The Unisenza Digital Thermostat is an electronic device that allows you to control the temperature of your heating and cooling system.

Product Features

  • Switch ON/OFF
  • Select Mode – Comfort mode, Reduced/Eco mode, Manual mode
  • Change Set temperatures in Comfort, Eco and manual mode
  • External sensor (NTC 10 KOhm)
  • Wire ground terminal (NTC 10 KOhm)
  • Switch output (Live 230 Vac during request or Live 24 Vac during request)
  • Heating and Cooling terminal (Live 230 Vac: cooling or Live 24 Vac: cooling)
  • Night set back input (Live 230 Vac: reduced mode or Live 24 Vac: reduced mode)
  • Live input 230 Vac
  • Live input 24 Vac
  • Neutral input 230 Vac
  • Neutral input 24 Vac

Product Usage Instructions

To use the Unisenza Digital Thermostat, follow the instructions below:

  1. Wiring: Connect the wires to the appropriate terminals. Terminals include NTC, GND, SWL, CO, NSB, L, and N.
  2. Switch ON/OFF: Turn the thermostat ON/OFF.
  3. Select Mode: Press and hold for more than 5 seconds to select between Comfort mode, Reduced/Eco mode, and Manual mode.
  4. Change Set Temperatures: Use the blinking numbers 1, 2, 3, 4 to change set temperatures in Comfort, Eco, and Manual mode. Alternatively, you can use one tap or N, L, NSB, CO, SWL to change set temperatures.

Refer to the user manual for more detailed instructions and troubleshooting tips.

Switch ON/OFF

Select Mode

Comfort mode

Reduced/Eco mode

Manual mode

Change Set temperatures in Comfort, Eco and manual mode

MYSON-Unisenza -Digital--Thermosta-06

Wiring

Terminals 230 Vac version 24 Vac version

  1. NTC External sensor (NTC 10 KOhm)

  2. GND Wire ground terminal (NTC 10 KOhm)

    1. SWL: Switch output (Live 230 Vac during request)
      Switch output (Live 24 Vac during request)
  3. CO
    Heating and Cooling terminal (Live 230 Vac: cooling)
    Heating and Cooling terminal (Live 24 Vac: cooling)

  4. NSB
    Night set back input (Live 230 Vac: reduced mode)
    Night set back input (Live 24 Vac: reduced mode)

  5. L: Live input 230 Vac Live input 24 Vac

  6. N: Neutral input 230 Vac Neutral input 24 Vac