Product Information

Product Name: UHPP HBK-A02W TE Access Control Keypad

User Manual: EN User Manual

Packing List:

Name Quantity Remarks
Access Keypad 1
Connector with cable of 9-27/32 1
User Manual 1
Plastic Anchors 4
Self – Tapping Screw 4

Product Introduction

  • * This RFID card access control unit controls 1 door. It uses ST MCU to ensure stable performance, and low-power circuit makes the service life longer.
    • OMRON power relay with 10A switching capacity provides an excellent switching performance for electric locks.
    • It is widely used in factories, houses, residential quarters, offices, mechanical and electrical control equipment and so on.
  • Specifications
    • Operating Voltage: 12VDC
    • Lock Output Load: Max. 1.5A
    • Card Capacity: 1000
    • Card Type: Standard 125KHz EM
    • PIN Capacity: 500
    • Door Open Time: 0-99 seconds
    • Idle Current: 50mA
    • Operating Humidity: 10%-90%RH
    • Waterproof: No
    • Enclosure Material: ABS Plastic
    • Product Weight: 3.53oz
    • Dimensions: 4-21/64×2-51/64×29/32
    • WiFi Standard: 2412-2462MHz
  • Installation
    • Wall: 2
  • Wiring Diagram – Common Power Supply Diagram
    • POWER: +12V GND
    • EXIT BUTTON: – Fail-secure lock + – Fail-safe lock +
    • BELL: +12V (RED) GND (BLACK) OPEN (YELLOW) PUSH (GREEN) NO (BLUE) COM (WHITE) NC (BROWN) BELL (PINK) BELL (PINK)
  • Wiring Diagram – Special Power Supply Diagram
    • +12V: GND
    • PUSH: EXIT BUTTON NO
    • + Fail-secure lock: – COM NC
    • + Fail-safe lock: – BELL +12V (RED) GND (BLACK) OPEN (YELLOW) PUSH (GREEN) NO (BLUE) COM (WHITE) NC (BROWN) BELL (PINK) BELL (PINK)
  • Wiring Harness Connections:
    • +12V: RED
    • GND: BLACK
    • OPEN: YELLOW
    • PUSH: GREEN
    • NO: BLUE
    • COM: WHITE
    • NC: BROWN
    • BELL: PINK

Sound and Light Indication

Operation Status LED Indicator Buzzer
Standby White Blue
PIN only mode Red Green
Another mode Flash yellow Blue
In the programming mode Yellow Flash green 1 time
When a menu is waiting to be selected Flash blue
The menu selected
Unlock the lock A short beep
Enter the PIN A short beep 3 short beeps
Operation successful Flash red 3 times A short beep
Operation failed Press digit key

Operation Guide

  • Purpose
    • The purpose of the operation guide is to provide instructions on how to use the access control keypad.
  • Operation
    • Enter the programming mode: # Admin Code #
    • Return to the previous menu in the programming mode: *
    • Exit from the programming mode: #
  • Basic Operation:
    • Change the admin code:
    • New Admin Code #
    • Repeat New Admin Code #
    • The admin code can be 4-8 digits.
    • Red Card:
    • Read Card 1
    • Read Card 2
    • Read Card N #
  • Add card users:
    • User ID Number # Read Card #
  • Add or change a PIN user:
    • User ID Number # PIN #
    • The user ID number is any 4-digit number from 0001 to 9999. Users can be added continuously by repeating the operation.
    • Delete users: User ID Number #
    • Users can be deleted continuously.
  • Delete all users 0000 #
    • Attention: Delete all PIN users & card users except the public code.
    • Set public code: Public Code # Repeat Public Code #
    • Set open mode: 0000 #
  • FAQ
    • Q: What is the default admin code?
    • A: The default admin code is 123456.

Packing List

UHPPOTE-HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-
FIG-1 \(4\)

Introduction

  • This RFID card access control unit controls 1 door. It uses ST MCU to ensure stable performance, and low-power circuit makes the service life longer.
  • OMRON power relay with 10A switching capacity provides an excellent switching performance for electric locks.
  • It is widely used in factories, houses, residential quarters, offices, mechanical and electrical control equipment and so on.

Features

  • Full programming from the keypad.
  • Supports Card, PIN, Card + PIN, Card or PIN.
  • Can be used as a standalone keypad.
  • Adjustable door open time.
  • Very low power consumption.
  • Lock output current short circuit protection.
  • With bell function, supports external bell.
  • Adopt the switch mode power supply (SMPS) solution.
  • Built-in buzzer.
  • Red, blue, white, yellow and green LED indicators display the working status.

Specifications

UHPPOTE-HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-
FIG-1 \(5\)

Installation

  • Remove the back cover from the keypad
  • Drill 4 holes on the wall for the self-tapping screws and 1 hole for the cable
  • Put the supplied plastic anchors into the 4 holes
  • Fix the back cover firmly on the wall with 4 self-tapping screws
  • Thread the cable through the cable hole
  • Attach the keypad to the back cover.

WallUHPPOTE-HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-
Reader-FIG-1 \(1\)

Wiring Diagram

Common Power Supply Diagram

UHPPOTE-HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-
FIG-1 \(2\)

Special Power Supply Diagram

UHPPOTE-HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-
FIG-1 \(3\)

Wiring harness Connections

  • +12V: RED
  • GND: BLACK
  • OPEN: YELLOW
  • PUSH: GREEN
  • NO: BLUE
  • COM: WHITE
  • NC: BROWN
  • BELL: PINK

Sound and Light Indication

UHPPOTE-HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-
FIG-1 \(6\)

Operation Guide

UHPPOTE-HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-
FIG-1 \(7\)UHPPOTE-
HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-FIG-1
\(8\) UHPPOTE-HBK-
A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-FIG-1
\(9\)UHPPOTE-HBK-
A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-FIG-1
\(10\) UHPPOTE-
HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-FIG-1
\(11\)

Troubleshooting

  • Q: Why can’t the door be unlocked after I swipe an added card?
    • A: Please check whether you have set the door open mode to entry by PIN only.
  • Q: Why is there no sound when I press the numeric keypad?
    • A: Please check whether you have disabled the buzzer. If yes, please enable the buzzer according to the operation guide.
  • Q: Why there are 3 short beeps when I try to add a card user in the programming mode?
    • A: This card has been added already.
  • Q: Why isn’t the door unlocked when the LED indicator keeps flashing green after I swipe the added card?
    • A: You have set the door open mode to entry by Card and PIN, please unlock the door by using your card and PIN together.
  • Q: How to replace the card that corresponds to a certain user ID number?
    • A: Please delete this user ID number first and then re-add it.

Tuya Smar t APP Operation Guide

  1. Download Tuya Smar t APP
    • Search ‘Tuya Smart’ in the Apple Store for the iOS version or Google Play for the Android version.
  2. Registration and Login
    • Tap ‘Register’ on the top-right corner, then input a valid mobile number or email address and tap ‘Get Verification Code’.
    • Enter the verification code set the password, and tap ‘Done’.
  3. WiFi Matching
    • Step 1. Press #admin code#69# on HBK-A02W to start wifi matching.
    • Step 2. Tap ‘Add Device’ on the home page of the Tuya app followed by tapping ‘Add’ to enter Wi-Fi information.
    • Step 3. Choose Wi-Fi and enter a password.
    • The Wi-Fi must be the same as the phone connecting, otherwise it will cause offline problems.
    • The Tuya Smart only supports 2.4GHz Wi-Fi communication protocol and can’t support 5GHz.
    • Step 4. The Tuya Smart app will search for nearby devices and connect to the HBK-A02W.
    • Step 5. Name the added device.UHPPOTE-HBK-A02W-Wi-Fi-Door-Access-Control-Keypad-Proximity-Card-Reader-FIG-1 \(18\)

FCC

FCC Warning

FCC ID: 2A4H6HBK-A01
This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used following the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with a minimum distance between 20cm of the radiator and your body: Use only the supplied antenna.  2023 HOBK Electronic Technology Co., Ltd All rights reserved  >75% recycled paper.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals