Therabody Theragun SENSE Massage Therapy for Pain Relief
Revision History
Modification date | Change description | Rev | Modified by |
---|---|---|---|
2023-4-24 | Initial release. | 1 | Team |
Specifications
- Model: Theragun SENSE
- Document No.: TG-TGSENSE-001
- Revision: 01
Basic Unit Characteristics
Indicator Light| YES
Housing Materials| PC
Additional Features
Environment for operation| Temperature: 0 ~ 40° C
Relative humidity: <93% RH
Environment for storage| Temperature: -10° C ~ 50° C
Relative humidity: 10~95% RH
---|---
Use atmospheric pressure| 70-106Kpa
Software version| V1.0
Recommendation of Use
The Theragun SENSE is recommended for use as a personal massage device to help
relieve muscle tension and improve circulation.
Device name :Theragun SENSE model :Theragun SENSE
Read the full Warnings and Guidance prior to using the Theragun SENSE.
- Provide a guided and non-guided in-dept massage therapy (percussion therapy) around the body to increase blood blow, reduce tension and knots, enhance pre and post workout routines leading to a faster recovery.
- Measure and report HR and HRV to the user as part, but not limited to, the preset programs
Relax and reduce stress throughout the smart sense technology (haptic vibration) This device is contraindicated against and should not be used by those with acute or severe cardiac, liver, or kidney disease/condition or other underlying conditions linked to these diseases. It is not recommended that this device is used overvarious skin infections and conditions, or directly over a surgical site/hardware, bone fracture, or if you are experiencing unexplained pain in the area. It isalso advised that this device is not used for those who have neurological and/or peripheral conditions as well as other conditions that may influence oralter sensation and perception. In the event of any adverse reaction, discontinue use. Please consult your physician prior to use if you are unsure if youhave any of the previously listed conditions. Immediately stop using the device at the first sign of discomfort. Adult supervision should be provided for those under the age of 18 using this device. If you have any medical concerns regarding the use of this device,please consult your physician prior to use. The Supersoft attachment should not be used more than 2 minutes at one time to avoid overheating and/or melting.
Contraindications
Before using the Theragun SENSE, please take note of the following
contraindications:
- Do not use on broken or injured skin.
- Avoid using near sensitive areas such as the eyes, genitals, or open wounds.
- Consult with a healthcare professional if you have any medical conditions or concerns.
The following are circumstances where the potential risks may outweigh the benefits. Consult a medical professional before use.
- Skin rash, open wounds, blisters, local tissue inflammation, bruises, infections or tumors
- Deep vein thrombosis, osteomyelitis
- Bone fracture or myositis ossificans
- Hypertension (uncontrolled)
- Acute or severe cardiac, liver, or kidney disease
- Neurologic conditions resulting in loss or altered sensation
- Direct application to the face, throat, or genitalia
- Bleeding disorders
- Recent surgery or injury
- Connective tissue disorders
- Peripheral vascular insufficiency or disease
- Medications that thin the blood or alter sensations
- Direct pressure over surgical site or hardware
- Direct pressure over eyes or throat
- Extreme discomfort or pain felt by client
- Severe scoliosis or spinal deformity
- Pacemaker, ICD, or history of embolism
For a full list of contraindications and additional warnings, please visit www.therabody.com. Patents & Pending Patents at www.therabody.com. Used to identify symptoms or medical conditions for a person to not receive a particular treat mentor procedure be cause it may be harmful.
- Neverusethisdeviceoveranydamagedtissueorothertypeofskinconditioncan result in delaying the best medical treatment.
- Do not use if you have had any surgery procedure–consult your doctor.
- Never use the device to the patient with Implant Electronic Devices(such as cardiac pace maker).‘
Precautions
Due care is required in these circumstances and the use of the devices may need to be modified (such as attachment used, the force applied, the position of the body, avoidance of use in direct contact with an area, etc.). Where appropriate or if you have any concerns, seek the advice of a medical professional.
- Hypertension (controlled)
- Osteopenia
- Osteoporosis
- Pregnancy
- Diabetes
- Varicose veins
- Bony prominences or regions
- Abnormal sensations (e.g., numbness)
- Sensitivity to pressure
- Recent injury or surgery
- Scoliosis or spinal deformity
- Medications that may alter client sensations
Warnings **
**
Please read and follow these warnings before using the Theragun SENSE:
- Do not use the device while driving or operating machinery.
- Avoid using the device if you are pregnant or have a pacemaker.
- Keep the device away from children and pets.
- Do not use the device for more than the recommended duration per session.
BEFORE USING THE OR CHARGING
THE Theragun SENSE, READ ALL THE INSTRUCTIONS AND CAUTIONARY MARKINGS IN THIS
MANUAL, O, AND ON Theragun SENSE. Theragun SENSE is intended for commercial or
home use. We strive to make the Theragun SENSE as safe as possible. This is an
advanced mechanical device with electric components. If the Theragun SENSE and
its accessories are not used or maintained properly, there is a risk of fire,
electric shock, or injury. Hazard can be result from unauthorized modification
of the Theragun SENSE
- Do not place your finger or any objects near the metal piston above the attachment while the Theragun SENSE is in use or immediately after use.
- The metal piston can become extremely hot.
- Do not use any attachments other than the ones provided by Therabody. and only as instructed by Therabody.
- Do not use Theragun SENSEon your head or near your genitals.
- Do not use Theragun SENSEabove the waist during pregnancy.
- Do not get hair caught in any moving part of the Theragun SENSE.
- Do not use tTheragun SENSE above your Adam’s Apple or C4.
- Do not get Theragun SENSE wet. Only clean Theragun SENSE with a magic eraser or a lightly damp towel.
- Do not block the vents of the motor.
- Never expose Theragun SENSE to water.
- For long-term storage, Theragun SENSE should be fully charged.
- This appliance is not intended to diagnose, treat, or prevent any diseases.
- This appliance contains batteries that are non-replaceable.
When using the Theragun SENSE, these basic precautions should always be followed including:
- USE ONLY AS INSTRUCTED. Use the Theragun SENSE as described in this Theragun SENSE Instruction Manual. Use only Theragun recommended accessories and replacement parts. Do not carry out any maintenance other than what is shown in the Theragun SENSE Instruction Manual or advised by Theragun.
- NOT FOR CHILDREN. TheTheragun SENSE are not intended for use by young children or persons with reduced physical, sensory or reasoning capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction by a responsible person. Do not allow the Theragun SENSE to be used as a toy. Close attention is necessary when used by or near children. Children should be supervised to ensure that they do not play with the Theragun SENSE
- CHARGING LOCATIONS. The Theragun SENSE should be charged indoors in a well ventilated, dry location. Do not charge Theragun SENSE outdoors, in a bathroom or within 10 feet (3.1 meters) of a bathtub, or pool. Do not use the Theragun SENSE on wet surfaces and do not expose product to moisture, rain, or snow. Do not use Theragun SENSE in the presence of explosive atmospheres (gaseous fumes, dust, or flammable materials). Sparks may be generated, possibly causing a fire.
- DO NOT OVERCHARGE. Do not leave connectTheragun SENSE to the charger for more than an hour after the Theragun SENSE has been fully charged. The Theragun SENSE includes a protection system to avoid the risk of overcharging, however, overcharging the Theragun SENSE may reduce its life over time. Can use the adaptor 5v-15v, 2.5A adaptor .
- DO NOT BLOCK MOTOR VENTS. Do not put any obstructions into vents. Do not use if any vent is blocked. Keep free of dust, lint, hair, and anything that may reduce airflow. Keep hair, loose clothing, and fingers from vents and moving parts.
- DO NOT BURN OR INCINERATE THE Theragun SENSE. The internal battery may explode, causing personal injury or damage. Toxic fumes and materials are created when battery is burned.
- DO NOT CRUSH, DROP, OR DAMAGE. Do not use a charger that has received a sharp blow, been dropped, run over, or damaged in any way.
- BATTERY CHEMICALS CAUSE SERIOUS BURNS. Never allow the internal battery to come into contact with the skin, eyes, or mouth. If a damaged battery leaks chemicals, use rubber or neoprene gloves to dispose of it. If skin is exposed to battery fluids, wash with soap and water and rinse with vinegar. If eyes are exposed to battery chemicals, immediately flush with water for 20 minutes and seek medical attention. Remove and dispose of contaminated clothing.
- DO NOT OPERATE UNDER BLANKET AND PILLOW. Excessive heating can occur and cause fire, electric shock, or injury to persons.
- STORING THE Theragun SENSE Store in a cool, dry place. Do not store the Theragun SENSE where temperatures may exceed 50°C/104°F such as in direct sunlight, in a vehicle, or metal building during the summer.
- DISPOSING OF BATTERIES. The internal Theragun Lithium-ion batteries for the Theragun SENSE are more environmentally friendly than some other types of batteries (e.g., nickel-cadmium). Always dispose of the Theragun SENSE according to federal, state, and local regulations. Contact a recycling agency in your area for recycling locations. Even discharged batteries contain some energy. Before disposing, use electrical tape to cover the Theragun SENSE’s 12V connecter to prevent the battery from shorting, which could cause a fire or explosion.
- DO NOT DISASSEMBLE. Disassembly or incorrect reassembly may result in the risk of electric shock, fire, or exposure to battery chemicals. The warranty will be void if the Theragun SENSE are disassembled or if any parts have been removed.
- SERVICE. If the Theragun SENSE is not working properly, has received a sharp blow, has been dropped, damaged, left outdoors, or dropped into water, do not use and contact Theragun by emailing info@therabody.com for repair or service. Do not attempt to repair or disassemble the Theragun SENSE which may result in an electric shock or fire.
- DO NOT USE WHILE BATHING OR IN THE SHOWER, TUB, OR SINK. Do not place or store the Theragun SENSE where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid. Do not reach for an appliance that has fallen into water. Unplug immediately.
- THERMAL LIMITER. The Theragun SENSE employs an automatic reset thermal limiter that shuts off the Theragun SENSE to prevent overheating and fire.
Strangulation due to cables and hoses particularly due to excessive length Potential allergic reactions to accessible materials used in the ME EQUIPMENT Available for immediate use when device cool from the maximun storage temperature between uses and Device warm from the minimum storage temperature between uses.
Label & Symbols
The Theragun SENSE features the following labels and symbols:
- Power button: Turns the device on/off.
- Speed control: Adjusts the speed of the massage.
- Battery indicator: Shows the remaining battery level.
- Attachment indicator: Indicates the attachment being used.
The following labels and symbol sappearon Theragun SENSE:
Intended Use & Indications for Use
The Theragun SENSE is intended for use as a personal massage device to help
relieve muscle soreness and improve recovery. It can be used on various muscle
groups, including the back, legs, arms, and shoulders.
- Provide a guided and non-guided in-dept massage therapy (percussion therapy) around the body to increase blood blow, reduce tension and knots, enhance pre and post workout routines leading to a faster recovery.
- Measure and report HR and HRV to the user as part, but not limited to, the preset programs Relax and reduce stress throughout the smart sense technology (haptic vibration)s.
Device Description **
**
The Theragun SENSE is a handheld percussion massage device that utilizes advanced technology to deliver deep and targeted muscle treatment.
It features the following components:
-
A High-res color display screen
-
B Button pad
-
C Theragun Triangle ergonomic handle design
-
D USB-C Port
-
E Proprietary brushless commercial-grade motor with Quiet Force Technology™
-
F 16mm amplitude for deep muscle treatment
-
G Interchangeable attachments
Device Certification display in Screen guide as below :
Information about your device’s certification can be found in your device’s
settings. To access your device’s settings. long press the center button to
power the device on. Press the down button to toggle through the routines
until you reach “Settings.” Select your device and press the down button to
view device certificate information.
Smart Features
- Bluetooth connectivity: Allows for wireless control and customization of massage settings through a mobile app.
- Smart Touch Control: Enables easy operation and adjustment of speed settings with a simple touch.
- Smart App Integration: Provides personalized massage programs and tracking of usage and performance.
Theragun SENSE is smart device enabled with Bluetooth connectivity, designed to pair seamlessly with the Therabody app. When you download the app, you’ll be guided through a step-by-step setup and shown how to pair your device. Once paired with your device, the app can remotely adjust speed, activate guided treatment presets, and make real-time recommendations based on your feedback and recent activity. It’s truly your intuitive wellness partner on your journey to feeling better and moving more freely. Every day.
Scan the QR code to get started.
Attachments
The Theragun SENSE comes with a variety of interchangeable attachments to
target different muscle groups and provide various massage techniques.
The attachments include:
- Dampener: Ideal for tender or bony areas.
- Standard Ball: Suitable for overall use on large muscle groups.
- Cone: Targets specific areas such as trigger points or knots.
- Thumb: Designed for lower back and trigger point therapy.
Attachments | QTY | Using | Figure |
---|---|---|---|
Dampener | 1 | For use on tender areas or near bones | |
Standard Ball | 1 | For overall, general use | |
Thumb | 1 | For lower back and trigger point therapy | |
Wedge | 1 | For scraping, shoulder blades, or IT bands | |
--- | --- | --- | --- |
Accessories
In addition to the attachments, the Theragun SENSE package includes the
following accessories:
- Charging cable: Used to charge the device.
- Carrying pouch: Provides convenient storage and portability.
- User manual: Contains detailed instructions on how to use the device.
A type-c (USB-C to USB-C SENSE USB-Aor Use C to C)Line is provided together with the Theragun SENSE.
Getting Started **
**
Before using the Theragun SENSE, please follow these steps:
- Ensure the device is fully charged by connecting it to the charging cable and a power source.
- Select the desired attachment based on your target muscle group and desired massage technique.
- Turn on the device by pressing the power button.
- Adjust the speed settings using the speed control button or the mobile app, if connected.
- Apply gentle pressure to the desired area and move the device in a slow, circular motion for 1-2 minutes per muscle group.
- After each use, clean the attachments according to the cleaning instructions provided.
Step 1 Turn on and float
Firmly press and hold the center button on the button pad, then float the
Theragun SENSE across areas in need. Use the up (Λ) and down (v) buttons on
the button pad to adjust speed. Apply light to moderate pressure as needed.
Step 2 Get the Therabody app
We’ll guide you through a stress-free setup and show you how to get the most
out of your fully personalized app experience.
Step 3 Feel the difference.™ Every day.
Take a deep breath and treat yourself with guided treatment presets or go
freestyle with 5 preset speeds. It’s all designed for you.
Set up : Select “▶” on the main interface, press the middle button, and
the device enters the start and operation interface, and starts to run from
1750rpm. Time timing is displayed at the top of the interface, pressure bar is
displayed in the middle, speed value is displayed below the pressure bar, and
“II” sign is displayed below. Short press the top button to increase speed,
short press the bottom button to reduce speed. Press the middle button to stop
the device and return to the main interface. Align the massage head with the
tip of the rotating elbow arm and press in before using the device. To remove
the massage head, hold the massage head, place your fingers on each side of
the plastic joint, and pull down the massage head.
( Note 1: There are 5 pressure bars, and each one turns blue, indicating
that the pressure is increasing. Note 2:5 options for speed value,
1750-1900-2100-2200-2400) holding down the middle button will turn off the
device at any time.
HR sensor: Double click the heart rate sensor with your finger to enter
the heart rate detection interface, accompanied by the release of the
vibration motor. Do not move your finger on the heart rate detection site.
After the heart rate is measured and displayed on the screen. Double-click the
heart rate detection and return to the main interface or press the center
button to return to the main interface (the heart rate graph is displayed at
the top of the heart rate detection interface, HR value is displayed in the
middle and HRV value is displayed at the bottom).Holding down the middle
button will turn off the device at any time
Using theTheragun SENSE
- To turn on the Theragun SENSE, firmly press and hold the center button on the button pad.
- Press the up (Λ) and down (v) arrows to toggle between 5 preset speeds and adjust your treatment level.
- To turn off the Theragun SENSE, firmly press and hold the center button on the button pad.
Connecting the Attachments
To connect an attachment to the Theragun SENSE, follow these steps:
- Align the attachment with the attachment indicator on the device.
- Press the attachment firmly into place until it clicks into position.
- Ensure the attachment is securely attached before using the device.
Align the attachment with the tip of the rotating arm and push to connect. To remove, grip the attachment, placing 1 finger on each side of the plastic connector. Pull off the attachment.
Charging the Theragun SENSE
- Your device includes a USB-C to USB-C SENSE USB-A cable so you can use a wider variety of adapters. The 3 circular LED lights on the control panel of the deviceindicate battery level
- The LED battery indicator, located under the 5 LED speed indicator bars, will start flashing.
- Charging is complete when all 3 LED lights of the LED battery indicator are lit.
To charge the Theragun SENSE, follow these steps:
- Connect one end of the charging cable to the charging port on the device.
- Connect the other end of the charging cable to a power source.
- The battery indicator will show the charging progress, and it will turn solid when fully charged.
- It is recommended to fully charge the device before the first use and whenever the battery is low.
Cleaning Instructions
To clean the Theragun SENSE and its attachments, please follow these
guidelines:
- Turn off the device and remove the attachment.
- Wipe the device and attachment with a clean, damp cloth.
- Avoid using harsh chemicals or solvents.
- Allow the device and attachments to air dry before storing or reusing.
For the most hygienic Theragun device experience, sanitize it after each use by:
- Wiping the device with a disinfectant wipe to remove any residue.
- Once the device is residue-free, use a new wipe to disinfect the surface area by wiping all sides in a downward motion.
Troubleshooting
Problem: Device turns off automatically
Possible Solution: The device may have reached the set time limit or have
low power. Please charge the device or adjust the session duration
accordingly.
In the event that the device fails to perform as intended, the following notes
will help to identify potential problems with the device and its setup.
Problem | Solution |
---|---|
Device turns off automatically | Maybe reach the set time or low power |
Device cannot turn on | Maybe battery is in low power and you should recharge |
batteries. .
Device shuts off in mid-treatment or only after few treatments| Check and
recharge batteries.
Cannot charge battery| Check if the adapter output connector insert into the
charging port in the device firmly
Service
Operation Instruction has no parts you can fix. Do not try to repair it.
Ifservicing is required, please contact the selling retailer. All returned
units to the manufacturer for repair, including Warranty repair and Out-Of-
Warranty repair, must include the following: During Warranty Period with proof
of Purchase (store receipt).
RMA Number: Should your product become defective during the warranty
period, call our service center or contact your retailer.
Package the item securely and return it prepaid/insured – along with proof
of purchase to:
Therabody, Inc.
6100 Wilshire Blvd. Suite 200 Los Angeles, CA 90048-5107, USA
To ensure prompt repair, provide complete, legible name, address and phone
number information, RMA number and a note indicating the nature of the product
defect and a copy of the original invoice issued for purchase of the unit. We
willRepair or Replace (at our sole discretion) product at no charge. Ship unit
to themanufacturer in the original container with all accessories and
information asrequired above.
Service Life
When used and maintained as instructed, the expected service life of Theragun
SENSE two years.
Safety, EMCRF
This device is Class II equipment with type BF applied. It complies with Medical Electrical Safety Standards (IEC 60601-1). This device also complies with Medical EMC Standard (IEC 60601-1-2). The has been tested and found to comply with the electromagnetic compatibility (EMC) limits for medical devices to IEC 60601-1-2: 2007. These limits aredesigned to provide reasonable protection against harmful interference in a typical medical installation.
CAUTION:
Do not apply the device near any devices with Electromagnetic Interference
(EMI), such as cell phones, Magnetic Resonance Imaging (MRI), computerized
axial tomography (CT), diathermy, Radio Frequency Identification (RFID), etc.
or MR environment. EMI, RF devices or MR environment may affect the normal
function of the device or would cause user injury. The patient is an intended
operator. The ME EQUIPMENT shall not be serviced or maintained while in use
with a patient.
Manufacturer’s declaration – electromagnetic immunity
- WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use isnecessary, this equipment and the other equipment should be observed to verify thatthey are operating normally.”
- Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.”
- Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the ME EQUIPMENT, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment couldresult.”
- Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Innovation, Science, and Economic Development Canad licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
This device complies with FCC/ISEDC radiation exposure requirement set forth for an uncontrolled environment. The transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
declaration-electromagn eticemission
Emissions test| Compliance
RF emissions
CISPR11| Group1
RF emissions
CISPR11| Class B
Harmonic emissions
IEC61000-3-2| Not applicable
Voltage fluctuations/ flick eremissions IEC61000-3-3| Not applicable
declaration-electromagnetic immunity
Immunity test| IEC60601testlevel| Compliance level
Electrostatic| ±8kVcontact| ±8 V contact
discharge (ESD)| ±2kV,±4kV,±8kV,±15 k Vair| ±2 V,±4kV,±8kV,±15kVair
IEC61000-4-2| |
Electricalfasttr ansient/burst| ±2kVforpower supply lines| Not applicable
IEC61000-4-4| ±1kVforinput/output lin|
| es|
Surge
IEC61000-4-5| ±0.5kV,±1kVline(s)
to lines| Not applicable
| ±0.5kV,±1kV,±2kVline(|
| s)to earth|
Voltage dips, short| 0%| Not applicable
interruptions| UT;0.5cycleat0°,45°,90|
and voltage| °,135°,180°,225°,270°a|
variationson| nd|
power supply| 315°|
input lines| |
IEC61000-4-| 0%|
11| UT;1cycleand70%UT;2|
| 5/30cycles|
| Singlephase:at0°|
| 0%UT;250/300|
| cycles|
Power
frequency
(50/60Hz)ma genetic field| 30A/m| 30A/m
IEC61000-4-8| |
---|---|---
NOTE:UT is the a.c. mains voltage prior to application of the test level.
declaration-electromagnetic immunity
Immunity test| IEC60601test level| Compliance level
Conducted| 3V| Not applicable
RF| |
| 0.15MHzto80M|
IEC61000-4-| Hz|
6| 6VinISMbandsbet|
| ween0.15MHzan|
| d80MHz|
Radiated RF| 10V/m| 10V/m
IEC61000-4-| 80MHzto2.7|
3| GHz|
declaration-IMMUNITY to proximity fields from RF wireless communication
sequipment
Immunity test| IEC60601testlevel| Compliance level
Test frequency| Modulation| Maximum
power| Immunity level
Radiated| 385MHz| **Pulse| 1.8W| 27V/m| 27V/m
RF| | Modulation:| | |
IEC 61000-4- 3
| | 18Hz| | |
450MHz| *FM SENSE5 Hzdeviati| 2W| 28V/m| 28V/m
| | on:1kHzsi| | |
| | ne| | |
| 710MHz| Pulse| 0.2W| 9V/m| 9V/m
| 745MHz| Modulation: 217Hz| | |
| 780MHz| | | |
| 810MHz| Pulse| 2W| 28V/m| 28V/m
| 870MHz| Modulation: 18Hz| | |
| 930MHz| | | |
| 1720| Pulse| 2W| 28V/m| 28V/m
| MHz| Modulation:| | |
| 1845| 217Hz| | |
| MHz| | | |
| 1970| | | |
| MHz| | | |
| 2450| Pulse| 2W| 28V/m| 28V/m
| MHz| Modulation:| | |
| | 217Hz| | |
| 5240| **Pulse| 0.2W| 9V/m| 9V/m
| MHz| Modulation:| | |
| 5500| 217Hz| | |
| MHz| | | |
| 5785| | | |
| MHz| | | |
Note- As analternative to FM modulation,50% pulse modulation at 18Hz may be used because while it does not represent actual modulation, it would be the worst case.
- The carrier shall be modulated using a 50% duty cycles quare wave signal.
Manufacturer Information
Therabody, Inc.
6100 Wilshire BIvd., Suite 200 Los Angeles CA 90048-5107, USA
LIMITED WARRANTY
For full warranty information, please visit
www.therabody.com/warranty.
To request acopy of the warranty by mail, you may send are quest to the
following address:
Therabody-Warranty
Attn: Customer Service
Therabody, Inc.
6100 Wilshire Blvd., Suite 200 Los Angeles CA 90048-5107,USA
Please note, this is not are turn address or are tail location. No Theragun
Products or packages will be accepted at this location.
The E-label information
Access to the required information on the e-label
-
Users are able to access the information in no more than three steps in a device’ s menu.
The actual steps are:
To access the e-label information, in the device, Choose: Settings >Device No special access codes or permissions are required to go through the above steps. -
The information is stored on the device, no special accessories or supplemental plug-ins (e.g.,a SIM/USIM card) are required to access the information.
Yes -
Users are provided specific instructions on how to access the information.
The information to the user is provided in the E-label Info document.
Detailed as follows:
Switch downin the menu to find and select Settings.
Switch down in Settings to find and select Device.
The e-label will display Regulatory information
Labeling for lmportation and Purchasing
-
Products utilizing e-labels are required to have a physical label on the product at the time of1.importation, marketing and sales. For devices imported in bulk and not packaged individually, a removable adhesive label or, for devices in protective bags, a label on the bags is acceptable for this purpose. Any removable label shall be of a type intended to survive normal shipping and handling and must only be removed by the customer after purchase. For devices imported already in individual packages ready for sale, the information may alternatively be provided on the package.
lt shall contain: -
The FCC ID and/or the DoC logo (if applicable); and
-
Any other information required by specific rule to be provided on the surface of the product unless such information is permitted to be included in the User’ s manual or other packaging inserts.
Other considerations
- The above information must be programmed by the responsible party and the information must be secured in such a manner that third-parties cannot modify it. The e-label information is pre-programmed by the grantee. The user cannot modify the e-label information.
FAQ
-
Q: Can I use the Theragun SENSE on my face?
A: No, it is not recommended to use the Theragun SENSE on the face. Avoid using it near sensitive areas such as the eyes and genitals. -
Q: How often should I clean the attachments?
A: It is recommended to clean the attachments after each use to maintain hygiene and prevent the buildup of dirt or oils. -
Q: Can I use the Theragun SENSE while charging?
A: Yes, you can use the Theragun SENSE while it is charging. However, it is recommended to fully charge the device before using it for an extended period.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>