Packing List
Name | Quantity | Remarks |
---|---|---|
Access Keypad | 1 | |
Connector with cable of 9-27/32″ | 1 | |
User Manual | 1 | English |
Plastic Anchors | 4 | Ø6mmx25mm, used for fixing |
Self – Tapping Screw | 4 | Ø 4mmx25mm, used for fixing |
Introduction
This RFID card access control unit controls 1 door. It uses ST MCU to ensure
stable performance, and low-power circuit makes the service life longer.
OMRON power relay with 10A switching capacity provides an excellent switching
performance for electric locks. It is widely used in factories, houses,
residential quarters, offices, mechanical and electrical control equipment and
so on.
Features
- Full programming from the keypad.
- Supports Card, PIN, Card + PIN, Card or PIN.
- Can be used as standalone keypad.
- Adjustable door open time.
- Very low power consumption.
- Lock output current short circuit protection.
- With bell function, supports external bell.
- Adopt the switch mode power supply (SMPS) solution.
- Built-in buzzer.
- Red, blue, white, yellow and green LED indicators display the working status.
Specifications
Operating Voltage | 12VDC | Lock Output Load | Max. 1.5A |
---|---|---|---|
Card Capacity | 1000 | Card Type | Standard 125KHz EM |
PIN Capacity | 500 | Door Open Time | 0-99 seconds |
Card Reading Distance | Max. 6cm | Operating Temperature | -40°F-140°F |
Idle Current | 50mA | Operating Humidity | 10%-90%RH |
Waterproof | No | Enclosure Material | ABS Plastic |
Product Weight | 3.53oz | Dimensions | 4-21/64″x2-51/64″x29/32″ |
Wiring Connections | Electric Lock, Exit Button, Bell |
Installation
- Remove the back cover from the keypad
- Drill 4 holes on the wall for the self-tapping screws and 1 hole for the cable
- Put the supplied plastic anchors into the 4 holes
- Fix the back cover firmly on the wall with 4 self-tapping screws
- Thread the cable through the cable hole
- Attach the keypad to the back cover
Wall
Wiring Diagram
Common Power Supply Diagram
Special Power Supply Diagram
Wiring harness Connections:
+12V: RED | OPEN: YELLOW | NO: BLUE | NC: BROWN |
---|---|---|---|
GND: BLACK | PUSH: GREEN | COM: WHITE | BELL: PINK |
Sound and Light Indication
Operation Status | LED Indicator | Buzzer |
---|---|---|
Standby | PIN only mode | White |
Other mode | Red | |
Press # | Flash yellow | |
Press # # | Yellow |
In the programming
mode| When a menu is waitingto be selected| Flash blue|
The menu selected| Blue|
Unlock the lock| | Green| A short beep
Enter the PIN| | Blue|
Operation successful| | Flash green
1 time| A short beep
Operation failed| | Flash red
3 times| 3 short beeps
Press digit key| | | A short beep
Operation Guide
Purpose | Operation | Remarks |
---|---|---|
Enter the programming mode | # Admin Code # | The default admin code is 123456. |
Return to previous menu in the programming mode | # | |
Exit from the programming mode | * |
The following operations must be done in the programming mode
Basic Operation
Change the admin code| 0| New Admin Code#
Repeat New Admin Code #| The admin code can be 4-8 long.
Add users| 1| 0 Read Card 1 Read Card 2
Read Card N # ……| Add card users
1 User ID Number # Read Card #| Add a card user with ID number
2 User ID Number # PIN #| Add or change a PIN user
| The user ID number is any 4-digit number from 0001 to 9999.
Users can be added continuously by repeating the operation.
Delete users| 2| 0 Read Card 1 Read Card 2 ……
Read Card N #| Users can be deleted continuously.
1 User ID Number #| The cards can be deleted when broken or lost.
2 8 digits or 10 digits card number #| For example, the card number is
0006307890
09616434, can input 0006307890 or 09616434.
3 0000 #| Delete all users.
Attention: Delete all PIN users & card users except
the super open code.
Set super open code| 3| Super Open Code #
Repeat Super Open Code #| Support one set super open code which can be used to
open the door in any open mode.
0000 #| Delete the super open code
Set open mode| 4| 0 #| Entry is by either Card or PIN (Default)
1 #| Entry is by Card and PIN together
2 #| Entry is by PIN only
3 #| Entry is by Card only
Set open time| 5| XX #| XX is any number from 0 to 99.
The factory default setting is 3 seconds.
Advanced Application
6| 1| XX #| Set Multi-cards to open| XX is any number from 1 to 10.
Only for Card Only mode.
The door will opened only when the quantity of valid cards read .
2| 1 Read Card#| Set admin add card| Support one admin add card and
one delete card each.
2 Read Card#| Set admin delete card
0 #| Delete admin cards
Alarm Setting
7| 1| 0 #| Set anti-tamper alarm| OFF (Default)
| | 1 #| ON
System Setting
8| 1| 0 #| Set keypad
output mode| Set to Normal Mode.
The door will locked automatically after an unlock operation.
| 1 #| Set to Toggle Mode.
The door will keep unlocking until next unlock
operation.
Optional Setting
9| 1| 0 #| Set buzzer| ON (Default)
1 #| OFF
2| 0 #| Set keypad
backlight| ON (Default)
| | 1 #| OFF
| | 2 #| Auto Mode
Remark: All code can be 4 to 8 digits long except every as zero.
The following operations must be done out of programming mode
Set the code of an added card | # # Read an Added Card PIN # Repeat PIN # |
---|---|
Reset to defauladmin code | 1. Disconnect the power. |
2 Press 00 # within 5 seconds . after the HBK-A02 is powered on. | Resets |
the admin code to 123456.
Reset to default setting| 1. Disconnect the power.
2. Press 99 # within 5 seconds after the HBK-A02 is powered on.| Resets the
device to the factory default settings.
Unlock the Lock
For a PIN user | Input# , then press PIN |
---|---|
For a Card user | Read Card |
For a Card and
PIN user| (the LED indicator flashes green), then input Read Card PIN #
Troubleshooting
-
Q: Why can’t the door be unlocked after I swipe an added card?
A: Please check whether you have set the door open mode to entry by PIN only. -
Q: Why is there no sound when I press the numeric keypad?
A: Please check whether you have disabled buzzer. If yes, please enable buzzer according to the operation guide. -
Q: Why there are 3 short beeps when I try to add a card user in the programming mode?
A: This card has been added already. -
Q: Why isn’t the door unlocked when the LED indicator keeps flashing green after I swipe the added card?
A: You have set the door open mode to entry by Card and PIN, please unlock the door by using card and PIN together. -
Q: How to replace the card which was corresponding to a certain user ID number?
A: Please delete this user ID number firstly and then re-add it.
FCC Warning
FCC ID: 2A4H6HBK-A01
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipmentinto an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.
We Create Security
© 2022 HOBK Electronic Technology Co., Ltd
All rights reserved