GOLDEN LIGHTING 3306-LP Orwell 3-Light Matte Black Clear Glass Crystal Linear Pendant Light Instruction Manual
- June 4, 2024
- GOLDEN LIGHTING
Table of Contents
- GOLDEN LIGHTING 3306-LP Orwell 3-Light Matte Black Clear Glass Crystal
- Pendants Types
- How to Identify the Fixture’s Wires
- Assembly Instructions
- PREPARING FOR INSTALLATION
- ASSEMBLING THE FIXTURE
- CONNECTING THE WIRES
- FINISHING THE INSTALLATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GOLDEN LIGHTING 3306-LP Orwell 3-Light Matte Black Clear Glass Crystal
Linear Pendant Light
Thank You for Choosing Golden Lighting for Your Lighting Needs!
Pendants Types
-
Pendants & Linear Pendants Above a Kitchen Island
Center a linear pendant over the island. If hanging pendants, use one pendant for every 24″ of island. Fixtures should hang at least 30″ above the countertop. -
Pendants & Chandeliers Above a Dining Room Table
Fixtures should stay at least 30″ above the table. Use a fixture that is 12″ narrower than the width of the table. -
Pendants and Chandeliers in Open Areas
The bottom should hang at least 7.5 feet from the floor. Allow clearance for any opening doors.
We appreciate your business and hope you love your new light!
Great lighting can add value and enhance the look of your home. To ensure the best lighting in your space, remember to layer your lighting. This ensures that your space will have both task and ambient lighting. Coordinating fixtures like sconces, flush mounts, and pendants can help you meet your layered lighting needs and reinforce your desired aesthetic. Install the lights with dimmers that allow you to control the level of light output at any given moment. Get function and style! Browse our site for coordinating lights and expert lighting advice. To help create the perfect look, visit www.GoldenLighting.com.
How to Identify the Fixture’s Wires
- Hot: Smooth, Black, or Transparent with Black Inner Thread
- Neutral: Ribbed, White or Transparent with White Inner Thread
- Ground: Copper, Bare Metal, Green, or Transparent Inner Thread
IMPORTANT:
- All installation work should be done by an accredited professional.
- Shut off power supply at fuse or circuit breaker!
- Use only the specified bulbs. Do not exceed the maximum wattage!
Assembly Instructions
PREPARING FOR INSTALLATION
Carefully remove the new fixture from the carton as well as the yellow bag
that holds all of the parts. See the important notes above. Shut off power
at the circuit breaker and remove the old fixtures from the wall, including
the old mounting strap. 1. Take the mounting strap assembly from the parts
bag. Mounting strap (B) contains several threaded holes. Two sets of mounting
screws (A & D) should be attached to mounting strap (B). You may need to
tighten nuts (C) that hold mounting screws (A) in place. If the screws are not
attached, please hold canopy (F) up to mounting strap (B). Line up the holes
in canopy (F) with the holes in mounting strap (B) and insert mounting screws
(A) into mounting strap (B) so that mounting screws (A) protrude through the
holes in canopy (F). Mounting screws (A) are long, so test canopy (F) against
the mounting strap and practice threading deco nuts (H) onto mounting screws
(A) to see how far you should insert mounting screws (A). Remove the deco nuts
and canopy. Tighten nuts (C) onto mounting screws (A) to hold the screws in
place. 2. Pull the house wires through the center of mounting strap (B). Place
mounting strap (B) over the junction box so that mounting screws (A) are
vertical, and in alignment with the hole locations on the fixture’s canopy
(F). Secure mounting strap (B) to the junction box with mounting screws (D)
and a screwdriver. Tighten the screws securely.
ASSEMBLING THE FIXTURE
3. If disconnected, feed fixture wire into center column (L) onto the post at the center of the fixture’s body. Rods (J & K) are on the fixture’s wires, but not connected to the fixture. Measure to determine the correct number of rods needed for proper hanging height. There are three 12-inch rods (K) and one 6-inch rod (J) included. To lengthen the fixture, add additional rods. If additional rods are needed, contact the place of purchase to order. To shorten the fixture, add at least 8 to 10 inches of wire to the desired length and trim the wires. Slide any excess rods off the fixture’s wires to discard. Pull the wires until taut before threading the rods together. Feed the fixture’s wires through desired rods (J & K) and swivel (G) of canopy (F). Thread together rods and then thread the bottom rod onto the post on the center column (L). Twist the top of the rods onto the threads of swivel post (G) of the canopy (F). Pull the wires until taut. Lock the rod in place by twisting screw (I).
CONNECTING THE WIRES
4. Have an assistant support the fixture’s weight while completing the wiring. Refer to the wiring diagram and attach the fixture’s wires to the power supply wires from the junction box. Attach the fixture’s wires to the power supply wires from the junction box. Connect Hot to Hot (transparent wire with black inner thread, black, or smooth wire) Neutral to Neutral (transparent wire with white inner thread, white, or ribbed wire), and Ground to Ground (transparent wire with green inner thread, green wire, or copper). Twist the ends of the wire pairs together, and then twist on a wire connector. Make sure all twists are in the same direction. If there is no house ground wire coming from the junction box, locate ground screw (E) on the mounting bracket/mounting strap and wrap the fixture’s ground wire around the ground screw. Use a screwdriver to tighten the top of ground screw (E) onto the wires and into the mounting bracket/mounting strap. Tuck the wires into the junction box.
FINISHING THE INSTALLATION
5. Push canopy (F) up to the ceiling and tightly thread nuts (H) onto the exposed threads of mounting screws (A). 6. Secure spider (N) to shades (Q) with screws (P) and decorative caps (O). Carefully slide assembled shades (Q) over sockets (M) and secure the shades in place with socket rings (R). Install light bulbs (not provided) into sockets (M) in accordance with the fixture’s specifications. Do not exceed the maximum wattage. Your installation is now complete. Turn on the power and test the fixture.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>