VORTICE MP 254 T Helical Industrial Ventilation Instruction Manual

June 1, 2024
VORTICE

VORTICE-logo

VORTICE MP 254 T Helical Industrial Ventilation

VORTICE-MP-254 T-Helical-Industrial-Ventilation-
product

Product Information

Specifications

  • Product Name: VORTICEL MP
  • Product Code: 5.671.084.431
  • Release Date: 02/15/2024

Product Usage Instructions

Installation and Connection

  • Before installing and connecting the product, carefully read the instructions provided in the manual.

Safety Instructions

  • Follow all safety instructions to prevent damage to property or personal injury. Proper installation and connection ensure durability and reliability.

Maintenance

  • Regular maintenance is essential for long service life and overall electrical and mechanical reliability.

Accessories

  • The product comes with accessories that are detailed in the manual.

Typical Applications

  • The product is suitable for various typical applications as specified in the manual.

Description and Preparation

  • Details about the product description and preparation steps are provided in the manual.

Electrical Connections

  • Ensure proper electrical connections following the guidelines in the manual.

Main Features

  • Understand and utilize all main features of the product as described in the manual for optimal performance.

Additional Guidelines

  • Refer to the manual for any additional guidelines or specific instructions related to the product.

FAQs

Q: How often should I perform maintenance on the VORTICEL MP?

A: Regular maintenance is recommended to ensure long service life and reliability. Refer to the manual for specific maintenance schedules.

Q: Can I install the VORTICEL MP myself?

A: It is recommended to follow the installation instructions provided in the manual carefully. If unsure, consider seeking professional help for installation.

  • Read these instructions carefully before installing and connecting the appliance. Vortice cannot assume any responsibility for damage to property or personal injury resulting from failure to follow the instructions given in this booklet. Following these instructions will ensure long service life and overall electrical and mechanical reliability. Keep this instruction booklet in a safe place.
  • This symbol indicates that the operation must be carried out by a suitably qualified person.

TYPICAL APPLICATIONS

VORTICE-MP-254 T-Helical-Industrial-Ventilation-fig-1 VORTICE-MP-254 T-Helical-Industrial-Ventilation-
fig-2

DESCRIPTION AND OPERATION

  • The product you have purchased is a medium-pressure, industrial axial fan for air extraction into a ventilation duct or directly to the outside.
  • It is designed for installation in ventilation ducts or for extraction through filters in applications where load loss has been overcome. It must not be used to extract dusty air or acidic or corrosive fumes (fig. 1).

WARNING – CAUTION

  • Warning: this symbol indicates precautions that must be taken to avoid injury
  • Do not use this appliance for functions other than those described in this booklet.
  • After removing the appliance from its packaging, ensure that it is complete and undamaged. If in doubt contact a professionally qualified electrician or Vortice*. Do not leave packaging within the reach of children or infirm persons.
  • If you decide to stop using the appliance, switch it off and disconnect it from the power supply.
  • Do not use this appliance in potentially explosive or flammable atmospheres or to extract acidic or corrosive fumes (fig. 1).
  • If the appliance is installed at a height of less than  2.5 meters from the floor, it is obligatory to install protections for moving parts, in the form of the safety mesh frame and gravity shutter (fig. 4-5).
  • If the selected product exceeds 70 dB(A), adequate noise damping must be fitted when it is installed, or suitable personal protective equipment used.
  • Model Lp dB(A) (3m)
    • MP 302 M – T 75
    • MP 504 T 74
    • MP 604 T 79.5
  • Caution: this symbol indicates precautions that must be taken to avoid damaging the appliance.
  • Do not make modifications of any kind to this appliance.
  • Regularly inspect the appliance for visible defects.
  • If any faults are found, do not operate the appliance; contact Vortice* immediately.
  • If the appliance does not function correctly or develops a fault, contact Vortice* immediately.
  • Ensure that only genuine original Vortice spares are used for any repairs.
  • Should the appliance be dropped or suffer a heavy blow, have it checked immediately by Vortice*.
  • This appliance must only be installed and serviced, externally or internally, by professionally qualified personnel.
  • Switch off the appliance at the installation’s main switch: a) if the appliance does not function correctly; b) before cleaning the inside or outside of the appliance, c) if the appliance is not to be used for any length of time.
  • Ensure that the electrical system to which the appliance is connected complies with applicable standards.
  • Specifications for the power supply must correspond to those on the appliance’s data plate.
  • The circuit in which the appliance is installed must have an overload protection device calibrated to suit the nominal current shown on the appliance’s data plate.
  • This appliance must be connected to an efficient earthing system in compliance with applicable safety standards. If in doubt, ask a qualified electrician to check your system.
  • The electrical power supply/socket to which the appliance is to be connected must be able to provide the maximum electrical power required by the appliance. If it cannot do so, arrange for a qualified electrician to make the necessary modifications.
  • When installing the appliance, fit a multi-pole thermomagnetic cutout, with a contact gap of at least 3 mm.
  • If the appliance is installed outdoors, ensure that adequate weather protection is provided.
  • Where the fan is installed at a height below 2.3 m, including where there is a shutter installed, protect with a safety grate.
  • Fan for tropical climates (T).
  • To ensure the correct functioning of this appliance, you must ensure that there is a sufficient air supply to the room. If any unsealed fuel-burning appliances (e.g. boilers, gas stoves, etc.) are installed in the same room, make sure that the air supply is sufficient for this appliance and ensure correct combustion in the other appliance too.
  • This appliance must not be used to switch on and off boilers, heaters, etc., nor must it discharge air into the fume flues of such appliances.
  • Do not cover the appliance’s intake and outlet.
  • Only fit the specified accessories over the intake and outlet.
  • Make sure that the room is adequately ventilated to ensure proper air circulation.
  • Do not allow dust to build up on the motor. This can prevent correct cooling. Regular maintenance is essential for correct functioning and to achieve the declared levels of performance.
  • Follow the instructions in the figures to perform the necessary mechanical maintenance.
  • N.B. Do not submerge the electric motor in water or any other liquid.

SOUND EMISSIONS

MODEL EMISII SONORE Lp dB(A) 3 m

MP 302 M 75
MP 304 M 59
MP 354 M 64
MP 404 M 66
MP 252 M 70
MP 254 M 53
MP 302 T 75
MP 304 T 59

MODEL EMISII SONORE Lp dB(A) 3 m

MP 354 T 64
MP 404 T 66
MP 506 T 74
MP 454 T 66,5
MP 504 T 74
MP 254 T 53
MP 606 T 68,5
MP 604 T 79,5

INSTALLATION

Specifications for the power supply must correspond to the electrical data on data plate A.VORTICE-MP-254 T-Helical-Industrial-Ventilation-
fig-5

SINGLE PHASE ELECTRICAL CONNECTIONSVORTICE-MP-254 T-Helical-Industrial-
Ventilation-fig-6

THREE-PHASE ELECTRICAL CONNECTIONSVORTICE-MP-254 T-Helical-Industrial-
Ventilation-fig-7 VORTICE-MP-254 T-Helical-
Industrial-Ventilation-fig-8

MAINTENANCE CLEANING

Cleaning and maintenance must be performed only by professionally qualified personnel.VORTICE-MP-254 T-Helical-Industrial-Ventilation-
fig-9 VORTICE-MP-254 T-Helical-
Industrial-Ventilation-fig-10

DISPOSAL

  • This product complies with Directive 2012/19/EU on the management of waste electrical and electronic equipment (WEEE).
  • The crossed-out wheeled bin symbol on the appliance indicates that, at the end of its useful life, the product must be taken to a specialized company for transport and treatment.
  • This company will take care of the disposal of the various materials making up the product and their subsequent proper recycling.
  • Alternatively, the manufacturer of the appliance is obliged to take back the product to be disposed of in exchange for the purchase of an equivalent appliance.
  • VORTICE S.p.A. reserves the right to make improvements to products at any time and without prior notice.

VORTICE GROUP COMPANIES

VORTICE INDUSTRIAL Srl

VORTICE LIMITED

Documents / Resources

| VORTICE MP 254 T Helical Industrial Ventilation [pdf] Instruction Manual
MP 254 T, MP 254 T Helical Industrial Ventilation, Helical Industrial Ventilation, Industrial Ventilation, Ventilation
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VORTICE User Manuals

Related Manuals