Voltage: 24 Vdc
Maximum consumption : 0.15 A
C NC NO contact output: 30Vdc 1A
Max. cable section for clamps: 0.8 mm²
Operating temperature: (- 40) – (+ 70) °C
IP degree of protection: 54*
IK degree of protection: 07
Camera resolution : 1080 p
Camera viewing field angle: H= 80°; V= 53°
Badge reader Frequency: 13.56 MHz
Badge reader transmission power: < 42 dBuA/m @ 10m

  • Only for indoor installation

Dimensional data

A B C D E F
94 mm 193 mm 60.06 mm 10 mm 20.6 mm 34.6 mm

Front view

Legend

  1. LED for the shooting field lighting
  2. Camera
  3. Light sensor
  4. Badge reader for door lock opening
  5. Microphone
  6. Call key
  7. Guard station call key
  8. Loudspeaker

Rear view

Legend

  1. RJ45 Connector (*)
  2. Connection clamp
  3. Mounting bracket
  4. Locking screw
  5. Tamper switch
    (*) This device does not support standard POE power supplies, but only POE power supplies identified with item no. 375002. Connect the cat5/5e/6 FTP or cat5/5e/6 UTP cable with ferrite supplied to the connector.

Connection clamps

GND system common ground terminal for RS485 connection
SENSE door lock status signal input (dry contact)
LOCK- electric door lock connection and control (12V – 4A impulsive on 3 Ohm

maximum)
LOCK+
FIRE Linkage –GND| local door lock release pushbutton connection for firealarm system
+12V| access control devices power supply
NO| interlocked contact
COM
NC
DC24V| additional power supply clamps (not polarized)

Configuration

To use the device, it is necessary to configure it and create the Community structure using the IP DES System software, following the steps below:

For further information, please refer to the IP DES System Software Manual and Small video entrance panel manual, available for download from www .homesystems-legrandgroup.com website

Wiring diagrams

CABLES LEGEND

|

LAN PoE BTicino

|

LAN Ethernet

|

Copper cables

|

2 x Copper cables

---|---|---|---|---

It is possible to use two different types of connection according to installation situation:

  • A – Diagram with power supply by BTicino PoE Switch

  • B – Diagram with local power supply

Attention : this device does not support standard POE power supplies, but only POE power supplies identified with 375002. Connect the cat5/5e/6 FTP or cat5/5e/6 UTP cable with ferrite supplied to the connector.
Attention : do not directly connect PoE ports to an unsuitable network interface, such as a device powered by a different voltage. Connect the UP LINK port to a suitable port, never to a PoE port.
Note : maximum length of every LAN permanent link line = 90 m.

Ethernet connection

CABLES LEGEND|

LAN PoE Standard

|

LAN PoE BTicino

| LAN Ethernet | Copper cables |

2 x Copper cables

---|---|---|---|---|---

Attention: do not directly connect PoE ports to an unsuitable network interface, such as a device powered by a different voltage. Connect the UP LINK port to a suitable port, never to a PoE port.
Note : to connect the devices it is possible to use both types of wiring (diagram A or diagram B) or even  mixed ones.

Fiber optic riser connection (case of higher bandwidth demand)

CABLES LEGEND

|

LAN PoE Standard

|

LAN PoE BTicino

|

LAN Ethernet

|

Optical fiber

| Copper cables | 2 x Copper cables
---|---|---|---|---|---|---

Attention : do not directly connect PoE ports to an unsuitable network interface, such as a device powered by a different voltage. Connect the UP LINK port to a suitable port, never to a PoE port.
Note : to connect the devices it is possible to use both types of wiring (diagram A or diagram B) or even mixed ones.

Available functions

CABLES LEGEND

|

LAN PoE BTicino

|

LAN Ethernet

|

Copper cables

| 2 x Copper cables
---|---|---|---|---

Attention : do not directly connect PoE ports to an unsuitable network interface, such as a device powered by a different voltage. Connect the UP LINK port to a suitable port, never to a PoE port.
Note : to connect the devices it is possible to use both types of wiring (diagram A or diagram B) or even mixed ones.

References