WHITE KNIGHT PFA030 Pumps Owner’s Manual
- June 16, 2024
- WHITE KNIGHT
Table of Contents
WHITE KNIGHT PFA030 Pumps
Product Information
Specifications & Performance
Model | PFA030 | PFASD030 |
---|---|---|
Max Flow Rate* | 25.7 lpm (6.79 gpm) | 29.6 lpm (7.82 gpm) |
Displacement Per Cycle* | 0.089 liters (0.024 gal) | 0.089 liters (0.024 gal) |
Cycles per min | 336 max | 294 max |
Air Connection | 1/4 in | 1/4 in |
Weight | 2.4 kg (5.29 lb) | 2.4 kg (5.29 lb) |
Suction Lift* | 3 m (10 ft) | Flooded suction |
Sound Pressure** | 69.54 dB(a) at 100 psi 50 CPM | 66.58 dB(a) at 100 psi max |
CPM
Power**| 58.44 dB(a) at 100 psi 50 CPM| 65.52 dB(a) at 100 psi max CPM
- May vary by configuration or system. Suction lift diminishes over time. Recommended installation level less than 3 ft above source. To calculate displacement, divide flow rate by CPM.
- Sound measured following ISO9614-2:1997.
- Dry-run capable PFASD030 pumps require flooded suction and may have a reduced warranty. Contact support for details.
Product Usage Instructions
Installation
Before installing the White Knight PFA030 pump, please ensure you have read
and understood the installation requirements and setup instructions provided
in the manual. The installation process involves the following steps:
- Identify a suitable location for the pump installation, keeping in mind the recommended installation level should be less than 3 ft above the source.
- Ensure the pump is securely mounted and properly aligned.
- Connect the air supply to the 1/4-inch air connection.
- Ensure the pump is connected to the appropriate fluid delivery system.
- Verify that all connections are tight and secure.
Control & Monitoring
The White Knight PFA030 pump offers control and monitoring capabilities for
enhanced functionality. To control and monitor the pump, follow these steps:
- Connect the pump to a compatible control system using the appropriate connectors and cables.
- Follow the instructions provided by the control system manufacturer to set up and configure the pump control parameters.
- Monitor the pump performance and adjust the control settings as needed to meet your specific requirements.
Ordering Instructions
If you need to order additional parts or accessories for your White Knight
PFA030 pump, please follow these instructions:
- Refer to the ordering section in the manual for a list of available parts and accessories.
- Contact our customer support team at the provided phone number or website to place your order.
- Provide the model number and any specific requirements or quantities for the parts or accessories you wish to order.
- Complete the ordering process as instructed by our customer support team.
Pump Service
Regular maintenance and servicing of your White Knight PFA030 pump is
important to ensure optimal performance and longevity. Follow these guidelines
for pump service:
Rebuild Kits & Parts
If you need to replace worn-out or damaged parts of your pump, you can order
rebuild kits and individual parts. Follow these steps:
- Refer to the rebuild kits and parts section in the manual for a list of available kits and parts.
- Contact our customer support team at the provided phone number or website to place your order.
- Provide the model number and any specific requirements or quantities for the rebuild kits or parts you wish to order.
- Complete the ordering process as instructed by our customer support team.
Return Pump for Service
If your pump requires servicing or repair, follow these steps to return it:
- Contact our customer support team at the provided phone number or website to initiate the service process.
- Provide the model number and a detailed description of the issue you are experiencing with the pump.
- Follow the instructions provided by our customer support team to package and ship the pump for service.
- Once the pump is received, our service technicians will diagnose and repair the issue.
Warranty & Accessories
The White Knight PFA030 pump comes with a warranty to ensure customer
satisfaction. Additionally, there are various accessories available to enhance
the functionality of the pump. For warranty information and details on
available accessories, please refer to the warranty and accessories section in
the manual.
FAQ
- Q: Can the PFASD030 pump be used without flooded suction?
A: No, the PFASD030 pump requires flooded suction for proper operation. Using it without flooded suction may result in reduced warranty coverage. Please contact our support team for more information.
Dear valued customer,
Thank you for purchasing a White Knight PFA030 pump.
- Our dedicated team designs products to meet your exacting specifications with a demonstrated commitment to quality that goes beyond mere words and fancy slogans.
- Our patented designs offer a variety of size and material options to meet stringent requirements of high-pressure chemical delivery systems, high-temperature re-circulation processes, chemical reclaim and bulk transport applications, slurry systems, and more. Our safe, reliable products offer superior performance, optimized efficiency, and simplified maintenance.
- White Knight is able to provide the highest quality fluid handling products through controlled, consistent in-house engineering and manufacturing. Through continued significant investments in engineering and manufacturing, we lead the industry with new technologies and products.
- White Knight has received numerous awards for innovation and manufacturing programs. We rigorously manage our quality assurance processes to ensure consistency and reliability. Our quality controls include strict cleanliness procedures and consistent manufacturing processes. For example, high-purity product assembly, testing, and packaging is performed in a Class 100 cleanroom.
- Please peruse this manual before installing your White Knight product. It details installation requirements and setup instructions, and provides additional information and accessories for enhanced functionality.
- Our team has gone to great lengths to ensure our products serve your needs and meet your requirements.
- Further, we provide the highest quality products at the best value, and we back them up with excellent warranties and world class support.
Thank you for your confidence and trust in White Knight products.
Sincerely,
White Knight Fluid Handling
Product Information
Specifications & Performance
Model | PFA030 | PFASD030 |
---|---|---|
**Max Flow Rate*** | 25.7 lpm (6.79 gpm) | 29.6 lpm (7.82 gpm) |
Displacement **Per Cycle*** | 0.089 liters (0.024 gal) | 0.089 liters |
(0.024 gal)
Cycles per min| 336 max| 294 max
Air Connection| 1/4 in| 1/4 in
Weight| 2.4 kg (5.29 lb)| 2.4 kg (5.29 lb)
**Suction Lift*| 3 m (10 ft)| Flooded suction
Sound| Pressure****| 69.54 dB(a) at 100 psi 50 CPM
66.58 dB(a) at 100 psi max CPM
Power**| 58.44 dB(a) at 100 psi 50 CPM
65.52 dB(a) at 100 psi max CPM
- May vary by configuration or system. Suction lift diminishes over time. Recommended installation level less than 3 ft above source. To calculate displacement, divide flow rate by CPM.
- Sound measured in accordance with ISO9614-2:1997.
- Dry-run capable PFASD030 pumps require flooded suction and may have reduced warranty. Contact support for details.
Max Fluid Temperature | 100°C (212°F) |
---|---|
Environmental Temperature | min: 0°C (32°F) max: 50°C (122°F) |
Max Supply Air Pressure | 7 Bar (100 psi) |
Min Startup Air Pressure | 1.4 bar (20 psi) |
Fluid Path Materials | PTFE, PFA |
Non-Fluid Path Materials | PTFE, PFA, PP |
Stroke Detection | Fiber optic with or without D10 sensor |
--- | --- |
Leak Detection | Fiber optic with or without sensor, or conductivity |
Electronic Control | CPC, CPT, or custom. Call for details. |
PFA030 Performance
How to Read Charts
Draw a horizontal line at your discharge pressure and vertical line at desired
flow rate. At line intersect, estimate required air pressure, resultant cycle
rate and air consumption.
PFASD030 Performance
Example
At 2 Bar (30 psi) discharge pressure and 60 psi supply pressure, PFA030 pumps
provide 15 lpm (4 gpm) flow rate. They would cycle at ~185 CPM, and exhaust 12
SCFM of air.
Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.
Temperature Limits
Dimensions
Dimensions in [mm] in
Bill of Materials
PFA030 BILL OF MATERIALS
Item| Part| Description| Qty.
1| 1125-TE-0017| Pump Body| 1
2| 2127-EP-0020| Head, Right| 1
3| 2127-EP-0021| Head, Left| 1
4| 14300-PF-0016| Bellows Assembly| 2
5| 5143-MP-0001| Seal, Shaft| 2
6| 5144-PF-0024| Shaft| 1
7| 4140-TE-0001| Top Check Plug| 2
8| 4142-MP-0004| Cage, Check| 2
9| 4135-MP-0006| Seat, Check| 2
10| 4100-MP-0004| Ball, Check, 1/2″| 4
11| 14200-NP-0006| Plate, Base, Assembly| 1
12| 10040-TE-0003| Plug, NPT, 1/4″| 2
13| 10040-TE-0006| 5/8″ Plug Short| 2
14| 8100-PF-0002| Cap, End, Single Probe Dual Detect| 2
15| 3200-VI-0001| Diaphragm, .782| 2
16| 6150-UH-0001| Seat, QEV Exhaust| 2
17| 10080-VI-016-75| O-ring, 016 X .070| 2
18| 6150-NP-0007| Cap, Muffler, QEV| 2
19| 6140-FP-0002| Baffle Porous Poly QEV| 4
20| 6140-PP-0004| Mesh, QEV 04 & 05| 6
21| 7200-PF-0003| Body, Flaretek®, 1/2″| 2
22| 7210-PF-0003| Nut, Flaretek®, 1/2″| 2
23| 14300-MP-0031| Bellows Assembly, Single Probe Dual Detect| 1
24| 6090-UH-0003| QEH Body, 05| 2
25| 14700-XX-0006| Stroke Detect Fiber Optic Assembly With Wire Cutter| 2
Leak Detect
Part| Description
14600-XX-0009| LF0| 15 ft fiber optic cable with no amplifier
14600-XX-0010| LF1| 15 ft fiber optic cable with D10 amplifier
14600-XX-0011| LF2| 25 ft fiber optic cable with no amplifier
14600-XX-0012| LF3| 25 ft fiber optic cable with D10 amplifier
14600-XX-0031| LC0| 15 ft conductivity cable
14600-XX-0040| LC1| 25 ft conductivity cable
Stroke Detect
Part| Description
14700-XX-0021| SFS0| 15 ft fiber optic cable with no amplifier SFS0
14700-XX-0022| SFS1| 15 ft fiber optic cable with D10 amplifier SFS1
14700-XX-0023| SFS2| 25 ft fiber optic cable with no amplifier SFS2
14700-XX-0024| SFS3| 25 ft fiber optic cable with D10 amplifier SFS3
14700-XX-0025| SFD0| 15 ft fiber optic cable with no amplifier SFD0
14700-XX-0026| SFD1| 15 ft fiber optic cable with D10 amplifier SFD1
14700-XX-0027| SFD2| 25 ft fiber optic cable with no amplifier SFD2
14700-XX-0028| SFD3| 25 ft fiber optic cable with D10 amplifier SFD3
Installation
Precautions
-
Handling
Do NOT lift the pump by fibre optic cables, quick exhaust valves nor air tubing. -
Installation Orientation
PFA030 pumps must be installed in an upright position. The check valves are actuated by gravity and/or flow, and they will not seat if the pump is not upright. -
Timer Mode
PFA030 pumps require an end-of-stroke detection mechanism (pressure switch) to prevent over-stroking in timer mode. Operating a PFA030 in timer mode without stroke detection will void the pump warranty. -
Required Air Flow (Shuttle Valve)
PFA030 pumps require 1/4 in minimum orifice with unrestricted airflow. -
Required Air Flow (Solenoid Valve)
PFA030 pumps require a 0.75 Cv solenoid. Using a reduced Cv will reduce flow rates. Using a valve with more than 20% greater Cv will change operating parameters, reduce pump life and void the warranty. -
Under Supply of Air
PFA030 pumps operate erratically or stall when the air supply is insufficient. Ensure the use of air supply pressures higher than averaged air consumption lines in performance charts. Air supply lines and fittings must meet minimal inner diameter requirements shown in the installation instructions. -
Air Supply Pressure
Operating PFA030 pumps ~35% below max air pressure may significantly extend pump life. PFA030 pumps require 20 psi minimum air pressure. Operation above 7 Bar (100 psi) may damage the pump and void the warranty. -
Suction Lift
PFA030 pumps have an initial suction lift capacity of 3 ft. For best results minimize suction lift. -
Liquid Inlet/Outlet Connections
PFA030 liquid ports are not NPT nor any other standard. The use of connectors other than those supplied by White Knight will damage the pump and void the warranty. -
Liquid Line Restriction
PFA030 pumps may be controlled by closing liquid outlet lines. However, restricting liquid supply lines increases wear and should be avoided. Do NOT pump against a closed liquid inlet. It will damage the pump and void the warranty. -
Running Dry
PFA030 pumps use the pumped liquid to lubricate their shafts. The pumps will cycle faster and wear more than normal when run dry, which may cause damage and loss of self-prime abilities. Standard models should not be run dry after start-up and are not warranted under dry run conditions. Dry-run capable PFASD030 models may run dry for short periods. The warranty of dry-run models is one year. Extended warranties are available. -
Pulse Dampener with Shuttle Valve
Air supply pressure to PFA030 pumps should be at least ten psi higher than the liquid line pressure when using a pulsation dampener. Failure to do so may cause erratic operation. -
Cross Contamination
PFA030 pumps use porous material that may retain chemicals. Take precautions to avoid cross-contamination.
Warnings
-
Pressurized Material
Pumps in use contain pressurized materials. Eliminate liquid and air pressure via shut-off valves before the pump is serviced or removed from the system. -
High Temperature
Heat may transfer to exterior surfaces when pumps operate with high- temperature fluids. Avoid direct contact with the pump when high-temperature fluids are present. -
Hazardous Chemical
Use appropriate personal protective equipment when handling the pump. Reference Material Safety Data Sheet (MSDS) for information specific to your chemicals. -
Loud Noise
Pump exhaust air contributes to work area noise levels. Only operate pumps with approved muffler media, and use ear protection in noisy conditions.
Advantages
-
Head Pressure / Dead-Head
PFA030 pumps can be controlled by adjusting their liquid outlet pressures and can be installed with head pressures up to dead-head (e.g. equal liquid and air pressures) with no damage to the pump. -
Thermal Cycling
PFA030 pumps require no maintenance when operated within their performance range, even in thermal cycling applications.
Environment & System
-
Oversized Inlet Line
Pumps operate optimally with liquid inlet lines larger than the liquid outlet lines. This reduces strain on the bellows and may reduce pulsation in the pump outlet. -
Clean Supply Air (CDA)
PFA030 pumps require the use of Class 2 air for particles and moisture per ISO 8573-1. Use a 10-micron filter; maintain -40°C dew point. A point-of-use filter is recommended during the first six months of operation in new fabs/systems due to high risks of debris that can damage pumps and void the warranty. -
Flammable Solvents
PFA030 pumps are not constructed from conductive materials. A system that pumps flammable solvents should be properly grounded to avoid ignition by static charge. A River’s Edge test of isolative pumps with flammable liquids indicated that liquids must be grounded and other procedures should be followed. Copy of test available. -
Pumping Liquids Near Boiling Point
Minimizing suction lift reduces pulsation and the potential for boiling or outgassing of liquid in the inlet of the pump. Although reciprocating pumps can pull a suction lift, pump performance and life increase when the suction lift is minimized or eliminated. -
Abrasive Slurry
Pumping abrasive slurry may accelerate the wear of components. PFA030 pumps are warranted when used with slurry. However, normal wear is not covered by warranty. -
Environmental Temperature
PFA030 pumps are rated for 0°C (32°F) – 50°C (122°F) environmental temperatures. Do not freeze fluid in the pump. Operation below 0°C may accelerate wear. Normal wear is not covered by warranty.
D10 amplifier must be calibrated before attaching fibre optic probes to the pump.
Installation Instructions
Push-Forward Dismount Configuration Setup
Replace step 4 with steps 3.1-3.3 to re-configure the base plate to push-
forward dismount.
Install with Rigid Base Plate
Requires push-forward dismount configuration (steps 3.1-3.3).
Liquid Inlet/Outlet
Liquid ports are not NPT nor any other standard. Use of connectors other than
those supplied by White Knight will damage the pump.
Control & Monitoring
Programmable Control
White Knight CPT-1 controllers monitor and adjust run mode, flow rate, leak
detection and other pump operations.
D10 Amplifier Electrical Hookups & Dimensions
White Knight recommends Expert™ D10 amplifier for use with fibre optic stroke
and leak detection assemblies.
Standard Models and Main Unit
Sub-Units
Shift Logic for Fiber-optic Pumps
Fiber Optic Stroke Detection Installation
For standard end stroke, follow steps for both sides of the pump. For single-
probe dual-detect, follow the steps for only the left side.
- Insert fiber optic probes fully into heads. Push in ferrule and gripper; hand-tighten nut.
- Open the top and slide the front face of the D10 up. Press the fibre optic ends into the holes on its front. Slide the face down to lock cables in place.
Calibrating D10 Amplifier for Stroke Detection
When calibrating the D10 Amplifier for stroke detection, the pump should be in
the same operating conditions it will be in during normal operation (i.e.
supply air pressure, back pressure, etc.). The Fiber Optic must be installed
as per the instructions in section 3.1.
Upon completion of a successful learning cycle, the D10 Amplifier will continuously learn and self-teach to maintain the same cycle rate count readings.
Conductivity Leak Detection Installation
Leaks are identified if conductive fluid contacts a sensor. The sensor
provides a Sink (NPN) or Source (PNP) signal, depending on the wire setup. See
the wiring diagrams below. Conductive leak detection does not qualify for use
in explosion-proof environments. Conductive fluid is required. See below for
the elbow-out configuration.
- Remove the leak adapter from the assembly.
- Replace NPT plug in “L” port with probe. Hand Tighten. Attach the cable to the signal translator (e.g. PLC).
Fiber Optic Leak Detection Installation
- D10 amplifier must be calibrated before attaching fibre optic probes to the pump.
- Fibre optic sensors can melt if used at >130°C (266°F), causing leak detection failure.
See below for the elbow-out configuration.
- Remove the leak adapter and leak detect probe from the fibre optic assembly.
- For straight-out configuration replace the NPT plug-in “L” port with the probe. Hand-tighten.
- Insert the fibre optic cable until it contacts the bottom of the probe.
- Lower the ferrule and gripper until snug against the probe. Hand tighten female gripper nut.
- Open the top and slide the front face of the D10 up. Press the fiber optic ends into the holes on its front. Slide the face down to lock cables in place.
For elbow out configuration:
Calibrating D10 Amplifier for Leak Detection
Step 1: Power On D10 Amplifier & Set “Dark Operate” Mode:
Step 2: Access “Single-Point Dark Set” Mode
Step 3: Set Sensing Condition
- Set the condition to “leak detection” sensing while the probe tip is submerged in liquid.
- Then, remove the leak probe from the liquid and reinsert it into the “L” port.
- The amplifier will now signal when moisture is detected on the probe tip.
Ordering Instructions
Options 1-3 are required. Leave Additional Options blank if not desired. Only add Outlet if different than Inlet.
Fiber optic cables are ordered separately. Fibre optics are required for operation. Standard configuration includes dual probes WITHOUT fibres. See stroke detection options to order fibre optic cables or single probe options.
Timer mode operation requires end-of-stroke detection. The use of timer mode without stroke detection voids the warranty. Operating the pump without the included quick exhaust valves (QEVs) voids the pump warranty. Customers may use their own QEVs with the optional NPT adapter.
Revision
Contact support for revision level or copy exact code activation details.
Configured part numbers are not Copy Exact Part Numbers.
support@wkfluidhandling.com.
Pump Service
Pumps fully rebuilt by White Knight, certified rebuilders, or technicians certified by White Knight receive full warranty renewal. Details below.
- White Knight Rebuilds
- Request factory rebuilds by web form at: https://wkfluidhandling.com/support/rma/. An RMA# will be provided after processing.
- Customers must follow decontamination instructions in Section 4.4 when returning a pump to White Knight.
- Certified Rebuilders
White Knight’s global network of certified rebuilders expedite rebuild turn- around time and minimize shipping costs. Find certified rebuilders at: https://wkfluidhandling.com/rebuilders/.
Rebuild Pump as a Certified Technician
White Knight offers pieces of training to certify technicians to rebuild
pumps. Technicians who pass the training are issued a two-year certification.
During the two years, parts in pumps rebuilt by the technician receive a full
warranty. See https://wkfluidhandling.com/virtual-rebuilds/.
Rebuild Kits & Parts
Rebuild kit for PFA030 is RBPFA030-1. The rebuild kit for PFASD030 is
RBPFASD030-1 (labour not included). To request rebuilds by White Knight, use
RBPFA030-5 or RBPFASD030-5, respectively (labour included).
- Pump rebuilds require tool kit: 12200-XX-0028 (Legacy# PFA030-170)
- Dry-run (SD) pumps use different shaft and shaft seals. Contact White Knight for details.
RBPFA030-1
ITEM NO. | PART NUMBER | DESCRIPTION | QTY. |
---|---|---|---|
1 | 3130-MP-0025 | BELLOWS, A & H, 30L | 2 |
2 | 3200-VI-0001 | DIAPHRAGM, .782 | 2 |
3 | 4100-MP-0004 | CHECK BALL 1/2″ | 4 |
4 | 4135-MP-0006 | CHECK SEAT BOTTOM HI-FLOW 25L & 30L | 2 |
5 | 4142-MP-0004 | CHECK CAGE TOP HI-FLOW 25L & 30L | 2 |
6 | 5143-MP-0001 | SEAL, SHAFT, 30L | 2 |
7 | 5144-PF-0024 | SHAFT, SOLID, PFA, 30L | 1 |
8 | 6140-FP-0002 | BAFFLE, .800″ | 4 |
9 | 6150-UH-0001 | SEAT, QEV EXHAUST, 30L & 60L | 2 |
10 | 8140-TE-0004 | STEM, SD TARGET, 30L | 2 |
11 | 8150-BP-0001 | EXTENSION, TARGET, UNIVERSAL | 2 |
12 | 8150-TE-0005 | EXTENSION, TARGET, .145 | 2 |
13 | 8160-BP-0005 | BLANK, TARGET, .145 | 2 |
Return Pump for Service
Follow decontamination instructions when returning a pump for service.
DO NOT REMOVE THE PAGE FROM THE MANUAL.
Copy the page from the manual or download it at
https://wkfluidhandling.com/support/rma/.
Decontamination Instructions
PRINT COMPLETED DECONTAMINATION CERTIFICATION. IT MUST BE INCLUDED IN YOUR RMA
SHIPMENT.
White Knight products are designed for use with caustic and otherwise dangerous liquids. Handle every product as if it contains dangerous chemicals whether or not it actually does.
- Only those with adequate safety training should attempt to handle used pumps.
- Wear adequate safety gear appropriate for chemicals that have been in the pump.
- Review relevant Material Safety Data Sheets (MSDS) before handling the pump.
- Review emergency numbers for use in the event of an accident.
- Prepare Ph papers, showers, antidotes, clean-up equipment, neutralizers, and other safety devices used to detect, neutralize or minimize the effects of chemicals described in appropriate MSDS documents.
Rinse with DI Water
Circulate DI water through the pump for twenty minutes before disassembly
and/or double bagging for shipment. If the pump is nonfunctional, force DI
water from the inlet through an outlet for 40 minutes before shipment
preparations.
Remove Pump from Station:
- Disconnect liquid tubing connectors from the front of the pump (opposite shuttle valve).
- Plug NPT fittings with PTFE plug, Flare fittings with flare nose cover and cap, or other plug or cap as recommended by the connector supplier.
- Disconnect the air supply tubing from the face of the shuttle valve.
- Loosen the mounting screw from a base plate. (Note: do not remove the screw from the base plate).
- Remove the base plate using proper tool for the fastening devices (e.g. Allen wrench or screw driver). Note: The base plate may stay if needed for a replacement pump to be used.
- Return all removed parts to the pump.
Return Pump to White Knight:
- Rinse the pump with DI water as described above after removing it from its station.
- Drain the remaining DI water from the pump inlet and outlet liquid tubing connectors.
- Plug liquid outlets as described in the Remove Pump from Station section above.
- Dry the pump, double bag it, and seal it in thick polyethylene bags.
- Return the pump to its original packaging.
- Include MSDS for the chemical that the pump was handling in the box with the pump.
- Obtain the RMA number from White Knight and write it on the outside of the box.
- Ship to White Knight following all rules, regulations and laws regarding the shipment of dangerous materials. Ship freight pre-paid. No collect shipments will be accepted. Unauthorized use of White Knight shipping accounts will result in the addition of freight to the bill in addition to a service charge.
Include All Pump Components:
Pumps returned to White Knight for evaluation, service or repair must be
complete with all components, including but not limited to the base plate,
mount screws, tubing connectors, tubing connector caps, flare noses, shuttle
valves, mufflers, and tubing. Missing parts will be added to the pump and
charged to the customer.
DO NOT REMOVE PAGE FROM THE MANUAL.
Copy the page from the manual or download it at
https://wkfluidhandling.com/support/rma/.
Decontamination Certification
COMPLETE AND PRINT THIS FORM. IT MUST BE INCLUDED IN YOUR RMA SHIPMENT.
I, the undersigned employee, certify that all decontamination and safety procedures described in the Decontamination Instructions section have been followed for the return of the product below.
RMA#:
(We cannot process returns without an RMA number.)
Serial#:
(We cannot process returns without a product serial number.)
Metal Exposure:
(Check all that apply. Write in other metals if necessary.)
Chemical Exposure:
(Check all that apply. Write in other chemicals if necessary.)
Shipping Information:
Please indicate the metal processes to which the product has been exposed by
clearly and conspicuously labelling the outside of the return package with the
metal.
Products exposed to Metal Processes must be sent to the following
address:
White Knight Fluid Handling 187 East 670 South, Suite B Kamas, UT 84036
- Print Name:
- Signature:
Products NOT exposed to Metal Processes must be sent to the following
address:
White Knight Fluid Handling 187 East 670 South, Suite C Kamas, UT 84036
Warranty
White Knight follows strict manufacturing, assembly and testing procedures to
ensure consistency and reliability. White Knight warrants that PFA030 pumps
and components are free from defects in materials and workmanship for two
years from our shipment date or your installation date if provided within 90
days of shipment from our facility.
Failures due to normal wear, misuse, abuse or unauthorized disassembly nullify
this warranty.
White Knight does not guarantee the suitability of products for specific applications. White Knight is not liable for any damage or expense resulting from the use or misuse of its products in any application. Responsibility is limited solely to the repair or replacement of defective products or components. Prior written, faxed or emailed approval must be obtained from White Knight before returning any product or component for warranty consideration. All determinations regarding the cause of failure are made by White Knight, and all decisions regarding warranty fulfilment or nullification are made by White Knight.
THE FOREGOING WARRANTY IS EXCLUSIVE AND INSTEAD OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, INCLUDING ANY GUARANTEE OF SUITABILITY FOR ANY PURPOSE.
NO VARIATIONS
THIS WARRANTY SHALL BE HONORED NOR CONSIDERED LEGALLY BINDING, EXCEPT WRITTEN
AGREEMENTS SIGNED BY THE CEO OF WHITE KNIGHT FLUID HANDLING.
Accessories
See ordering instructions or contact us for details.
Stroke Detection
- Fiber Optic stroke detection with or without a sensor
- Solid-state pressure switch
- Solid state dual pressure switch
Leak Detection
- Fiber Optic leak detection with or without a sensor
- Conductivity leak detection
CPT-1
- Control/monitor run mode and flow rate.
Catcher™ Pre-Filters
- In-line and pump-mounted options
- Large through holes to avoid loading
- The filter may be removed without removing the Catcher™ from the pump or the line.
- Pumps damaged by passing solids that use a Catcher™ are repaired as in warranty.
Filter Housing
- 100% non-metallic
- Allows for filter changing without disconnecting the inlet/outlet lines
- Rated for temperatures up to 210°C
- Install with industry-standard connections
- Designed to allow for thermal cycling
- Upright and inverted installation options
Quick Exhaust Valves
- Allows for immediate escape of exhaust air reducing pulsation and exposure of solenoid valve to corrosive fumes
- In-line and pump-mounted options
- UHMW-PE design
- Comes standard with a one-year warranty
Pulse Dampeners
- Uses same CDA as supplied to pump
- In-line and pump-mounted options
- Sizes available for all PFA Series pumps
- Self-adjusting, Auto-Level Valve is regulated by liquid line pressure
DECLARATION OF CONFORMITY
Copyright © 2023 White Knight Fluid Handling | A Graco company
P: 435.783.6040 |
support@wkfluidhandling.com |
https://wkfluidhandling.com.
White Knight Support
- 187 E. 670 S. Kamas, UT 84036
- Phone: 435.783.6040
- Toll Free: 888.796.2476
- Fax: 435.783.6128
- support@wkfluidhandling.com
- https://wkfluidhandling.com/support/.