UHPPOTE HBK-A01 Access Control Keypad User Manual
- June 16, 2024
- UHPPOTE
Table of Contents
- UHPPOTE HBK-A01 Access Control Keypad
- Product Information
- Product Usage Instructions
- Packing List
- Introduction
- Features
- Specifications
- Installation
- Wiring Diagram
- Sound and Light Indication
- Operation Guide
- Basic Operation
- Troubleshooting
- FCC WARNING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UHPPOTE HBK-A01 Access Control Keypad
Product Information
Specifications
- Operating Voltage: 12VDC
- Lock Output Load: Max. 1.5A
- Card Capacity: 500
- Card Type: Standard 125KHz EM
- PIN Capacity: 500
- Door Open Time: 0-99 seconds
- Idle Current: 50mA
- Operating Humidity: 10%-90%RH
- Waterproof: No
- Enclosure Material: ABS Plastic
- Product Weight: 100g
- Enclosure Size: 100x100x18.5mm
- Wiring Connections: Electric Lock, Exit Button, External Bell
Product Usage Instructions
Installation
- Remove the back cover from the keypad.
- Drill 4 holes on the wall for the self-tapping screws and 1 hole for the cable.
- Put the supplied plastic anchors into the 4 holes.
- Fix the back cover firmly on the wall with 4 self-tapping screws.
- Thread the cable through the cable hole.
- Attach the keypad to the back cover.
Wiring Diagram
-
Common Power Supply Diagram:
-
Special Power Supply Diagram:
Sound and Light Indication
Operation Status | LED Indicator | Buzzer |
---|---|---|
Standby | White | A short beep |
Press # | Red | A short beep |
Press # # | Flash yellow | A short beep |
In the programming mode | Yellow | Flash blue |
PIN only mode | Blue | Green |
Other mode | Blue | Green |
The menu is waiting to be selected | F1latimshegreen | A short beep |
The menu selected | Flash red 3 times | 3 short beeps |
Unlock the lock | – | A short beep |
Enter the PIN | – | A short beep |
Operation successful | – | A short beep |
Operation failed | – | Press digit key |
Operation Guide
-
Purpose: To enter the programming mode
-
Operation: # Admin Code #
-
Remarks: The default admin code is 123456.
-
Purpose: To return to the previous menu in the programming mode
-
Operation: #
- Purpose: To exit from the programming mode
-
Operation: *
The following operations must be done in the programming mode:- Purpose: To change the admin code
-
Operation: New Admin Code # Repeat New Admin Code #
- Remarks: The admin code can be 4-8 digits long.
- Purpose: To read card users
-
Operation: Read Card N #
- Purpose: To add card users
-
Operation: Add users
- Remarks: Add a card user with ID number by using the following operation: User ID Number # Read Card #
- Purpose: To add or change a PIN user
-
Operation: User ID Number # PIN #
- Remarks: The user ID number is any 4-digit number from 0001 to 9999. Users can be added continuously by repeating the operation.
FAQ
-
Q: What is the operating voltage of the product?
A: The operating voltage is 12VDC. -
Q: What is the maximum lock output load?
A: The maximum lock output load is 1.5A. -
Q: What is the card capacity?
A: The card capacity is 500. -
Q: What type of cards does it support?
A: It supports Standard 125KHz EM cards. -
Q: What is the PIN capacity?
A: The PIN capacity is 500. -
Q: What is the door open time range?
A: The door open time range is 0-99 seconds. -
Q: Is the product waterproof?
A: No, the product is not waterproof. -
Q: What is the enclosure material of the product?
A: The enclosure material is ABS Plastic. -
Q: What is the weight of the product?
A: The product weight is 100g. -
Q: What are the dimensions of the enclosure?
A: The enclosure size is 100x100x18.5mm. -
Q: What are the wiring connections required?
A: The wiring connections required are for the electric lock, exit button, and external bell.
USER MANUAL
Packing List
| Operating Voltage| 12VDC| Lock Output Load| Max. 1.5A|
---|---|---|---|---|---
Card Capacity| 500| Card Type| Standard 125KHz EM
| PIN Capacity| 500| Door Open Time| 0-99 seconds|
Card Reading Distance| Max. 6cm| Operating Temperature| -22°F-140°F
| Idle Current| 50mA| Operating Humidity| 10%-90%RH|
Waterproof| No| Enclosure Material| ABS Plastic
Product Weight| 100g| Enclosure Size| 100x100x18.5mm
Wiring Connections| Electric Lock, Exit Button, External Bell
Introduction
This RFID card access control unit controls 1 door. It uses ST MCU to ensure stable performance, and low-power circuit makes the service life longer. OMRON power relay with 10A switching capacity provides an excellent switching performance for electric locks. It is widely used in factories, houses, residential quarters, offices, mechanical and electrical control equipment and so on.
Features
- Full programming from the keypad.
- Supports Card, PIN, Card + PIN, Card or PIN.
- Can be used as standalone keypad.
- Adjustable door open time.
- Very low power consumption.
- Lock output current short circuit protection.
- With bell function, supports external bell.
- Adopt the switch mode power supply (SMPS) solution.
- Built-in buzzer.
- Red, blue, white, yellow and green LED indicators display the working status.
Specifications
| Operating Voltage| 12VDC| Lock Output Load| Max. 1.5A|
---|---|---|---|---|---
Card Capacity| 500| Card Type| Standard 125KHz EM
| PIN Capacity| 500| Door Open Time| 0-99 seconds|
Card Reading Distance| Max. 6cm| Operating Temperature| -22°F-140°F
| Idle Current| 50mA| Operating Humidity| 10%-90%RH|
Waterproof| No| Enclosure Material| ABS Plastic
Product Weight| 100g| Enclosure Size| 100x100x18.5mm
Wiring Connections| Electric Lock, Exit Button, External Bell
Installation
- Remove the back cover from the keypad
- Drill 4 holes on the wall for the self-tapping screws and 1 hole for the cable Put the supplied plastic anchors into the 4 holes
- Fix the back cover firmly on the wall with 4 self-tapping screws
- Thread the cable through the cable hole
- Attach the keypad to the back cover
Wiring Diagram
- Common Power Supply Diagram:
- Special Power Supply Diagram:
Sound and Light Indication
Operation Guide
The following operations must be done in the programming mode
Basic Operation
Advanced Application
Alarm Setting
Troubleshooting
-
Q: Why can’t the door be unlocked after I swipe an added card?
A: Please check weather you have set the door open mode to entry by PIN only. -
Q: Why is there no sound when I press the numeric keypad?
A: Please check wether you have disabled buzzer. If yes, please enable buzzer according to the operation guide. -
Q: Why there are 3 short beeps when I try to add a card user in the programming mode?
A: This card has been added already. -
Q: Why isn’t the door unlocked when the LED indicator keeps flashing green after I swipe the added card?
A: You have set the door open mode to entry by Card and PIN, please unlock the door by using card and PIN together. -
Q: How to replace the card which was corresponding to a certain user ID number?
A: Please delete this user ID number firstly and then re-add it.
FCC WARNING
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.
2022 HOBK Electronic Technology Co., Ltd
All rights reserved
75% recycled paper
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>