addon CAB-O-8S-200G-2M-AO Compatible TAA Compliant 200GBase-CU OSFP to 8xSFP28 Direct Attach Cable Instruction Manual

June 4, 2024
addon

addon CAB-O-8S-200G-2M-AO Compatible TAA Compliant 200GBase-CU OSFP to 8xSFP28 Direct Attach Cable Instruction Manual
addon CAB-O-8S-200G-2M-AO Compatible TAA Compliant 200GBase-CU OSFP to
8xSFP28 Direct Attach Cable

CAB-O-8S-200G-2M-AO
Arista Networks® CAB-O-8S-200G-2M Compatible TAA Compliant 200GBase-CU OSFP to 8xSFP28 Direct Attach Cable (Passive Twinax, 2m)

Features

  • OSFP MSA compliant
  • 8 parallel full-duplex channels
  • Compliant to IEEE802.3BJ
  • Pluggable/Direct Attach
  • Wire Gauge: 30 AWG
  • 2m Length
  • High-Speed Cable Assembly
  • RoHS compliant

Applications

  • 200G Ethernet

Product Description

This is an Arista Networks® CAB-O-8S-200G-2M compatible 200GBase-CU OSFP to 8xSFP28 direct attach cable that operates over passive copper with a maximum reach of 2.0m (6.6ft). It has been programmed, uniquely serialized, and data- traffic and application tested to ensure it is 100% compliant and functional. This direct attach cable is TAA (Trade Agreements Act) compliant, and is built to comply with MSA (Multi-Source Agreement) standards. We stand behind the quality of our products and proudly offer a limited lifetime warranty.

AddOn’s direct attach cables are RoHS compliant and lead free.

TAA refers to the Trade Agreements Act (19 U.S.C. & 2501-2581), which is intended to foster fair and open international trade. TAA requires that the U.S. Government may acquire only “U.S. – made or designated country end products.”

General Characteristics

Parameter Specification

Product Type Features
Cable Assembly Category| High Speed
Cable Assembly Type| Pluggable/Direct Attach
Connector End 1 Type| OSFP
Connector End 2 Type| SFP28 (8)
Assembly Color| Black
Cable Assembly Length| 2m (6.6ft)
Electrical Characteristics
Isolation Resistance| 100 Ω
Conductor Resistance| 2 Ω Max.
Voltage| 5V
Dimensions
Wire Gauge| 30 AWG
Body Features
Jacket Material| PVC

OSFP Electrical Pin-out Assignment

OSFP Electrical Pin-out Assignment

OSFP Pin Descriptions

Pin #| Symbol| Description| Logic| Direction| Plug Sequence
---|---|---|---|---|---
1| GND|  | Ground|  | 1
2| TX2p| Transmitter Data Non-Inverted| CML-I| Input from Host| 3
3| TX2n| Transmitter Data Inverted| CML-I| Input from Host| 3
4| GND|  | Ground|  | 1
5| TX4p| Transmitter Data Non-Inverted| CML-I| Input from Host| 3
6| TX4n| Transmitter Data Inverted| CML-I| Input from Host| 3
7| GND|  | Ground|  | 1
8| TX6p| Transmitter Data Non-Inverted| CML-I| Input from Host| 3
9| TX6n| Transmitter Data Inverted| CML-I| Input from Host| 3
10| GND|  | Ground|  | 1
11| TX8p| Transmitter Data Non-Inverted| CML-I| Input from Host| 3
12| TX8n| Transmitter Data Inverted| CML-I| Input from Host| 3
13| GND|  | Ground|  | 1
14| SCL| 2-wire Serial interface clock| LVCMOS-I/O| Bi-directional| 3
15| VCC| +3.3V Power|  | Power from Host| 2
16| VCC| +3.3V Power|  | Power from Host| 2
17| LPWn/PRSn| Low-Power Mode / Module Present| Multi-Level| Bi- directional| 3
18| GND|  | Ground|  | 1
19| RX7n| Receiver Data Inverted| CML-O| Output to Host| 3
20| RX7p| Receiver Data Non-Inverted| CML-O| Output to Host| 3
21| GND|  | Ground|  | 1
22| RX5n| Receiver Data Inverted| CML-O| Output to Host| 3
23| RX5p| Receiver Data Non-Inverted| CML-O| Output to Host| 3
24| GND|  | Ground|  | 1
25| RX3n| Receiver Data Inverted| CML-O| Output to Host| 3
26| RX3p| Receiver Data Non-Inverted| CML-O| Output to Host| 3
27| GND|  | Ground|  | 1
28| RX1n| Receiver Data Inverted| CML-O| Output to Host| 3
29| RX1p| Receiver Data Non-Inverted| CML-O| Output to Host| 3
30| GND|  | Ground|  | 1
31| GND|  | Ground|  | 1
32| RX2p| Receiver Data Non-Inverted| CML-O| Output to Host| 3
33| RX2n| Receiver Data Inverted| CML-O| Output to Host| 3
34| GND|  | Ground|  | 1
35| RX4p| Receiver Data Non-Inverted| CML-O| Output to Host| 3
36| RX4n| Receiver Data Inverted| CML-O| Output to Host| 3
37| GND|  | Ground|  | 1
38| RX6p| Receiver Data Non-Inverted| CML-O| Output to Host| 3
39| RX6n| Receiver Data Inverted| CML-O| Output to Host| 3
40| GND|  | Ground|  | 1
41| RX8p| Receiver Data Non-Inverted| CML-O| Output to Host| 3
42| RX8n| Receiver Data Inverted| CML-O| Output to Host| 3
43| GND|  | Ground|  | 1
44| INT/RSTn| Module Interrupt / Module Reset| Multi-Level| Bi- directional| 3
45| VCC| +3.3V Power|  | Power from Host| 2
46| VCC| +3.3V Power|  | Power from Host| 2
47| SDA| 2-wire Serial interface data| LVCMOS-I/O| Bi-directional| 3
48| GND|  | Ground|  | 1
49| TX7n| Transmitter Data Inverted| CML-I| Input from Host| 3
50| TX7p| Transmitter Data Non-Inverted| CML-I| Input from Host| 3
51| GND|  | Ground|  | 1
52| TX5n| Transmitter Data Inverted| CML-I| Input from Host| 3
53| TX5p| Transmitter Data Non-Inverted| CML-I| Input from Host| 3
54| GND|  | Ground|  | 1
55| TX3n| Transmitter Data Inverted| CML-I| Input from Host| 3
56| TX3p| Transmitter Data Non-Inverted| CML-I| Input from Host| 3
57| GND| | Ground|  | 1
58| TX1n| Transmitter Data Inverted| CML-I| Input from Host| 3
59| TX1p| Transmitter Data Non-Inverted| CML-I| Input from Host| 3
60| GND|  | Ground|  | 1

SFP28 Electrical Pin-out Assignment

SFP28 Electrical Pin-out Assignment

SFP28 Pin Descriptions

Pin Logic Symbol Name/Descriptions Ref.
1   VeeT Module Transmitter Ground 1
2 LVTTL-O Tx_Fault Transmitter Fault 2
3 LVTTL-I Tx_Disable Transmitter Disable 3
4 LVTTL-I/O SDA MOD-DEF2 2-wire serial interface data line 4
5 LVTTL-I/O SCL MOD-DEF1 2-wire serial interface clock line 4
6   Mod_Abs Module Absent 5
7 LVTTL-I RS0 Rate Select Zero
8 LVTTL- O Rx_LOS Module Receiver Loss of Signal 2
9 LVTTL-I RS1 Rate Select One
10   VeeR Module Receiver Ground 1
11   VeeR Module Receiver Ground 1
12 CML-O RD- Receiver Inverted Data Output
13 CML-O RD+ Receiver Non-Inverted Data Output
14   VeeR Module Receiver Ground 1
15   VccR Module Receiver 3.3V Supply
16   VccT Module Transmitter 3.3V Supply
17   VeeT Module Transmitter Ground 1
18 CML-I TD+ Transmitter Non-Inverted Data Input
19 CML-I TD- Transmitter Inverted Data Input
20   VeeT Module Transmitter Ground 1

Notes:

  1. The module signal grounds, VeeR and VeeT, shall be isolated from the module case.

  2. This is an open collector/drain output and shall be pulled up with 4.7-10k to Vcc_Host on the host board.
    Pull ups can be connected to multiple power supplies, however the host board design shall ensure that no module has voltage exceeding module VccT/R + 0.5 V.

  3. This is an open collector/drain input and shall be pulled up with 4.7-10k to VccT in the module.

  4. See 2-wire electrical specification.

  5. This shall be pulled up with 4.7-10k to Vcc_Host on the host board.

Wiring Table

Wiring Table

Wire Gauge and Bend Radius

Wire Gauge and Bend Radius

OSFP (Vertical Direction)

CABLE GUAGE| DIAMETER “Dl”| DIAMETER “D2”| MIN.BEND RADIUS “R”| MIN.BEND SPACE “L1”
30AWG| 4.1MM| 12.3MM|  21MM| 118MM

Wire Gauge and Bend Radius

OSFP ( Horizontal Direction)

CABLE GUAGE| DIAMETER “Dl”| DIAMETER “D2”| MIN.BEND RADIUS “R1”| MIN.BEND SPACE “Lif
30AWG| 4.1MM| 12.3MM| 21MM| 118MM

Wire Gauge and Bend Radius

SFP28 ( Horizontal Direction)

CABLE GUAGE| DIAMETER “D2”| RADIUS MIN,BEND “R2′| MIN.BEND SPACE “L2”
30AWG| 4,1MM| 20MM| 40MM

Wire Gauge and Bend Radius

SFP28 (Vertical Direction)

CABLE GUAGE| DIAMETER “D2”| RADIUS MIN.BEND “R2,’| SPACE MIN.BEND “L2”
30AWG| 4.1MM| 20MM| 40MM

Mechanical Specifications

Mechanical Specifications

Item Name Description Quantity Unit
1 Cable SFP28 2P PVC A/R mm
2 Plug 1 OSFP Plug, Reference OSFP MSA 3.0 1 PCS
3 Dust Cap 1 OSFP Dust Cap Black 1 PCS
4 Pull Tab 1 Stainless Steel + TPV, White 1 PCS
5 HST Heat Shrink Tube, Black 1 PCS
6 Plug 2 SFP28 Plug 8 PCS
7 Dust Cap 2 SFP28 Dust Cap Blue 8 PCS
8 Pull Tab 2 SFP28 Latch PA66 Black 8 PCS
9 Label 1 15x35mm, White 8 PCS
10 Label 2 26x57mm, White 1 PCS

Mechanical Specifications

About AddOn Networks

In 1999, AddOn Networks entered the market with a single product. Our founders fulfilled a severe shortage for compatible, cost-effective optical transceivers that compete at the same performance levels as leading OEM manufacturers. Adhering to the idea of redefining service and product quality not previously had in the fiber optic networking industry, AddOn invested resources in solution design, production, fulfillment, and global support.

Combining one of the most extensive and stringent testing processes in the industry, an exceptional free tech support center, and a consistent roll-out of innovative technologies, AddOn has continually set industry standards of quality and reliability throughout its history.

Reliability is the cornerstone of any optical fiber network and is in engrained in AddOn’s DNA. It has played a key role in nurturing the long-term relationships developed over the years with customers. AddOn remains committed to exceeding industry standards with certifications from ranging from NEBS Level 3 to ISO 9001:2005 with every new development while maintaining the signature reliability of its products.

U.S. Headquarters
Email: [email protected]
Telephone: +1 877.292.1701
Fax: 949.266.9273

Europe Headquarters
Email: [email protected]
Telephone: +44 1285 842070

www.addonnetworks.com
Phone: 877.292.1701

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

addon User Manuals

Related Manuals