nVent CADDY CSBQG0250EG Grip Lateral Sway Brace 21-2 Pipe Owner’s Manual
- June 16, 2024
- nVent Caddy
Table of Contents
nVent CADDY CSBQG0250EG Grip Lateral Sway Brace 21-2 Pipe
Product Information
Specifications
-
Catalog Number : CSBQG0250EG
-
Service Pipe Schedule : Lightwall 10 40
-
Wall Thickness : 0.188″
-
Lateral Horizontal Capacity per Installation Angle from
Vertical :- 1,410 lb
- 2,000 lb
- 2,450 lb
- 1,190 lb
- 1,680 lb
- 2,060 lb
- 870 lb
- 1,230 lb
- 1,510 lb
- 970 lb
- 1,370 lb
- 1,680 lb
- 790 lb
- 1,110 lb
- 1,360 lb
- 2,740 lb
- 2,300 lb
- 1,690 lb
- 1,870 lb
- 1,520 lb
-
UL Loads:
-
Part Number: CSBQG0250 – Lateral Sch 10/Sch 40 Service Pipe:
1500 lb -
Part Number: CSBQG0300 – Lateral Sch 10/Sch 40 Service Pipe:
1300 lb -
Part Number: CSBQG0400 – Lateral Sch 10/Sch 40 Service Pipe:
1500 lb -
Part Number: CSBQG0500 – Lateral Sch 10/Sch 40 Service Pipe:
N/A -
Part Number: CSBQG0600 – Lateral Sch 10/Sch 40 Service Pipe:
1400 lb -
Part Number: CSBQG0800 – Lateral Sch 10/Sch 40 Service Pipe:
1400 lb -
Bull Moose Eddy Flow Service Pipe: 1500 lb
-
Wheatland Mega-Flow Service Pipe: 1500 lb
-
Youngstown Fire-Flo Service Pipe: 1500 lb
-
Features
The Quick Grip Lateral Brace, part of the nVent CADDY line of fire sprinkler bracing systems from nVent, is designed to helpsimplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design forquick attachment of brace pipe to service pipe saving time and money.
Certifications
None mentioned in the user manual.
Product Attributes
- FM Loads Part Numbers: CSBQG0250EG, CSBQG0300EG, CSBQG0400EG,
CSBQG0600EG, CSBQG0800EG
Diagrams
No diagrams provided in the user manual.
Warnings
nVent products should only be installed and used as indicated in nVent’s product instruction sheets and training materials. Improper installation, misuse, misapplication, or failure to follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury, and death, and may void the warranty.
Contact Information
- Europe Netherlands: +31 800-0200135
- France : +33 800 901 793
- Germany : 800 1890272
- Other Countries : +31 13 5835404
- APAC Shanghai : + 86 21 2412 1618/19
- Sydney : +61 2 9751 8500
Brands
Our powerful portfolio of brands includes nVent, CADDY, ERICO, HOFFMAN, RAYCHEM, SCHROFF, and TRACER.
Disclaimer
nVent reserves the right to change specifications without notice.
Product Usage Instructions
Step 1: Preparation
Prior to installation, ensure that you have the necessary tools and equipment:
- Quick Grip Lateral Sway Brace
- Service Pipe
- Brace Pipe
- Fasteners (not included)
- Installation Manual (included)
Step 2: Positioning
Determine the appropriate location for the Quick Grip Lateral Sway Brace. It should be placed in a position that provides optimal support to the service pipe.
Step 3: Attachment
Attach the Quick Grip Lateral Sway Brace to the service pipe using the innovative design for quick attachment. Follow the instructions provided in the Installation Manual for proper attachment.
Step 4: Secure
Secure the brace pipe to the Quick Grip Lateral Sway Brace using suitable fasteners. Ensure that the brace pipe is securely fastened to provide maximum stability and support.
Step 5: Testing
After installation, perform a thorough test to ensure that the Quick Grip Lateral Sway Brace is properly attached and providing the necessary support to the service pipe. If any issues are detected, refer to the Troubleshooting section in the Installation Manual or contact nVent customer service for assistance.
Step 6: Maintenance
Regularly inspect the Quick Grip Lateral Sway Brace and all associated components for any signs of damage or wear. If any issues are identified, replace or repair the affected parts as necessary to maintain the integrity and functionality of the brace system.
Step 7: Compliance
Ensure that all installation, usage, and maintenance procedures are in compliance with local building codes and regulations. Failure to comply with these requirements may result in unsafe conditions or non-compliance with legal standards.
Frequently Asked Questions
Q: Are fasteners included with the Quick Grip Lateral Sway Brace?
A : No, fasteners are not included with the Quick Grip Lateral Sway Brace. You will need to provide your own suitable fasteners for attaching the brace pipe to the sway brace.
Q: Can the Quick Grip Lateral Sway Brace be used for both seismic and non- seismic applications?
A : Yes, the Quick Grip Lateral Sway Brace is designed to provide support to the service pipe in both seismic and non-seismic events. However, it is important to follow the installation instructions and guidelines provided by nVent to ensure proper usage and performance.
Q: Can I install the Quick Grip Lateral Sway Brace myself, or do I need professional assistance?
A : The installation of the Quick Grip Lateral Sway Brace can be done by a competent individual with knowledge of bracing systems. However, if you are unsure or inexperienced, it is recommended tseek professional assistance to ensure proper installation and compliance with building codes and regulations
CATALOG NUMBER
CSBQG0250EG
The Quick Grip Lateral Brace, part of the nVent CADDY line of fire sprinkler bracing systems from nVent, is designed to help simplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design for quick attachment of brace pipe to service pipe saving time and money.
CERTIFICATIONS
FEATURES
- Easy two-step installation eliminates extra trips between structure and service pipe
- Works with 1″ and 1 1/4″ (25 mm and 32 mm) brace pipes to reduce inventory
- Yellow tips provide a visual indicator that the bolts have been properly torqued
- Easy installation with an impact wrench from the bottom side of the clamp
- Meets NFPA®-13 requirements for seismic sway bracing
- Meets CEN/TS 17551:2021 requirements for Seismic Sway Bracing
PRODUCT ATTRIBUTES
Material : Steel
Finish : Electrogalvanized
Pipe Size : 2 1/2″
Height : 5 7/16″ – 5 7/8″
Width : 6 3/4″
FM Loads
Part Number
|
Service Pipe Schedule
| Lateral
Horizontal Capacity per Installation Angle from Vertical
30°- 44°| 45°- 59°| 60°- 74°| 75°- 90°
CSBQG0250EG
| Lightwall| 1,410 lb| 2,000 lb| 2,450 lb| 2,740 lb
10| 1,410 lb| 2,000 lb| 2,450 lb| 2,740 lb
40| 1,410 lb| 2,000 lb| 2,450 lb| 2,740 lb
CSBQG0300EG
| Lightwall| 1,190 lb| 1,680 lb| 2,060 lb| 2,300 lb
10| 1,190 lb| 1,680 lb| 2,060 lb| 2,300 lb
40| 1,190 lb| 1,680 lb| 2,060 lb| 2,300 lb
CSBQG0400EG
| Lightwall| 1,190 lb| 1,680 lb| 2,060 lb| 2,300 lb
10| 1,190 lb| 1,680 lb| 2,060 lb| 2,300 lb
40| 1,190 lb| 1,680 lb| 2,060 lb| 2,300 lb
CSBQG0600EG
| Lightwall| 870 lb| 1,230 lb| 1,510 lb| 1,690 lb
10| 870 lb| 1,230 lb| 1,510 lb| 1,690 lb
40| 970 lb| 1,370 lb| 1,680 lb| 1,870 lb
CSBQG0800EG
| 0.188″ (Wall Thickness)| 790 lb| 1,110 lb| 1,360 lb| 1,520 lb
40| 790 lb| 1,110 lb| 1,360 lb| 1,520 lb
UL Loads
Part Number
| Lateral
Sch 10/Sch 40 Service Pipe
|
Bull Moose Eddy Flow Service Pipe
|
Wheatland Mega-Flow Service Pipe
|
Youngstown Fire-Flo Service Pipe
CSBQG0250| 1500 lb| 1500 lb| 1500 lb| 1500 lb
CSBQG0300| 1300 lb| 1300 lb| 1300 lb| 1300 lb
CSBQG0400| 1500 lb| 1500 lb| 1500 lb| 1500 lb
CSBQG0500| N/A| N/A| N/A| N/A
CSBQG0600| 1400 lb| N/A| 1400 lb| N/A
CSBQG0800| 1400 lb| N/A| N/A| N/A
DIAGRAMS
North America
- +1.800.753.9221
- Option 1 – Customer Care
- Option 2 – Technical Support
Europe
- Netherlands : +31 800-0200135
- France : +33 800 901 793
Europe
- Germany : 800 1890272
- Other Countries : +31 13 5835404
APAC
- Shanghai : + 86 21 2412 1618/19
- Sydney : +61 2 9751 8500
Our powerful portfolio of brands: nVent.com CADDY ERICO HOFFMAN RAYCHEM SCHROFF
© 2023 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>