VORTICE VORT HRW 60 MONO EVO HCS Wi-Fi Heat Recovery Unit Instructions

June 16, 2024
VORTICE

VORTICE VORT HRW 60 MONO EVO HCS Wi-Fi Heat Recovery Unit

Product Information

  • Specifications
    • Model: Vort HRW 60 Mono Evo HCS
    • WiFi: Yes
    • Product Code: 5.671.084.096
    • Date: 21/02/2023
  • Description and Usage
    • The Vort HRW 60 Mono Evo HCS is a high-quality ventilation system that ensures optimal airflow in various settings.
    • It is designed for both residential and commercial use.
  • Safety
    • Before using the product, it is essential to read and understand the safety instructions provided in the user manual.
    • Failure to follow these instructions may result in damage to property or personal injury.
    • Always keep the instruction booklet in a safe place for future reference.
  • Structure and Equipment
    • The Vort HRW 60 Mono Evo HCS features a durable body with a pre-installed terminal block, a front grille, and a polycarbonate aesthetic panel.
    • The panel has been tested according to UNI EN ISO 11925-2:2010 standards and achieved Class E for fire reaction (according to EN 13501-1).
  • Installation
    • Mounting the Grille from the Inside:
    • Prepare the two holes for power cables and signal cables inside the dashed area as shown in the figure.
    • Connect the power cables and signal cables to the terminal block.
    • Mounting the Grille from the Outside:
    • Prepare the two holes for power cables and signal cables inside the dashed area as shown in the figure.
    • Connect the power cables and signal cables to the terminal block.
  • Usage
    • To use the appliance, ensure that the closing disc is in the open position by rotating the lever to position 2 (see Figure 17).
  • FAQ
    • Q: What should I do if I encounter any issues with the product?
    • A: If you encounter any issues with the product, please contact an authorized VORTICE Technical Service Center immediately for assistance. They will provide guidance and, if necessary, arrange for repairs using genuine VORTICE spare parts.
    • Q: Can I perform external cleaning maintenance on the appliance?
    • A: Yes, you can perform external cleaning maintenance on the appliance. However, ensure that the appliance is properly turned off and disconnected from the power supply before cleaning. Use a suitable cleaning method to ensure optimal airflow.
    • Q: What should I do if I don’t plan to use the appliance for an extended period?
    • A: If you don’t plan to use the appliance for a short or long period, it is recommended to follow the instructions provided in the user manual. This may include turning off the appliance and disconnecting it from the power supply.

Description and use

  • Vort HRW 60 Mono Evo HCS / Vort HRW 60 Mono Evo HCS WiFi (hereinafter “the device”) is a decentralized heat recovery ventilation system, which can be installed on perimeter walls between 283 and 700 mm in depth, hole diameter of 160mm (nominal).
  • The device has a maximum air flow rate of 60m3/h (17l/s) when in boost mode, a maximum absorbed power of 8W.
  • The device has a remote control and integral relative humidity, temperature and ambient light sensors.
  • The sensors allow automatic operation of the device (Auto HR%, Auto Comfort, Auto night functions. See the appropriate section of the manual.

General features:

  • 5 speeds corresponding to 5 airflows.
  • 1 input suitable for remote connection utilizing hard-wired cable compatible with external modules “VORTICE C TEMP” (temperature sensor) and “VORTICE C HCS” (humidity sensor) or equivalent. Cable length≤30m.
  • 1 direct output for fan control.
  • RS485 communication BUS to synchronize together pairs of devices.
  • Integrated WiFi module for synchronizing different units (Mesh network, WiFi models only)
  • Long-term timer (3/6/12 months) with daily increase for filter clogging control.
  • Insulation class: II.
  • Power supply: 220-240V ~ 50-60Hz.

Compliance

  • This appliance can be used by children no less than 8 years of age and by individuals with limited physical, sensory or mental capacities, or by inexperienced or untrained individuals, provided that they are supervised or have been instructed in safe use of the appliance and understand the associated risks. Children must not play with the appliance.
  • Cleaning and maintenance procedures that can be undertaken by the user must not be entrusted to children, unless under supervision.
  • These appliances are designed for use in residential and commercial properties.
  • The appliance must be installed by a professionally qualified electrician.
  • The electrical system to which the product is connected must comply with applicable regulations.
  • An omnipolar switch with a contact opening distance of 3 mm or higher should be provided for installation, enabling complete disconnection under overvoltage category III conditions.
  • Products equipped with single-phase wiring (M) engines ALWAYS require connection to 220-240V (or only 230V where required) single-phase lines. Any kind of modification shall be considered as product tampering and shall nullify the relative warranty.
  • Precautions must be taken to prevent gas coming from the gas flue pipe or from other fuel combustion units from entering the room.
  • Fans have been designed to be mounted on external walls.

Safety

Warning: this symbol indicates that care must be taken to avoid injury to the user.• Follow the safety instructions to prevent any harm to the user.

  • Do not use this appliance for purposes other than those described in this manual.
  • Having removed the appliance from its packaging, make certain that it is intact and undamaged. If in doubt, consult a professional or contact an authorized VORTICE Service Centre.
  • Do not leave packaging within reach of children or individuals with disabilities.
  • Certain basic rules must always be observed when using any electrical appliance: never touch the appliance with wet hands; never touch the appliance when barefoot.
  • Do not operate the appliance in the presence of flammable substances or vapours, such as alcohol, insecticides, petrol, etc.
  • If the appliance is to be disconnected from the power supply and no longer used, store it out of reach of children and individuals with disabilities.

Caution: this symbol indicates that care must be taken to avoid damaging the appliance

  • Do not make modifications of any kind to this appliance.
  • The maintenance instructions must be followed to ensure the appliance does not suffer damage and/or excessive wear.
  • Do not expose this appliance to the elements (rain, sun, etc.).
  • Do not stand objects on the appliance.
  • The inside of the appliance must be cleaned only by a skilled professional.
  • Inspect the appliance periodically for visible defects. If the appliance is defective in any way, do not use it; contact a VORTICE-authorized Technical Support Centre without delay.
  • If the appliance does not function correctly or develops a fault, contact a VORTICE-authorized Technical Support
  • Centre without delay. Ensure that only genuine original VORTICE spares are used for any repairs.
  • Should the appliance be dropped or suffer a heavy impact, have it checked without delay by a VORTICE-authorized Technical Support Centre.
  • The appliance must be installed in such a way as to ensure that under normal operating conditions, no one can come into contact with any moving parts or live electrical components.
  • In the event of: dismantling the appliance with the appropriate tools, removing the heat exchanger for cleaning is recommended: every six months)or removing the motor module, the appliance must first be switched off and disconnected from the electrical power supply.
  • Connect the appliance to the electrical power supply/socket only if the rated power of the supply is compatible with the maximum rated power of the appliance. If not, contact a professional electrician without delay.
  • Turn off the appliance at the main switch: if the appliance does not function correctly, before cleaning the outside of the appliance, or if the appliance is not going to be used for any length of time.
  • The flow of extracted air must be clean (i.e. free of grease, soot, chemical and corrosive agents and explosive or flammable mixtures).
  • Keep the air intake and outlet ports of the appliance free of obstructions, to ensure optimum air flow.
  • Operating temperature range: -20 to 50°C.
  • Specifications for the power supply must correspond to the electrical data on plate A (fig.1).

Structure and equipment

The principal components of the device are (fig.2) The main components of the device are:

  • main body (1) already assembled which includes:
    • body with pre-assembled plug-in terminal block, front grille and aesthetic panel in polycarbonate (PC) tested according to standard UNI EN ISO 11925-2:2010 and resulted in class E for reaction to fire (according to the EN 13501-1 standard);
    • motor holder and push-button panel in ABS material;
    • 5-speed reversible EC fan;
    • Integrated electronic board;
    • closing device (disk) sealing the front panel to prevent temperature changes in the winter months and the entry of pollutants and odors from the outside;
    • washable internal filter with frame;
  • flange (2) wall mountable with pre-assembled terminal block;
  • terminal block cover with screw and cable gland (3);
  • PVC pipe for installation inside walls with thickness from 283 mm to 700 mm (optional);
  • storage type heat exchanger, made of ceramic material supplied with two expanded polyproylene (EPP) housings and it is complete with a central gasket to prevent air infiltration (4B);
  • outer rubber grille (5B), which can be mounted externally with plugs or inserted internally through the hole in the wall with no need for external scaffolding;
  • washable external filter with holder grids (x2) (6);
  • insect grid (7);
  • remote control (8).

Installation

Fig 3 ÷ 16

  • NOTE: before proceeding with the installation, remove the internal protective packaging in the appliance.
  • NOTE: before carrying out installation, remove the spacers inside the PVC installation pipe (provided as accessory) and cut the pipe according to the wall thickness.
  • It is mandatory to install the device within a perimeter wall with a thickness of at least 283 mm.

Use

  • To use the appliance, make sure the lever of the closing disk is in the open position, by rotating the lever to position 2 (fig.17).

DESCRIPTION OF THE UNIT COMMANDS

Warning (fig. 18):

  • The control panel is accessible by inserting the hand in the space between the cover and the front grille (1) or by lifting up the cover (2).

  • The device is controlled by means of on-board buttons (Fig. 19).

  • A: SPEED SELECTION KEY: 5 position selector (Night / Quiet / Performance / High performance / Boost). LED 1- LED 5: speed/air flow from min to max. Press the button sequentially to select the desired speed setting. The white LEDs from 1 to 5 will light up to indicate the speed from 1 to 5.

  • B: MODE KEY: three position selector. Press sequentially to cycle through the different operating modes: recovery, intake, extraction, and natural ventilation (intake and extraction LEDs switch on simultaneously).

The respective LEDs will light up steadily:

  • RECOVERY heat recovery (the system works as a heat recovery unit, with cyclic inversion of the direction of rotation).
  • INTAKE The system operates as a fan, supplying are to the room.
  • EXTRACTION the system works as a fan, with air extraction from the room.
  • NATURAL VENTILATION If the device is connected to one or more units via RS485 communication bus, (or Mesh network, WiFi models only), you can set the NATURAL VENTILATION mode: if set as an even unit the device will operate in extraction mode, if set as an odd unit the device will operate in intake mode, creating an air current in the environment.
  • Note 1: natural ventilation can be selected automatically via the external IR remote control (see fig. 23).
  • Note 2: The RS485 bus (or the WiFi module, WiFi models only), allows to balance of the air flow rates of intake and extracted air, provided that the total number of installed units is equal to an even number. For example, 4 units can be connected on the RS485 bus setting two units as “even” and two units as “odd”. In the case of an installation of an odd number of units, the air flow balancing will not occur.
  • Note 3: To see how to set the device as an even or an odd unit, refer to the section “parameter programming sequences”.
  • Note 4: The backlighting of the keys on the device remains active for one minute from the last press of any key.
  • Note 5:The backlighting of the keys on the remote control remains active for 15 seconds from the last press of any key.
  • C: FUNCTION KEY to activate or deactivate 3 different AUTO functions available and activate or deactivate the stand-by mode.

To activate or deactivate the standby mode:

  • If the device is switched on and the FUNCTION key is pressed (stand-by / on-off function), the fan stops and the LEDs of the SPEED column turn off.
  • If the appliance is off and you press the FUNCTION button, the appliance starts at the speed and mode previously set.

The available functions are:

  • Auto night
    • The ambient light sensor detects the presence or absence of ambient light and, depending on whether the measurement is higher or lower than the threshold (factory set and non-adjustable).
    • When below the set light level the unit goes to night speed (minimum) and prevents the selection of a higher speed setting.
  • • Auto HR%
    • In case of the presence of humidity beyond the alarm threshold (60%, 75% or 90% – the default value is 75%), the device automatically selects extraction mode at Boost (maximum) speed.
  • Auto comfort
    • In heat recovery mode, the period that determines the inversion of rotation of the fans is fixed based on the temperature of the air introduced into the room: if too cold, the cycle time is reduced.

To select a function (fig. 20):

  1. Press the FUNCTION button for more than 2 seconds.
  2. press the SPEED button to select one of the three LEDs LED1 AUTONIGHT LED2 AUTO HUMIDITY (HR%) LED3 AUTO COMFORT
  3. press the MODE button to enable the function -> the chosen LED in the mode column blinks.
  4. To save the settings, press the FUNCTION button for more than 2 seconds. All SPEED LEDs blink 4 TIMES to indicate correct storage.
  5. to CANCEL and exit the setting procedure, press the FUNCTION key once. All SPEED LEDs blink ONLY ONCE WITHOUT SAVING any changes made.
  6. to CHECK which function is assigned to the appliance, press the FUNCTION button for more than 2 seconds: the LED corresponding to the set function blinks for about 20 seconds, then all the speed LEDs flash and the device returns to standard display.
    • Note: The user can enable all three functions simultaneously.

To disable a function (fig. 21):

  1. press the FUNCTION button for more than 2 seconds.
  2. press the SPEED button to select one of the three LEDs LED1 AUTONIGHT LED2 AUTO HUMIDITY (HR%) LED3 AUTO COMFORT
  3. press the MODE button to disable the function.
  4. to SAVE the settings, press the FUNCTION button for more than 2 seconds. All SPEED LEDs blink 4 TIMES to indicate correct storage.
  5. to CANCEL and exit the setting procedure, press the FUNCTION key once. All SPEED LEDs blink ONLY ONCE WITHOUT SAVING any changes made.
  6. to CHECK which function is assigned to the appliance, press the FUNCTION button for more than 2 seconds: : the LED corresponding to the set function blinks for about 20 seconds, then all the speed LEDs flash and the device returns to standard display.

D: FILTER LED
One led (D – fig. 19) shows the status of the filters:

  • LED OFF: filters are clean
  • LED ON: filters to be cleaned or replaced (for each day of operation, a counter in the memory is increased and when the maximum preset time is reached (90/180/365 days), the signalling LED lights up).

Refer to section “Maintenance and cleaning”.

TURNING THE DEVICE OFF

  • To set the device into standby (non-operating) mode press the FUNCTION key, and the SPEED LEDs will turn off.
  • To stop unwanted drafts turn the shutter to the closed position (2) (fig. 22)

Parameter programming

To enter programming mode:

  • Press simultaneously the SPEED – MODE – FUNCTION buttons.
  • LED 5 turns on white.
  • Press the buttons in the following sequence: SPEED – SPEED – MODE – FUNCTION – FUNCTION – MODE.

To set the relative humidity threshold (HR%):

  • Press the SPEED button.
  • The current threshold setting is displayed by the LED’s. LED 1 60%, LED 2 75% & LED 3 90% (default setting 75%).
  • Press the SPEED button to modify the threshold value.
  • Press the FUNCTION button to confirm.
  • All the speed LEDs from 1 to 5 will blink briefly to indicate that the value has been stored and the device will return to normal operation.
  • If you do not press the FUNCTION button within 20 sec, the device will return to normal operation without storing any changes.

To select cycle time:

  • Press the MODE button.
  • The current time setting is displayed by the LED’s. LED 1 50sec, LED 2 60sec & LED 3 90sec (default setting 60sec).
  • Press the SPEED button to change the value.
  • Press the FUNCTION button to confirm.
  • All the speed LEDs from 1 to 5 will flash briefly to indicate successful storage and the device will return to normal operation.
  • If the FUNCTION button is not pressed within 20 sec, the device will return to normal operation without memorizing.
    • NOTE: Cycle time programming can only be carried out on the unit set as master.

To select the clogged filter alarm interval:

  • Press the FUNCTION button.
  • The current time interval is displayed by the LED’s. LED 1 90, LED 2 180 & LED 3 365 days.
  • Press the SPEED button to modify the value.
  • Press the FUNCTION button to confirm.
  • All the speed LEDs from 1 to 5 will blink briefly to indicate that the storage has taken place and the equipment will return to normal operation.
  • If the FUNCTION key is not pressed within 20 sec, the device will return to normal operation without memorizing.

To reset the clogged filter counter:

  • Press the SPEED – MODE – FUNCTION buttons simultaneously.
  • Press the buttons in the following sequence: MODE – MODE – SPEED – SPEED – MODE – MODE.
  • Press the Function key within 20 sec.
  • All the speed LEDs from 1 to 5 will blink briefly to indicate that the reset has taken place and the device will return to normal operation.
  • If the FUNCTION button is not pressed within 20 sec, the device will return to normal operation without having reset the filter timer.
  • Note: for regular operation between multiple devices, it is necessary to set the type of unit (Master / Slave and Even / Odd)

To set the device as “RS485 network master”, or Mesh Network master (WiFi models only):

  • Press simultaneously the SPEED – MODE – FUNCTION buttons.
  • Press in sequence the following buttons: MODE – MODE – SPEED – SPEED – FUNCTION – FUNCTION.
  • Press the MODE button within 20 sec.
  • All speed LEDs from 1 to 5 will blink briefly to indicate that the device has been set as the master unit.
  • If you do not press the MODE button within 20 sec, the device will return to normal operation without making any changes to the settings.

To set the device as “RS485 network slave”, or Mesh Network slave (WiFi models only):

  • Press simultaneously the SPEED – MODE – FUNCTION buttons.
  • Press in sequence the following buttons: MODE – MODE – SPEED – SPEED – FUNCTION – FUNCTION.
  • Press the SPEED button within 20 sec.
  • All speed LEDs from 1 to 5 will blink briefly to indicate that the device has been set as the Slave.
  • If the SPEED button is not pressed within 20 sec, the device will return to normal operation without making any changes to the settings.

To set the device as “Even Unit”:

  • Press simultaneously the buttons: SPEED – MODE – FUNCTION
  • Press in sequence the buttons: SPEED – SPEED – FUNCTION – FUNCTION – MODE – MODE.
  • Press the SPEED button within 20 sec.
  • All speed LEDs from 1 to 5 will blink briefly to indicate that the device has been set as an even-numbered unit.
  • If the SPEED button is not pressed within 20 sec, the device will return to normal operation without making any changes to the settings.

To set the device as an “Odd Unit”:

  • Press simultaneously the SPEED – MODE – FUNCTION buttons.
  • Press in sequence the buttons SPEED – SPEED – FUNCTION – FUNCTION – MODE – MODE.
  • Press the FUNCTION key within 20 sec.
  • All speed LEDs from 1 to 5 will blink briefly to indicate that the device has been set as an odd-numbered unit.
  • If the Function button is not pressed within 20 sec, the device will return to normal operation without making any changes to the settings.

Parameters programming Mesh network (WiFi models only)

  • The WiFi module creates a mesh wifi network to synchronize the units.
  • The mesh network is identified by a particular SSID (Service Set Identifier), which will be generic by default during installation and will become unique for each particular network once installation is completed.
  • To set the SSID (Service Set Identifier) of the WiFi mesh network
  • From the factory setting the machines are set as SLAVE, it is therefore necessary to set a unit as MASTER by pressing the speed – mode – function buttons simultaneously by pressing the MODE – MODE – SPEED – SPEED – FUNCTION – FUNCTION buttons in sequence and then the MODE button .
  • Press simultaneously the SPEED – MODE – FUNCTION buttons on the MASTER device.
  • Press the MODE – MODE – SPEED – SPEED – MODE – MODE buttons in sequence.
  • Press the SPEED button within 20 seconds
  • All speed LEDs from 1 through 5 will briefly blink to indicate that SSID = VOR_XXXXXXXX has been set on

EACH SINGLE UNIT IN THE NETWORK

  • If the SPEED button is not pressed within 20 seconds, all SPEED LEDs from 1 to 5 will light up for 1 second without blinking to indicate that the appliance will return to normal operation without resetting the network SSID.
  • Note: The change from the default network SSID “VORTICE_HRW” to a unique network SSID is mandatory in order to prevent interference between different devices belonging to different networks (for example, in the case of two independent flats separated by a wall, etc.).
  • Note: you must have a smartphone or network detection device handy to view the names of theassigned networks.

To set the SSID in the case of two installed networks (for example two networks on two different floors) follow these steps:

  1. Switch off the units that are not part of the network on which you want to operate (for example those on the upper floor if you want to set the network on the lower floor) them being assigned to the incorrect SSID.
  2. Then, from the MASTER unit, assign the unique network identifier (SSID) by pressing the MODE – MODE – SPEED – SPEED – MODE – MODE buttons in sequence and then the SPEED button.
  3. To set up another network (the upper floor in the example), you do not need to turn off the units of the other set up network as they already have a unique SSID.

To reset the mesh WiFi network (global / all network units) SSID:

  • Press simultaneously the SPEED – MODE – FUNCTION buttons.
  • Press the MODE – SPEED – FUNCTION – MODE – SPEED- FUNCTION buttons in sequence.
  • Press the MODE button within 20 second
  • All the speed LEDs from 1 to 5 will flash briefly to indicate execution of the command:
    • Reset the SSID = VORTICE_HRW (default) FOR ALL UNITS ON THE NETWORK.
  • If the MODE button is not pressed within 20 seconds, all speed LEDs 1 to 5 will light up for 1 second without flashing, indicating that the machine will return to normal operation without resetting the network SSID.

To reset the WiFi mesh network (local / single unit on the network) SSID:

  • Press simultaneously the SPEED – MODE – FUNCTION buttons on the SLAVE device.
  • Press the MODE – MODE – SPEED – SPEED – MODE – MODE buttons in sequence.
  • Press the SPEED button within 20 seconds
  • All the SPEED LEDs from 1 to 5 will blink briefly to indicate that SSID = VORTICE_HRW (default) has been reset FOR THE SINGLE UNIT ONLY.
  • If the SPEED button is not pressed within 20 seconds, all SPEED LEDs from 1 to 5 will light up for 1 second without blinking to indicate that the appliance will return to normal operation without resetting the network SSID.

MAC Address and SSID

  • The MAC Address is assigned by the manufacturer of the WiFi module itself and it is unique.
  • The last 4 hexadecimal digits of the MAC Address (UAA = Unique Address Assignment) of the master unit are used to generate the unique SSID of the network:
  • VOR_XXXXXXXX (e.g. VOR_34F5E4E7)
  • Each digit consists of two hex characters ranging from 0 to 255 (0x00-0xFF).
  • The default SSID is instead VORTICE_HRW with default password = “12345678” which cannot be changed.

Adding one or more new units to an existing mesh network

  1. Go into programming mode by pressing simultaneously the SPEED – MODE – FUNCTION buttons.
  2. From any unit of this network, reset all the network identifiers (SSID) of each unit in the existing network by pressing the MODE – SPEED – FUNCTION – MODE – SPEED – FUNCTION buttons in sequence and then the MODE button.
  3. Or, if there are units with unknown SSIDs or which are different from the network SSID, set each unit to SLAVE mode by pressing the MODE – MODE – SPEED – SPEED – FUNCTION – FUNCTION buttons in sequence and then the SPEED button. Afterwards set the default identification (SSID) on each unit by pressing in sequence the buttons MODE – MODE – SPEED – SPEED – MODE – MODE and then the SPEED button.
  4. If a MASTER unit has not yet been defined, a network unit must be set as MASTER by pressing the MODE -MODE – SPEED – SPEED – FUNCTION – FUNCTION buttons in sequence and then the MODE key..
  5. Finally assign the unique network identification (SSID) from the MASTER unit by pressing the MODE – MODE – SPEED – SPEED – MODE – MODE buttons in sequence and then the SPEED button.

Remote I/O control

The connected device can be remotely controlled via clean contacts on remote input 1. If the remote input is active, the keyboard on the machine is disabled.

  • Remote input # 1:
    • With input contact 1 closed, all the connected fans work in extraction at maximum speed.
    • If 20 seconds since the last key press has not elapsed:
  • The white EXTRACTION LED lights up.
  • The white 1,2,3,4,5 LEDs light up.

Remote control

HCS models are equipped with a remote control with LCD. By default the recovery function, the auto comfort, auto HR% and tonight modes are active. The humidity threshold is set at the maximum value (90%) and the speed is set to the maximum to obtain the maximum air flow rate (5 fans displayed). The remote control transmits its default state to the device and consequently updates the state of the appliance. If the state of the device does not synchronize with the state of the remote control, point the remote control towards the device and press a button on the remote control to activate the synchronization. After inserting the batteries, the remote control is active. After pressing the ON / OFF button, the display looks like in figure 24:

Keys description:

  • ON/OFF FUNTION
  • Press the ON/OFF key to start the device or to select the STANDBY mode.

FAN SPEED FUNCTION

  • Fan speed selection is always available. Press the Fan key to select fan speed (MINIMUM
  • \LOW\MED\HIGH\BOOST). Fan speed mode will cycle as below:

“AUTO NIGHT” FUNCTION

NIGHT AUTO function is always available. Press the NIGHT AUTO button at any time to toggle the NIGHT AUTO function on and off.

“TIMED BOOST” FUNCTION

Press the TIMED BOOST button at any time to toggle the TIMED BOOST function ON and OFF.

  • NOTE: If the TIMED BOOST function is ON, the TIMED BOOST icon remains active for 30 minutes and then switches off. If the TIMED BOOST is ON and then the TIMED BOOST key is pushed, then the TIMED BOOST icon will immediately switch off.
  • NOTE: If the TIMED BOOST function is ON, then the five fan speed icon must be ON:

“HEAT RECOVERY” MODE
Press the “heat recovery button” at any time to select HEAT RECOVERY mode.

  • NOTE: if the HEAT RECOVERY button is pushed, then the SUPPLY icon , EXTRACT icon ,
  • THE NATURAL VENTILATION icon will switch off.

“AUTO COMFORT” FUNCTION

  • Press the AUTO COMFORT button at any time to toggle the AUTO COMFORT function ON and OFF.

HUMIDITY THRESHOLD

Press the HUMIDITY THRESHOLD button to select the HUMIDITY THRESHOLD value (OFF/ LOW(60%)/MED(75%)/HIGH(90%). HUMIDITY THRESHOLD value will cycle as in the following table:

“SUPPLY” MODE

Press the “supply” button at any time to select SUPPLY mode.

  • NOTE: if the SUPPLY button is pushed, then the HEAT RECOVERY icon , EXTRACTION icon and NATURAL VENTILATION icon will switch off.

“EXTRACTION” mode

  • Press the “extraction” button to select this mode.

  • NOTE: if the EXTRACTION button is pushed, ,, then the HEAT RECOVERY icon , SUPPLY icon and NATURAL VENTILATION icon will switch off.

“NATURAL VENTILATION” mode

  • Press the NATURAL VENTILATION button to select this mode.
  • NOTE: if the NATURAL VENTILATION button is pushed, then the HEAT RECOVERY icon , SUPPLY icon and EXTRACTION will switch off

“Low battery indication” function

  • When the remote control has been used for a long time and there is no enough power left, the remote control will show “low battery indication” on the LCD, it shows the user need to replace a new battery.
  • It will blink all the time till the battery has been replaced.

“Backlight” function

  • When using the remote control, the LEDs backlight is on. If the remote control has not been used for 10 seconds, the backlight function is turned off for energy saving.

“Reset” function

  • A small hole in the back of the remote control works as reset function.

Technical data

Nominal duct diameter (mm) 160
Airflow max (l/s) Night
Quiet 6,94
Performance 9,72
High Performance 12,5
Boost 16,67
Pressure max (Pa) Night
Quiet 39
Performance 62
High Performance 100
Boost 120
Sound power level Lw [dB(A)] Night
Quiet 45
Performance 52
High Performance 57
Boost 62
Sound pressure level Lp [dB (A)] 3m Night
Quiet 27
Performance 34
High Performance 39
Boost 45

Maintanance and cleaning

  • Before starting any maintenance or cleaning operation set the device to standby mode (LEDs in SPEED column turn off) and wait for the fan to stop.

Filters cleaning

  • The maintenance time for filters can be set to 90, 180 or 365 days (see specific section in the “programming sequence”).
  • Cleaning /replacement of internal filter (fig. 25): Remove the closing disk (1), remove the filter (2), wash or replace it and reposition it in its seat with the filter frame; re-insert the closing disk.
  • Cleaning /replacement of external filter (fig. 26: follow the steps from 1 to 6 and repeat them in the reverse order once the filter has been cleaned or removed.
  • On every model it is mandatory to reset the saturated filter situation by following the procedure described in the section “parameters programming sequence”, before returning to the normal functioning of the device.
  • N.B. Failure to clean or replace filters causes problems for system efficiency, including:
  • Increase in pressure losses in the air circuit and reduction of air flow;
  • Consequent decrease in machine yield and worsening of comfort in the environment.

Disposal

  • This product complies with Directive 2012/19/EU on the management of waste electrical and electronic equipment (WEEE).
  • The crossed-out wheeled bin symbol on the appliance indicates that, at the end of its life, the product should not be discarded together with household waste but must be taken to a separate collection point for electrical and electronic equipment.
  • This will avoid negative effects on the environment and health and will encourage correct treatment, disposal and recycling of the materials from which the product is made.
  • Contact the municipal authority for the location of this type of facility.
  • Alternatively, the distributor is obliged to take back the appliance to be disposed of free of charge in exchange for the purchase of an equivalent appliance.

VORTICE S.p.A. reserves the right to make improvements to products at any time and without prior notice.

CONTACT

VORTICE GROUP COMPANIES

GUARANTEE

  • A. CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE
    • DATE OF WORK
    • STAMP OF TECHNICAL ASSISTANCE CENTRE
  • B. CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE
    • DATE OF WORK
    • STAMP OF TECHNICAL ASSISTANCE CENTRE
  • C. CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE
    • DATE OF WORK
    • STAMP OF TECHNICAL ASSISTANCE CENTRE
  • D. CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE
    • DATE OF WORK
    • STAMP OF TECHNICAL ASSISTANCE CENTRE

UK AND IRELAND CONDITIONS OF WARRANTY

  • This guarantee is offered as an extra benefit and does not affect your legal rights. All electrical appliances produced by VORTICE SPA are guaranteed by the Company for 2  years against faulty material or workmanship.
  • If any part is found to be defective in this way within the first twenty-four months from the date of purchase or hire purchase agreement, we, or our authorised service agents, will replace or at our option repair that part without any charge for materials or labour or transportation, provided that the appliance has been used only per the instructions provided with each appliance and has been not connected to an unsuitable electricity supply, or subjected to misuse, neglect or damage or modified or repaired by any person not authorised by us.
  • The correct electricity supply voltage is shown on the rating plate attached to the appliance.
  • This guarantee is normally available only to the original purchaser of the appliance, but VORTICE will consider written applications for transfer. Should any defect arise in any Vortice product and a claim under guarantee become necessary, the appliance should be carefully packed and returned to your approved Vortice stocklist.
  • This portion of the guarantee should be attached to the appliance.

UK-IRELAND

  • Send the guarantee in a sealed envelope to:
    • Vortice Limited
    • Beeches House
    • Eastern Avenue
    • Burton on Trent
    • DE13 0BB United Kingdom
    • I authorize VORTICE LTD.
    • to include my details within their database, which they use, via a third party for the despatch of advertising material, at any time, by the regulations in force within my country. I can have access to my details and can request changes, or prohibit the usage of my details. This will be done by addressing my request directly to:
    • Vortice Limited Beeches House Eastern Avenue  Burton on TrentDE13 0BB United Kingdom.
    • I do not authorize (please tick if required)

TO BE RETAINED A CONSERVER

This warranty must be attached to the appliance should it need to be returned for servicing. N.B. The guarantee is only valid if all details are completed correctly.

  • Stamp of supplier
  • Mailing date –
    • CONF.
    • COLL.

Stamp of supplier

TO SEND (within 8 days from the date of purchase)

  • CUSTOMER DATA
  • name _____
  •  surname _____
  • via ____
  • postcode __
  • town ____

I have read and understood the terms and conditions of this guarantee and I authorize the processing of my details (see overleaf).

Signature

  • Mailing date
  • Cod. 5.671.084.096 21/02/2023

Read the instructions contained in this booklet carefully before using the appliance. VORTICE cannot assume any responsibility for damage to property or personal injury resulting from failure to abide by the instructions given in this booklet. Following these instructions will ensure a long service life and overall electrical and mechanical reliability. Keep this instruction booklet in a safe place.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VORTICE User Manuals

Related Manuals