Specifications

  • * Receiver
    • Operating Voltage: 12VDC
    • Output Current: 1A
    • Operating Environment: Indoor
    • Lock Output Port: 1
    • Exit Button Output Port: 1
    • Keypad Connection Port: 1
    • RF Frequency: 433.92MHz
    • Transmitter Support: Max. 40
    • RF Channel: 1
    • Operating Current: 20mA
    • Time Delay: 0/5/10 seconds
    • Built-in Buzzer: Yes
    • DC Encoding Type: Learning Code
    • Operating Method: RF Remote
    • Operating Distance: 164 feet without block
    • Dimensions: 3-37/64x 2-21/64x 1-9/64 [91x59x29mm]
  • Transmitter

    • Operating Current: 10mA
    • Enclosure Material: ABS Plastic
    • Batteries Type: CR2016 (Built-in)
    • Transmitting Frequency: 433.92MHz
    • Operating Voltage: 6VDC (Powered by 2pcs CR2016 batteries)

Wiring Diagram

  1. Connect Fail-Secure Lock

    Access Keypad +12V GND PUSH COM Input Select NO V+ V- Exit Button

    Fail-secure Lock

  2. Connect Fail-Safe Lock

    Access Keypad +12V GND PUSH COM Input Select NC V+ VNO COM NC Exit Button

    Fail-safe Lock

Operating Settings

  1. Remote Pairing: Tap RF icon followed by press
    the button on the transmitter within 20 seconds.

  2. Unpairing: Tap and hold RF icon for 5 seconds.
    Remarks: The operation will clear all paired transmitters, please
    operate with caution.

  3. Lock Type Setting: NO: Fail-Secure Lock, NC:
    Fail-Safe Lock. Remarks: Incorrect setting will affect operating of
    the lock, please confirm the lock type before setting.

  4. Buzzer Setting: ON: Enable. OFF: Disable.

  5. Operating Mode Select: Momentary: Press button
    A for ON, Release button A for OFF. Latched: Press button A for ON,
    press button B for OFF. Toggle: Press button A for ON, press button
    A again for OFF. Remarks: Latched is only valid when using a
    transmitter with 2-buttons.

  6. Time Delay Setting: Support 0/5/10 seconds
    time delay. Remarks: Only available when Momentary selected.

Trouble Shooting

  1. Q: Why does not the transmitter’s LED light up when I
    press the button on it ?

    A: The battery power may be exhausted. Please replace the
    battery.

  2. Q: Why can’t the lock be unlocked after pressing the
    transmitter?

    A: Please check the issue by the following steps:
    a. Check whether the remote control receiver and transmitter are
    paired successfully.
    b. Check whether there is any metal object around the remote
    control receiver as it may shield the signal.

  3. Q: Why can’t the lock work properly when the wiring is
    correct?

    A: Please check whether the indicator of the receiver is on and the
    mode of lock is selected correctly. (For more details, please refer
    to ‘Lock Type Setting’ in this manual.)

Fcc Warning

HBK-R01

REMOTE CONTROL

EN USER MANUAL ES MANUAL DEL USUARIO

EN
Thank you for choosing the HBK-R01 remote control provided by us.
Precaution
For avoidance of damage to the product or injury to the people, please carefully read this manual before use and keep it for further reference.
! Warnings
· For avoidance of damage to the product, do not expose the product to rain or damp.
· This product is only for indoor use. · Please use a combination of transmitter and receiver provided
by us as we can’t guarantee our transmitters or receivers are fully compatible with other manufacturers products. · The product installation shall be conducted by a professional electrician as it requires specialized knowledge. Incorrect operation may damage the product, or make it inoperable. · The transmitter and receiver have been paired with each other in factory. · Keep this product away from children under 3 year old to prevent ingestion. · Install the receiver in a place out of touch of children, so as to prevent electric shock. · Please do not put the battery in water, fire or moisture places for avoidance of explosion. · The battery contains hazardous substance. Return the waste batteries to the recycling bin to avoid contamination to the environment.
1

EN

Features
· aSpppelciHeiadolitzomeodethfoeSrretfiheceludascr.cietsys Ccoanmtroel sryastem and unable to be
· Support connecting external access control keypad. (Remarks: Access control keypad is excluded.)
· Built-in buzzer makes sound to remind people when the door is locked or unlocked.
· Built-in diode, real-time protecting electric lock, prolonging the service life.
HBK-R01 REMOTE CONTROL

Buzzer

Access Keypad Port

Indicator Light

Lock Type
Remote Pairing Exit Button Port Power Port

Buzzer Operating Mode
Time Delay
Lock Port

2

EN
Specifications

Receiver

Operating Voltage: 12VDC

Output Current: 1A

Operating Environment: Indoor Lock Output Port: 1

Exit Button Output Port: 1

Keypad Connection Port: 1

RF Frequency: 433.92MHz Transmitter Support: Max. 40

RF Channel: 1 Operating Current: 20mA

Time Delay: 0/5/10 seconds Built-in Buzzer: Yes DC Encoding Type: Learning Code

Enclosure Material: ABS Plastic Ambient Humidity: 0%RH-95%RH(Non-condensing) Ambient Temperature: -22°F to 140°F

Operating Method: RF Remote

Operating Distance: 164 feet without block Operating Mode: Momentary/Toggle/Latched

Dimensions: 3-37/64″x 2-21/64″x 1-9/64″ [91x59x29mm] Transmitter
Operating Current: 10mA Enclosure Material: ABS Plastic

Batteries Type: CR2016 (Built-in) Transmitting Frequency: 433.92MHz

Operating Voltage: 6VDC (Powered by 2pcs CR2016 batteries)

3

EN

Wiring Diagram

  1. Connect Fail-Secure Lock

Access Keypad

+12V GND PUSH COM

Input

Select NO

V+ V-

Exit Button
4

Fail-secure Lock

EN

  1. Connect Fail-Safe Lock

Access Keypad

+12V GND PUSH COM

Input

Select NC

V+ VNO COM NC

Exit Button
5

Fail-safe Lock

EN
Operating Settings 1) Remote Pairing
Tap RF icon followed by press the button on the transmitter within 20 seconds. 2) Unpairing Tap and hold RF icon for 5 seconds. Remarks: The operation will clear all paired transmitters, please
operate with caution.

NO NC

LOCK TYPE

RF

  1. Lock Type Setting

NO: Fail-Secure Lock

NC: Fail-Safe Lock

Remarks: Incorrect setting will affect operating of the lock,

please confirm the lock type before setting.

NO NC

LOCK TYPE

RF

6

EN 4) Buzzer Setting
ON: Enable. OFF: Disable.
5) Operating Mode Select Momentary: Press button A for ON, Release button A for OFF. Latched: Press button A for ON, press button B for OFF. Toggle: Press button A for ON, press button A again for OFF. Remarks: Latched is only valid when using a transmitter with 2-buttons.
7

EN 6) Time Delay Setting
Support 0/5/10 seconds time delay. Remarks: Only available when Momentary selected.
Trouble Shooting 1. Q: Why does not the transmitter’s LED light up when I press
the button on it ? A: The battery power may be exhausted. Please replace the battery. 2. Q: Why can’t the lock be unlocked after pressing the transmitter? A: Please check the issue by the following steps:
a. Check whether the remote control receiver and transmitter are paired successfully. b. Check whether there is any metal object around the remote control receiver as it may shield the signal. 3. Q: Why can’t the lock work properly when the wiring is correct? A: Please check whether the indicator of the receiver is on and the mode of lock is selected correctly. (For more details, please refer to ‘Lock Type Setting’ in this manual.)
8

EN
Fcc Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter mined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.
9

ES
Gracias por elegir el mando a distancia HBK-R01 que le proporcionamos.
Precaución
Para evitar daños en el producto o en las personas, lea atentamente este manual antes de utilizarlo y consérvelo para futuras consultas.
! Advertencias
· Para evitar daños en el producto, no lo exponga a la lluvia o a la humedad.
· Este producto es sólo para uso en interiores. · Por favor, utilice una combinación de transmisor y receptor
proporcionada por nosotros, ya que no podemos garantizar que nuestro transmisor o receptor sea totalmente compatible con los productos de otros fabricantes. · La instalación del producto debe ser realizada por un electricista profesional, ya que requiere conocimientos especializados. Una operación incorrecta puede dañar el producto o hacerlo inoperable. · El emisor y el receptor vienen emparejados de fábrica. · Mantenga este producto fuera del alcance de los niños menores de 3 años para evitar su ingestión. · Instale el receptor en un lugar fuera del alcance de los niños, para evitar descargas eléctricas. · Por favor, no coloque la batería en lugares con agua, fuego o humedad para evitar una explosión. · La batería contiene sustancias peligrosas. Devuelva las pilas usadas al contenedor de reciclaje para evitar la contaminación del medio ambiente.
10

ES
Características
· EasppliecHcaioraslmeizaaedootSrpoeascrcauaemrl pistiosyste. Cmaa mdeecornatrol de acceso e incapaz de
· Soporta la conexión de un teclado de control de acceso externo. (Nota: se excluye el teclado de control de acceso).
· El zumbador incorporado emite un sonido para recordar cuando la puerta está bloqueada o desbloqueada.
· Diodo incorporado, protección en tiempo real de la cerradura eléctrica, prolongando la vida útil.

HBK-R01 CONTROL REMOTO

Zumbador

Acceso al puerto del teclado

Luz indicadora

Tipo de cerradura
Emparejamiento remoto Puerto del botón de salida Puerto de alimentación
11

Zumbador Modo de funcionamiento
Tiempo de retraso Puerto de la cerradura

ES
Especificaciones

Receptor

Tensión de entrada: 12VDC

Corriente de salida: 1A

Puerto de conexión del teclado: 1 Canal RF: 1

Botón de salida Puerto de salida: 1 Bloqueo del puerto de salida: 1

Soporte para transmisores: Max. 40 Frecuencia RF: 433,92MHz

Corriente de funcionamiento: 20mA Zumbador incorporado: Sí

Entorno de funcionamiento: Interior

Tiempo de retardo: 0/5/10 segundos

Material de la carcasa: Plástico ABS

Tipo de codificación DC: Código de aprendizaje

Humedad ambiente: 0%RH-95%RH (sin condensación)

Temperatura ambiente: -22°F a 140°F

Método de funcionamiento: Transmisor RF

Distancia de funcionamiento: 164 pies sin bloque

Modo de funcionamiento: Momentáneo / Alternado / Bloqueado

Dimensions: 3-37/64″x 2-21/64″x 1-9/64″ [91x59x29mm]

Transmisor

Corriente de funcionamiento: 10mA

Material de la carcasa: Plástico ABS

Tipo de pilas: CR2016 (incorporada)

Frecuencia de transmisión: 433,92MHz

Tensión de funcionamiento: 6VDC (alimentado por 2 pilas CR2016)

12

ES

Diagrama de cableado

  1. Conexión Cerradura Fail-Secure

Teclado de acceso

+12V GND PUSH COM

Entrada

Seleccione NO

V+ V-
Botón de salida Bloqueo Fail-Secure
13

ES

  1. Conexión Cerradura Fail-Safe

Teclado de acceso

+12V GND PUSH COM

Entrada

Seleccione NC

V+ VNO COM NC
Botón de salida Bloqueo Fail-Safe
14

ES
Ajustes de funcionamiento

  1. Emparejamiento remoto Pulse el icono RF y, a continuación, pulse el botón del transmisor antes de que transcurran 20 segundos.
  2. Desempeñando Mantenga pulsado el icono RF durante 5 segundos. Nota: Esta operación borrará todos los transmisores emparejados, por favor opere con precaución.

NO NC

LOCK TYPE

RF

  1. Ajuste del tipo de cerradura

NO: Bloqueo Fail-Secure

NC: Bloqueo Fail-Safe

Nota: Un ajuste incorrecto afectará al funcionamiento de la cerradura, por favor confirme el tipo de cerradura antes de

ajustarla.

NO NC

LOCK TYPE

RF

15

ES 4) Ajuste del zumbador
ON: Habilitar OFF: Desactivar
5) Selección del modo de funcionamiento Momentáneo: Pulse el botón A para ON, suelte el botón A para OFF. Bloqueado: Pulse el botón A para ON, pulse el botón B para OFF. Alternado: Pulse el botón A para ON, pulse de nuevo el botón A para OFF. Nota: El bloqueado sólo es válido cuando se utiliza un transmisor con 2 botones.
16

ES 6) Ajuste del tiempo de retardo
Soporta un retardo de 0/5/10 segundos. Nota: Sólo está disponible cuando se selecciona Momentáneo.
Solución De Problemas 1. Q: Por qué no se enciende el LED del transmisor cuando presiono
el botón en él? A: La energía de la batería puede estar agotada. Reemplace la batería. 2. Q: Por qué no se puede desbloquear la cerradura después de pre-
sionar el transmisor? A: Verifique el problema mediante los siguientes pasos: a. Compruebe si el receptor y el transmisor del control remoto están
emparejados correctamente. b. Compruebe si hay algún objeto metálico alrededor del receptor
del control remoto, ya que puede bloquear la señal. 3. Q: Por qué la cerradura no puede funcionar correctamente cuando
el cableado es correcto? A: Compruebe si el indicador del receptor está encendido y si el
modo de bloqueo está seleccionado correctamente. (Para obtener más detalles, consulte ‘Ajuste del tipo de cerradura’ en este manual).
17

ES
Adver tencia FCC
Este dispositivo cumple con la parte 15 de las reglas FCC. La operación está limitada por dos condiciones: (1) el dispositivo no puede causar interferencia perjudicial, y (2) el dispositivo debe aceptar cualquier interferencia recibida, incluyendo cualquier interferencia que pueda causar un funcionamiento inesper-ado. Cualquier cambio o modificación que no haya sido expresamente aprobada por la parte responsable de la OCDEpuede dar lugar a la invalidación de la autoridad del usuario para operar el equipo.
Nota: De conformidad con la parte 15 de las normas FCC, este equipo ha sido probado para cumplir los límites de los dispositivos digitales de clase B. Estas restricciones tienen por objeto proporcionar una protección razonable contra las perturbaciones perjudiciales en las instalaciones residenciales. El equipo genera, utiliza y irradia energía de radiofrecuencia que puede causar interferencias perjudiciales en las comunicaciones de radio si no se instala y utiliza de acuerdo con las instrucciones. Sin embargo, no hay garantía de que no haya inter-ferencia en una instalación en particular. Si el dispositivo causa una interferencia perjudicial en la recepción de radio o televisión, puede determinarse apagando y encendiendo el dispositivo, alentando al usuario a tratar de corregir la interferencia mediante una o más de las siguientes medidas: — Reorientar o reubicar la antena receptora. — Aumentar la distancia entre el dispositivo y el receptor. — Conecte el dispositivo a un enchufe diferente del circuito conectado al receptor. — Consulte a su distribuidor o técnico de radio / televisión experimentado para obtener ayuda. Para cumplir con las directrices de exposición a radiofrecuencia de la FCC, este dispositivo debe instalarse y funcionar a una distancia mínima del radiador, es decir, a 20 cm de su cuerpo: utilice sólo las antenas proporcionadas.
18

C 2023 HOBK Electronic Technology Co., Ltd All rights reserved

75% recycled paper

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals