HALO RSQ5 Celling Light Instruction Manual
- June 16, 2024
- HALO
Table of Contents
IB518094ML
RSQ5 Square Instructions
Packaging Contents
ITEMS REQUIRED
(Purchase separately)
- Screwdriver
- Gloves
- Ladder
IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:
-
Heed all warnings, including below warnings AND those included on product.
-
HALO® recessed luminaires (fixtures) are designed to meet the latest NEC requirements and are certified in full compliance with UL. Before attempting installation of any recessed lighting luminaire check your local electrical code. This code sets the wiring standards for your locality and should be carefully studied before starting.
-
Read and follow these instructions.
Risk of Fire – MINIMUM 90°C SUPPLY CONDUCTORS. If uncertain, consult an
electrician.
Risk of Electric Shock – To avoid possible electrical shock, be sure that
power supply is turned off at fuse box or circuit breaker before installing or
servicing luminaire.
Risk of Fire/Electric Shock –
Please consult an electrician for installation if uncertain of luminaire
electrical systems.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Edges may be Sharp –
Wear gloves while handling.
- Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids the warranty.
- Fixture should be installed by persons with experience in household wiring or by a qualified electrician. The electrical system, and the method of electrically connecting the fixture to it, must be in accordance with the National Electrical Code and local building codes.
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- This device complies with ISED ICES Standard Canada ICES-005(B) / NMB-005 (B).
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- Please examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts prior to installation of the retrofit kit.
- This device is not intended for use with emergency exits.
- For Canada only per CSA C22.2 No. 250.1-16, retrofits for luminaire conversion: The retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by authorities having jurisdiction. Product must be installed by a qualified electrician in accordance with the applicable and appropriate electrical codes. The installation guide does not supersede local or national regulations for electrical installations.
SAVE THESE INSTRUCTIONS AND WARNINGS.
DEDICATED LED LUMINAIRES
Risk of Fire/Electric Shock –
- LED connector is compatible with Halo 5” H550 and Halo E550 Series LED luminaires.
- LED connector meets California Title-24 high-efficacy luminaire standard as a non-screw base socket.
- LED connector is a non-screwbase luminaire disconnect for tool-less installation.
The RSQ5 is UL Certified for use with any 5” diameter recessed luminaire constructed of steel or aluminum with an internal volume that exceeds 97.4 in3 addition to those noted below and does not exceed the input rating of the luminaire.
- HALO: H5ICAT, H5RICAT, H5T, H5RT, H5TM, H25ICAT, E5ICAT, E5ICATNB, E5RICAT, E5RTAT, E5TAT, E5TATNB
- HALO LED : H550ICAT, H550RICAT, E550ICAT, E550RICAT
- ALL-PRO™: EI500AT, ET500, EI500RAT, ET500R
- Juno: IC20, IC20R, IC25, IC25R, IC25W, IC25S, TC20, TC20R
- Lightolier: 1004ICS, 1004ICR, 1004SIC, 1004SICR
- Capri: R5
- Elite: B5ICAT, B5RICAT, B5, B5R
- Elco: (HL7ICA) EL7ICA
Requires replacement of torsion springs with friction blades (included).
DIMMING
The Halo LED luminaire can be dimmed with phase-control dimmers (leading
edge and trailing edge phase cut). Refer to product specifications and dimming
information at www.cooperlighting.com; and
consult the dimmer manufacturer for their latest dimmer listings, load ratings
and product information.
WIRE INSTALLATION
Before proceeding, confirm luminaire is compatible with RSQ5. A listing of the
most common luminaires are provided in the Recessed Luminaires section of
these instructions.
Ground Wire Installation
For ground connection from LED module to the housing, use provided green
ground wire (factory installed) as shown in Figure 1 and connect via one of
the three following connection methods:
- Use supplied #8-32 screw (Figure 2)
- Use supplied #8 nut (Figure 3)
- Use supplied #8-32 screw into existing hole inside the luminaire (Figure 4)
Note: If no hole exists, drill a small pilot hole and use the provided #8 sheet metal screw.
Retrofit Installation Into E26 Edison Screw Base Recessed Luminaires
- Remove mounting bracket and plate from inside existing recessed luminaire (if installed).
- Remove socket from plate (if installed).
- Screw Edison base adapter (F) into existing Edison base socket in luminaire (Figure 5).
- Plug the orange connector on RSQ5 LED module (A) into the orange connector included with the screw base adapter (F) (Figure 6).
- Bundle any excess length of wire inside the luminaire (above the module) in preparation for insertion.
- Install the module. (See MOUNTING section for specific instructions)
Installation Into Halo H550x and E550x Series LED (Non-Screw Base) Luminaires
- Plug the orange connector on RSQ5 LED module (A) into the orange connector included with the luminaire (Figure 6).
- Bundle any excess length of wire inside the luminaire (above the module) in preparation for insertion.
- Install the module. (See MOUNTING section for specific instructions)
MOUNTING
Regardless of method selected a round foam gasket has been provided for
installation if local code requires.
Torsion Spring Installation Method
- Properly wire the unit as instructed in the WIRING section of these instructions.
- If the torsion springs are not pre-installed from the factory, then remove the torsion springs and screws from the separate parts bag and install them to the ends of the center bracket as shown in Figure 8.
- For installation into a 5” luminaire, simply press each leg of the torsion springs together and insert them through the receivers inside the luminaire. (Figure 7)
Note : For easiest installation, insert both sides of the torsion springs simultaneously (versus one at a time).
RSQ5 Square Trim Alignment: (Figure 14)
- With torsion spring installations the RSQ5 square trims can be rotated up to 90 degrees, after installation into the ceiling, for alignment to walls or décor.
Friction Clip Installation Method
For 5” housings without torsion spring receiving brackets (see in the HOUSINGS
section of these instructions for a listing of the most common housings):
RSQ5 Square Trim Alignment: (Figure 14)
- With friction clip installations the RSQ5 square trims can be aligned to wall or décor using the following methods.
- For slight adjustments to alignment of square trims to walls, twist square trim ring slightly to align with wall.
- If larger adjustments are necessary, remove entire LED module and reposition relative to wall for proper alignment.
Edges may be Sharp –
Wear gloves while handling.
- Remove torsion spring brackets completely (keep screws) (see Fig. 8).
- Attach friction blade to module bracket (use screws removed from torsion spring brackets) (See Figure 9).
- Repeat for second blade.
REPLACING LED MODULE
- With fingertips, pull down firmly on trim ring until module is removed from the housing.
- While wearing gloves, squeeze torsion springs together to remove LED module. If using friction blades, pull module out of housing slowly.
- Disconnect LED module wiring from recessed can. (LED connector or screw-in Edison base).
REPLACING BAFFLE
The RSQ5 comes with a baffle trim that may be replaced in the field.
- Rotate locking levers Clockwise to unlock. (Fig. 10)
- Separate module from trim. (Fig. 11)
- Align replacement trim making certain the large tabs align with large notches in module and small tabs align with small notches (Fig. 12) and place module on to trim.
- Rotate locking levers Counter Clockwise to lock trim to module (Fig. 13).
FOR RSQ5 SELECTABLE CCT VERSIONS ONLY.
5-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE.
Cooper Lighting Solutions warrants to customers that, for a period of five
years from the date of purchase, Cooper Lighting Solutions products will be
free from defects in materials and workmanship.
The obligation of Cooper Lighting Solutions under this warranty is expressly
limited to the provision of replacement products. This warranty is extended
only to the original purchaser of the product. A purchaser’s receipt or other
proof of date of original purchase acceptable to Cooper Lighting Solutions.
This is required before warranty performance shall be rendered.
This warranty does not apply to Cooper Lighting Solutions products that have
been altered or repaired or that have been subjected to neglect, abuse, misuse
or accident (including shipping damages). This warranty does not apply to
products not manufactured by Cooper Lighting Solutions which have been
supplied, installed, and/or used in conjunction with Cooper Lighting Solutions
products. Damage to the product caused by replacement bulbs or corrosion or
discoloration of brass components are not covered by this warranty.
LIMITATION OF LIABILITY:
IN NO EVENT SHALL COOPER LIGHTING SOLUTIONS BE LIABLE FOR SPECIAL, INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION,
WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR
FOR LOST PROFITS; NOR SHALL THE LIABILITY OF COOPER LIGHTING SOLUTIONS FOR ANY
CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE
MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF
COOPER LIGHTING SOLUTIONS PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS
THEREFORE, EXCEED THE PURCHASE PRICE OF COOPER LIGHTING SOLUTIONS PRODUCTS
GIVING RISE TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL
FIXTURES.
All returned products must be accompanied by a Return Goods Authorization
Number issued by the Company and must be returned freight prepaid. Any product
received without a Return Goods Authorization Number from the Company will be
refused.
Cooper Lighting Solutions is not responsible for merchandise damaged in
transit. Repaired or replaced products shall be subject to the terms of this
warranty and are inspected when packed.
Evident or concealed damage that is made in transit should be reported at once
to the carrier making the delivery and a claim filed with them.
Reproductions of this document without prior written approval of Cooper
Lighting Solutions are strictly prohibited.
FCC Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off an on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2020 Cooper Lighting Solutions
All Rights Reserved
Printed in China
Publication No. IB518288ML
Cooper Lighting Solutions is a registered trademark.
All trademarks are property of their respective owners.
Product availability, specifications, and compliances are subject to change
without notice
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>