Motion Detected| White for 300 ms; OFF for 2.7 s.
Repeat every 30 s when input line is high (i.e., blink at the same time when
occ report is sent)| White for 1 s; OFF for 1 s; Repeat independent of motion
Identify / Reverse Identify| N/A| Magenta for 1 s; OFF for 1 sec Repeat for
identify duration
Firmware Update| N/A| Cyan for 1 s; OFF for 1 sec Repeat for update duration
Bootloader Mode| N/A| Solid Green for the duration of bootloader mode
(Blinking green during image swap)
Reset| Reset Button Pressed| • Button pressed <1 s: OFF If button is released
before 1 s, no reset occurs
• Button pressed >= 1 s: Blue for 500 ms; OFF for 500 ms; Repeat If button is
released before 5 s, soft reset begins
• Button pressed >=5 s: Yellow for 500 ms; OFF for 500 ms; Repeat If button is
released before 10 s, factory reset begins
• Button pressed > 10 s: OFF No reset occurs
If still having trouble, call Technical Services at 1-800-553-3879
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
www.cooperlighting.com
For service or technical
assistance: 1-800-553-3879
Canada Sales
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
F: 905-501-3172
© 2023 Cooper Lighting Solutions
All Rights Reserved
Publication No. IB50340223
July 2023
Cooper Lighting Solutions is a registered trademark.
All trademarks are property of their respective owners.
Product availability, specifications, and compliances are subject to change
without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>