Features
- Wide input range 100~305VAC(class I)
- Full power output at 75~100% constant power mode operation
- Metal case with IP67, suitable for outdoor application
- Surge protection with 6KV/4KV
- 3 in 1 dimming (Dim-to-off and Isolation design)
- Protection Functions: OLP/SCP/OVP/OTP
- Compliance to EN60335-1 household application
- Lifetime>50,000 hours and 5 years warranty
Applications
- Bay lighting
- Stage lighting
- Floodlight lighting
- Horticulture lighting
- Stadium lighting
- LED strip lighting (ABV type)
- Agricultural lighting (ABV type)
- DMX power supply
- Type “HL” for use in class I, Division 2
- Household devices
- Retail and refrigerated display
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
XLG-320 series is a 315W LED AC/DC driver featuring with constant power mode. XLG-320 operates from 120-305VAC and offers models with different rated current ranging between 1050mA and 7420mA. Thanks to the high efficiency up to 94.5% with the fanless design, the entire series is able to operate for 40°C~+85°C case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG-320 series comply with the latest version of IEC61347/GB19510.1 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations and isolation to ensure the safety of both user and luminaire system during installation.
Model Encoding
Type | lP Level | Function | Note |
---|---|---|---|
Blank | lP67 | lo and Vo fixed.(For harsh environment) | By request |
A | lP67 | Output constant power adjustable via built-in lo potentiometer | ln |
Stock
AB| lP67| Output constant power adjustable via built-in lo potentiometer +3 in
1 dimming function (0~10Vdc, 10V PWM signal and resistance)| ln Stock
ABV(48V only)| lP67| Vo adjustable via built-in potentiometer +3 in 1 dimming
function (Flicker free C.V. Dimming)| ln Stock
Note:
- V model is constant voltage operation without the AB type
- 48-V/48-BV types are available by modification version, please consult MEANWELL for detail.
SPECIFICATION
MODEL | XLG-320-L- | XLG-320-M- | XLG-320-H- | XLG-320-V- |
---|---|---|---|---|
OUTPUT | RATED CURRENT (Default) | 1400mA | 2800mA | 5600mA |
RATED POWER Note.10 | 315W | 310.8W | 312W | 24V/312W, 12V/216W |
CONSTANT CURRENT REGION | 150~300V | 74 ~ 148V | 30 ~ 56V | NC |
OUTPUT VOLTAGE ADJ. RANGE | NC | NC | NC | 24V or 12V |
FULL POWER CURRENT RANGE | 1050~1400mA | 2100~2800mA | 5570~7420mA |
13~18A(24V/13A,12V/18A)
OPEN CIRCUIT VOLTAGE (max.)| 340V| 180V| 60V| NC
CURRENT ADJ. RANGE| 500~1400mA| 1050~2800mA| 2800~7420mA| NC
CURRENT RIPPLE| 5.0% max. @rated current| 5.0 max. @rated current| 5.0% max.
@rated current| NC
CURRENT TOLERANCE| ±5%| ±5%| ±5%| NC
RIPPLE & NOISE(max.)| NC| NC| NC| 240mV p-p
VOLTAGE TOLERANCE| NC| NC| NC| ±3%
LINE REGULATION| NC| NC| NC| ±0.5%
LOAD REGULATION| NC| NC| NC| ±2%
SET UP TIME Note.9| 500ms/230VAC, 1200ms/115VAC
RISE TIME,HOLD UP TIME (Typ.)| 160ms,10ms/230VAC/115VAC(only for V-type)
INPUT| VOLTAGE RANGE Note.2| 100 ~ 305VAC 142VDC ~ 431VDC(Please
refer to “STATIC CHARACTERISTIC” ang “ DRIVING METHODS OF LED MODULE”section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.98 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 / 277VAC at
full load(Please refer to “Power Factor Characteristic” section)
TOTAL HARMONIC DISTORTION| THD< 10% @ load≧50% at 115VAC/230VAC,
THD15%@Load75% at 277VAC;Please refer to “TOTAL HARMONIC DISTORTION (THD)”
section
EFFICIENCY (Typ.)| 94.5%| 93.5%| 92.5%| 93%
AC CURRENT (Typ.)| 3A / 120VAC 1.6A / 230VAC 1.3A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 45A(twidth=1200μs measured at 50% Ipeak) at
230VAC; Per NEMA 410
MAX. NO. of PSUs on 16ACIRCUIT BREAKER| 2 unit(circuit breaker of type B) / 4
units(circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
STANDBY POWER CONSUMPTION Note.5| Standby power consumption <0.5W for
AB-Type(Dimming OFF)
PROTECTION| SHORT CIRCUIT| Hiccup mode or Constant current limiting, recovers
automatically after fault condition is removed
OVER VOLTAGE| 350 ~ 380V| 190 ~ 220V| 63 ~ 78V| 27 ~ 34V
Shut down output voltage, re-power on to recovery
OVER TEMPERATURE Note.11| L/M/H-Type: Tcase>85℃±5℃,derate power
automatically V-Type: Shut down output voltage, re-power on to recover
OVER LOAD Note.10| 108~135%(only for V-type)
Hiccup mode or Constant current limiting, recovers automatically after fault
condition is removed
ENVIRONMENT| WORKING TEMP.| Tcase=-40 ~ +85℃(Please refer to “OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+85℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z
axes
SAFETY & EMC| SAFETY STANDARDS| UL8750(type”HL”), CSA C22.2 No. 250.13-12;
ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384,
EN/EN60335-1 compliant to EN 60335-2-89 Annex BB, EN 60335-2-24 Annex
CC;GB19510.1, GB19510.14;EAC TP TC 004; IP67;IS15885(Part2/Sec13)(except for
blank type), KC61347-1,KC61347-2-13 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55015(CISPR15) ,GB/T17743| —–
Radiated| BS EN/EN55015(CISPR15),GB/T17743| —–
Harmonic Current| BS EN/EN61000-3-2 , GB/T17625.1| Class C @load≥50%
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61547
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| 4KV/Line-Line 6KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,>95% interruptions 250 periods
OTHERS| MTBF| 1476.4K hrs min. Telcordia SR-332(Bellcore) ; 168.1 K hrs min.
MIL-HDBK-217F (25℃)
DIMENSION| 2467739.5mm (LWH)
PACKING| 1.45Kg;9pcs/14Kg/0.76CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- De-rating may be needed under low input voltages. Please refer to “STATlC CHARACTERlSTlC” sections for details.
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- This series meets the typical life expectancy >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is 75℃ or less.
- To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
- Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and lP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- Products sourced from the Americas regions may not have the ENEC/CCC/KC logo. Please contact your MEAN WELL sales for more information.
- The output voltage of the V Type default is 24V, for 12V output, please adjust SVR by clockwise direction to the end, otherwise the OLP point is not within the specification range.
- When the secondary OTP fails, there is also a primary OTP, which is protected by Shut down output voltage, re-power on to recovery for the H/M/L-type.
- When the current adjustment is more than 110% of the rated current, it will be enter the Protection state.
- V,H type:RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. M,L type:RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
- lt may has an over-shoot status at output current when AC On/Off operate with lower Vf and lower loading conditions.
- lf you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Please refer to “DRlVlNG METHODS OF LED MODULE”.
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
XLG-320-L
XLG-320-M
XLG-320-H
**XLG-320-V
**
V type output voltage adjustable via biult-in potentiometer
DIMMING OPERATION
3 in 1 dimming function (for AB-Type)
- Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
- Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
- Dimming source current from power supply: 100μA (typ.)
Applying additive 0 ~ 10VDC
“DO NOT connect “DIM- to Vo-”
Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
“DO NOT connect “DIM- to Vo-”
Applying additive resistance:
“DO NOT connect “DIM- to Vo-”
Dimming input: Additive voltage
Duty cycle of additive 10V PWM signal dimming input
(N=driver quantity fosrynchronized di mming operation ) Dimming input:
Additive resistance
Note :
- Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.
- The output current could drop down to 0% when dimming input is about 0Ωor 0Vdc, or 10V PWM signal with 0% duty cycle.
- When PWM frequency >2K HZ ,the lighting will be triggered at 10~15% PWM duty .
DIMMING OPERATION
3 in 1 dimming function (for ABV-Type)
- Output constant voltage can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
- Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
- Dimming source current from power supply: 100μA (typ.)
Applying additive 0 ~ 10VDC
“DO NOT connect “DIM- to Vo-”
Applying additive 10V PWM signal (frequency range 200Hz ~ 3KHz):
“DO NOT connect “DIM- to Vo-”
Applying additive resistance:
“DO NOT connect “DIM- to Vo-”
Dimming input: Additive voltage
Duty cycle of additive 10V PWM signal dimming input
(N=driver quantity for synchronized dimming operatio)n Dimming input:
Additive resistance
Note :
- Min. dimming level is about 50% of output voltage and the output voltage is not defined when Vout<50%
- The output voltage could drop down to 0V when dimming input is about 0k or 0Vdc, or 10V PWM signal with 0% duty cycle.
OUTPUT LOAD vs TEMPERATURE
AMBIENT TEMPERATURE,Ta ( ) ℃
Tcase ( ) ℃
STATIC CHARACTERISTIC
INPUT VOLTAGE (V) 60Hz
POWER FACTOR (PF) CHARACTERISTIC
Tcase at 85℃
Constant Current Mode
TOTAL HARMONIC DISTORTION (THD)
XLG-320-L Model, Tcase at 85℃
FFICIENCY vs LOAD
XLG-320 series possess superior working efficiency that up to 94.5% can be reached in field applications
XLG-320-L Model, Tcase at 85℃
CONSTANT VOLTAGE DIMMING OPERATION:
48-ABV type
Note: flicker free design for agricultural lighting flicker free design for Indoor LED strip lighting
Dimming Curve
DC Voltage Level
(Not a PWM style output)
LIFE TIME
MECHANICAL SPECIFICATION
V-A-Type
H/L/M-A-Type
AB/ABV-Type
Recommend Mounting Direction
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)