UHPPOTE HBK-R01 Access Control Outswinging User Manual
- June 16, 2024
- UHPPOTE
Table of Contents
HBK-R01 Access Control Outswinging
HBK-R01 REMOTE CONTROL
Specifications
-
* Receiver
- Operating Voltage: 12VDC
- Output Current: 1A
- Operating Environment: Indoor
- Lock Output Port: 1
- Exit Button Output Port: 1
- Keypad Connection Port: 1
- RF Frequency: 433.92MHz
- Transmitter Support: Max. 40
- RF Channel: 1
- Operating Current: 20mA
- Time Delay: 0/5/10 seconds
- Built-in Buzzer: Yes
- DC Encoding Type: Learning Code
- Operating Method: RF Remote
- Operating Distance: 164 feet without block
- Dimensions: 3-37/64x 2-21/64x 1-9/64 [91x59x29mm]
-
Transmitter
- Operating Current: 10mA
- Enclosure Material: ABS Plastic
- Batteries Type: CR2016 (Built-in)
- Transmitting Frequency: 433.92MHz
- Operating Voltage: 6VDC (Powered by 2pcs CR2016 batteries)
Wiring Diagram
-
Connect Fail-Secure Lock
Access Keypad +12V GND PUSH COM Input Select NO V+ V- Exit Button
Fail-secure Lock
-
Connect Fail-Safe Lock
Access Keypad +12V GND PUSH COM Input Select NC V+ VNO COM NC Exit Button
Fail-safe Lock
Operating Settings
-
Remote Pairing: Tap RF icon followed by press
the button on the transmitter within 20 seconds. -
Unpairing: Tap and hold RF icon for 5 seconds.
Remarks: The operation will clear all paired transmitters, please
operate with caution. -
Lock Type Setting: NO: Fail-Secure Lock, NC:
Fail-Safe Lock. Remarks: Incorrect setting will affect operating of
the lock, please confirm the lock type before setting. -
Buzzer Setting: ON: Enable. OFF: Disable.
-
Operating Mode Select: Momentary: Press button
A for ON, Release button A for OFF. Latched: Press button A for ON,
press button B for OFF. Toggle: Press button A for ON, press button
A again for OFF. Remarks: Latched is only valid when using a
transmitter with 2-buttons. -
Time Delay Setting: Support 0/5/10 seconds
time delay. Remarks: Only available when Momentary selected.
Trouble Shooting
-
Q: Why does not the transmitter’s LED light up when I
press the button on it ?
A: The battery power may be exhausted. Please replace the
battery. -
Q: Why can’t the lock be unlocked after pressing the
transmitter?
A: Please check the issue by the following steps:
a. Check whether the remote control receiver and transmitter are
paired successfully.
b. Check whether there is any metal object around the remote
control receiver as it may shield the signal. -
Q: Why can’t the lock work properly when the wiring is
correct?
A: Please check whether the indicator of the receiver is on and the
mode of lock is selected correctly. (For more details, please refer
to ‘Lock Type Setting’ in this manual.)
Fcc Warning
HBK-R01
REMOTE CONTROL
EN USER MANUAL ES MANUAL DEL USUARIO
EN
Thank you for choosing the HBK-R01 remote control provided by us.
Precaution
For avoidance of damage to the product or injury to the people, please
carefully read this manual before use and keep it for further reference.
! Warnings
· For avoidance of damage to the product, do not expose the product to rain or
damp.
· This product is only for indoor use. · Please use a combination of
transmitter and receiver provided
by us as we can’t guarantee our transmitters or receivers are fully compatible
with other manufacturers products. · The product installation shall be
conducted by a professional electrician as it requires specialized knowledge.
Incorrect operation may damage the product, or make it inoperable. · The
transmitter and receiver have been paired with each other in factory. · Keep
this product away from children under 3 year old to prevent ingestion. ·
Install the receiver in a place out of touch of children, so as to prevent
electric shock. · Please do not put the battery in water, fire or moisture
places for avoidance of explosion. · The battery contains hazardous substance.
Return the waste batteries to the recycling bin to avoid contamination to the
environment.
1
EN
Features
· aSpppelciHeiadolitzomeodethfoeSrretfiheceludascr.cietsys Ccoanmtroel
sryastem and unable to be
· Support connecting external access control keypad. (Remarks: Access control
keypad is excluded.)
· Built-in buzzer makes sound to remind people when the door is locked or
unlocked.
· Built-in diode, real-time protecting electric lock, prolonging the service
life.
HBK-R01 REMOTE CONTROL
Buzzer
Access Keypad Port
Indicator Light
Lock Type
Remote Pairing Exit Button Port Power Port
Buzzer Operating Mode
Time Delay
Lock Port
2
EN
Specifications
Receiver
Operating Voltage: 12VDC
Output Current: 1A
Operating Environment: Indoor Lock Output Port: 1
Exit Button Output Port: 1
Keypad Connection Port: 1
RF Frequency: 433.92MHz Transmitter Support: Max. 40
RF Channel: 1 Operating Current: 20mA
Time Delay: 0/5/10 seconds Built-in Buzzer: Yes DC Encoding Type: Learning Code
Enclosure Material: ABS Plastic Ambient Humidity: 0%RH-95%RH(Non-condensing) Ambient Temperature: -22°F to 140°F
Operating Method: RF Remote
Operating Distance: 164 feet without block Operating Mode: Momentary/Toggle/Latched
Dimensions: 3-37/64″x 2-21/64″x 1-9/64″ [91x59x29mm] Transmitter
Operating Current: 10mA Enclosure Material: ABS Plastic
Batteries Type: CR2016 (Built-in) Transmitting Frequency: 433.92MHz
Operating Voltage: 6VDC (Powered by 2pcs CR2016 batteries)
3
EN
Wiring Diagram
- Connect Fail-Secure Lock
Access Keypad
+12V GND PUSH COM
Input
Select NO
V+ V-
Exit Button
4
Fail-secure Lock
EN
- Connect Fail-Safe Lock
Access Keypad
+12V GND PUSH COM
Input
Select NC
V+ VNO COM NC
Exit Button
5
Fail-safe Lock
EN
Operating Settings 1) Remote Pairing
Tap RF icon followed by press the button on the transmitter within 20 seconds.
2) Unpairing Tap and hold RF icon for 5 seconds. Remarks: The operation will
clear all paired transmitters, please
operate with caution.
NO NC
LOCK TYPE
RF
- Lock Type Setting
NO: Fail-Secure Lock
NC: Fail-Safe Lock
Remarks: Incorrect setting will affect operating of the lock,
please confirm the lock type before setting.
NO NC
LOCK TYPE
RF
6
EN 4) Buzzer Setting
ON: Enable. OFF: Disable.
5) Operating Mode Select Momentary: Press button A for ON, Release button A
for OFF. Latched: Press button A for ON, press button B for OFF. Toggle: Press
button A for ON, press button A again for OFF. Remarks: Latched is only valid
when using a transmitter with 2-buttons.
7
EN 6) Time Delay Setting
Support 0/5/10 seconds time delay. Remarks: Only available when Momentary
selected.
Trouble Shooting 1. Q: Why does not the transmitter’s LED light up when I
press
the button on it ? A: The battery power may be exhausted. Please replace the
battery. 2. Q: Why can’t the lock be unlocked after pressing the transmitter?
A: Please check the issue by the following steps:
a. Check whether the remote control receiver and transmitter are paired
successfully. b. Check whether there is any metal object around the remote
control receiver as it may shield the signal. 3. Q: Why can’t the lock work
properly when the wiring is correct? A: Please check whether the indicator of
the receiver is on and the mode of lock is selected correctly. (For more
details, please refer to ‘Lock Type Setting’ in this manual.)
8
EN
Fcc Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.Any changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment. NOTE: This equipment
has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be deter mined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures: — Reorient or relocate the receiving antenna. — Increase
the separation between the equipment and receiver. — Connect the equipment
into an outlet on a circuit different from that to which the receiver is
connected. — Consult the dealer or an experienced radio/TV technician for
help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment
should be installed and operated with minimum distance between 20cm the
radiator your body: Use only the supplied antenna.
9
ES
Gracias por elegir el mando a distancia HBK-R01 que le proporcionamos.
Precaución
Para evitar daños en el producto o en las personas, lea atentamente este
manual antes de utilizarlo y consérvelo para futuras consultas.
! Advertencias
· Para evitar daños en el producto, no lo exponga a la lluvia o a la humedad.
· Este producto es sólo para uso en interiores. · Por favor, utilice una
combinación de transmisor y receptor
proporcionada por nosotros, ya que no podemos garantizar que nuestro
transmisor o receptor sea totalmente compatible con los productos de otros
fabricantes. · La instalación del producto debe ser realizada por un
electricista profesional, ya que requiere conocimientos especializados. Una
operación incorrecta puede dañar el producto o hacerlo inoperable. · El emisor
y el receptor vienen emparejados de fábrica. · Mantenga este producto fuera
del alcance de los niños menores de 3 años para evitar su ingestión. · Instale
el receptor en un lugar fuera del alcance de los niños, para evitar descargas
eléctricas. · Por favor, no coloque la batería en lugares con agua, fuego o
humedad para evitar una explosión. · La batería contiene sustancias
peligrosas. Devuelva las pilas usadas al contenedor de reciclaje para evitar
la contaminación del medio ambiente.
10
ES
Características
· EasppliecHcaioraslmeizaaedootSrpoeascrcauaemrl pistiosyste. Cmaa
mdeecornatrol de acceso e incapaz de
· Soporta la conexión de un teclado de control de acceso externo. (Nota: se
excluye el teclado de control de acceso).
· El zumbador incorporado emite un sonido para recordar cuando la puerta está
bloqueada o desbloqueada.
· Diodo incorporado, protección en tiempo real de la cerradura eléctrica,
prolongando la vida útil.
HBK-R01 CONTROL REMOTO
Zumbador
Acceso al puerto del teclado
Luz indicadora
Tipo de cerradura
Emparejamiento remoto Puerto del botón de salida Puerto de alimentación
11
Zumbador Modo de funcionamiento
Tiempo de retraso Puerto de la cerradura
ES
Especificaciones
Receptor
Tensión de entrada: 12VDC
Corriente de salida: 1A
Puerto de conexión del teclado: 1 Canal RF: 1
Botón de salida Puerto de salida: 1 Bloqueo del puerto de salida: 1
Soporte para transmisores: Max. 40 Frecuencia RF: 433,92MHz
Corriente de funcionamiento: 20mA Zumbador incorporado: Sí
Entorno de funcionamiento: Interior
Tiempo de retardo: 0/5/10 segundos
Material de la carcasa: Plástico ABS
Tipo de codificación DC: Código de aprendizaje
Humedad ambiente: 0%RH-95%RH (sin condensación)
Temperatura ambiente: -22°F a 140°F
Método de funcionamiento: Transmisor RF
Distancia de funcionamiento: 164 pies sin bloque
Modo de funcionamiento: Momentáneo / Alternado / Bloqueado
Dimensions: 3-37/64″x 2-21/64″x 1-9/64″ [91x59x29mm]
Transmisor
Corriente de funcionamiento: 10mA
Material de la carcasa: Plástico ABS
Tipo de pilas: CR2016 (incorporada)
Frecuencia de transmisión: 433,92MHz
Tensión de funcionamiento: 6VDC (alimentado por 2 pilas CR2016)
12
ES
Diagrama de cableado
- Conexión Cerradura Fail-Secure
Teclado de acceso
+12V GND PUSH COM
Entrada
Seleccione NO
V+ V-
Botón de salida Bloqueo Fail-Secure
13
ES
- Conexión Cerradura Fail-Safe
Teclado de acceso
+12V GND PUSH COM
Entrada
Seleccione NC
V+ VNO COM NC
Botón de salida Bloqueo Fail-Safe
14
ES
Ajustes de funcionamiento
- Emparejamiento remoto Pulse el icono RF y, a continuación, pulse el botón del transmisor antes de que transcurran 20 segundos.
- Desempeñando Mantenga pulsado el icono RF durante 5 segundos. Nota: Esta operación borrará todos los transmisores emparejados, por favor opere con precaución.
NO NC
LOCK TYPE
RF
- Ajuste del tipo de cerradura
NO: Bloqueo Fail-Secure
NC: Bloqueo Fail-Safe
Nota: Un ajuste incorrecto afectará al funcionamiento de la cerradura, por favor confirme el tipo de cerradura antes de
ajustarla.
NO NC
LOCK TYPE
RF
15
ES 4) Ajuste del zumbador
ON: Habilitar OFF: Desactivar
5) Selección del modo de funcionamiento Momentáneo: Pulse el botón A para ON,
suelte el botón A para OFF. Bloqueado: Pulse el botón A para ON, pulse el
botón B para OFF. Alternado: Pulse el botón A para ON, pulse de nuevo el botón
A para OFF. Nota: El bloqueado sólo es válido cuando se utiliza un transmisor
con 2 botones.
16
ES 6) Ajuste del tiempo de retardo
Soporta un retardo de 0/5/10 segundos. Nota: Sólo está disponible cuando se
selecciona Momentáneo.
Solución De Problemas 1. Q: Por qué no se enciende el LED del transmisor
cuando presiono
el botón en él? A: La energía de la batería puede estar agotada. Reemplace la
batería. 2. Q: Por qué no se puede desbloquear la cerradura después de pre-
sionar el transmisor? A: Verifique el problema mediante los siguientes pasos:
a. Compruebe si el receptor y el transmisor del control remoto están
emparejados correctamente. b. Compruebe si hay algún objeto metálico alrededor
del receptor
del control remoto, ya que puede bloquear la señal. 3. Q: Por qué la cerradura
no puede funcionar correctamente cuando
el cableado es correcto? A: Compruebe si el indicador del receptor está
encendido y si el
modo de bloqueo está seleccionado correctamente. (Para obtener más detalles,
consulte ‘Ajuste del tipo de cerradura’ en este manual).
17
ES
Adver tencia FCC
Este dispositivo cumple con la parte 15 de las reglas FCC. La operación está
limitada por dos condiciones: (1) el dispositivo no puede causar interferencia
perjudicial, y (2) el dispositivo debe aceptar cualquier interferencia
recibida, incluyendo cualquier interferencia que pueda causar un
funcionamiento inesper-ado. Cualquier cambio o modificación que no haya sido
expresamente aprobada por la parte responsable de la OCDEpuede dar lugar a la
invalidación de la autoridad del usuario para operar el equipo.
Nota: De conformidad con la parte 15 de las normas FCC, este equipo ha sido
probado para cumplir los límites de los dispositivos digitales de clase B.
Estas restricciones tienen por objeto proporcionar una protección razonable
contra las perturbaciones perjudiciales en las instalaciones residenciales. El
equipo genera, utiliza y irradia energía de radiofrecuencia que puede causar
interferencias perjudiciales en las comunicaciones de radio si no se instala y
utiliza de acuerdo con las instrucciones. Sin embargo, no hay garantía de que
no haya inter-ferencia en una instalación en particular. Si el dispositivo
causa una interferencia perjudicial en la recepción de radio o televisión,
puede determinarse apagando y encendiendo el dispositivo, alentando al usuario
a tratar de corregir la interferencia mediante una o más de las siguientes
medidas: — Reorientar o reubicar la antena receptora. — Aumentar la distancia
entre el dispositivo y el receptor. — Conecte el dispositivo a un enchufe
diferente del circuito conectado al receptor. — Consulte a su distribuidor o
técnico de radio / televisión experimentado para obtener ayuda. Para cumplir
con las directrices de exposición a radiofrecuencia de la FCC, este
dispositivo debe instalarse y funcionar a una distancia mínima del radiador,
es decir, a 20 cm de su cuerpo: utilice sólo las antenas proporcionadas.
18
C 2023 HOBK Electronic Technology Co., Ltd All rights reserved
75% recycled paper
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>