POLAR UA024 U-Series 3 Door Counter Fridge with Glass Doors Instruction Manual
- June 4, 2024
- Polar
Table of Contents
UA024 U-Series 3 Door
Counter Fridge with Glass Doors
Instruction Manual
Safety Instructions
Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.
-
Position on a flat, stable surface.
-
A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.
-
Consult Local and National Standards to comply with the following:
– Health and Safety at Work Legislation
– BS EN Codes of Practice
– Fire Precautions
– IEE Wiring Regulations
– Building Regulations -
DO NOT use jet/pressure washers to clean the appliance.
-
DO NOT use the appliance outside.
-
DO NOT use this appliance to store medical supplies.
-
DO NOT stand or support yourself on the base, drawers, or doors.
-
DO NOT allow oil or fat to come into contact with the plastic components or door seal. Clean immediately if contact occurs.
-
Bottles that contain a high percentage of alcohol must be sealed and placed vertically in the refrigerator.
-
Always carry, store and handle the appliance in a vertical position and move by holding the base of the appliance.
-
Always switch off and disconnect the power supply to the unit before cleaning.
-
Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.
-
Children should be supervised to ensure that they do not play with the appliance.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
-
POLAR recommends that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity, and Functional Testing.
-
POLAR recommends that this product is connected to a circuit protected by an appropriate RCD (Residual Current Device).
Caution: Risk of Fire
-
Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
Warning : Keep all ventilation openings clear of obstruction. The unit should not be boxed in without adequate ventilation. -
Warning : Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
-
Warning : Do not damage the refrigerant circuit.
-
Warning : Do not use electrical appliances inside the food storage compartments of the appliance, unless they are the type recommended by the manufacturer.
Pack Contents
The following is included:
- POLAR Refrigerator
- Instruction Manual
POLAR prides itself on quality and service, ensuring that at the time of
packaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your POLAR
dealer immediately.
Installation
Note : If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before the operation. If in doubt allow standing.
-
Remove the appliance from the packaging.
Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces. -
To optimize performance and longevity, ensure a minimum clearance of 2.5cm is maintained between the unit and walls and other objects, with a minimum of 5cm clearance on the top.
NEVER LOCATE NEXT TO A HEAT SOURCE.
Note: Before using the appliance for the first time, clean the shelves and interior with soapy water.
-
Set the brakes on the castors to keep the appliance in position.
Operation
Control Panel
A – Power Switch
B – Light Switch
Turn On
- Close the door(s) of the appliance.
- Switch on the Power Switch [I]. The current temperature within the appliance is displayed.
- Turn the light switch On [I] or Off [O] as desired.
Set the Operating Temperature
- Hold the SET button for 3 seconds. The value of the current set point will be displayed.
- Press the or buttons to display the required temperature.
- Press the SET button to store the temperature.
Manual Defrost
Press and hold the defrost button “aux” for 2 seconds to begin a manual
defrost. The defrost light illuminates.
Cleaning, Care & Maintenance
- Switch off and disconnect from the power supply before cleaning.
- Clean the interior of the appliance as often as possible.
- Do not use abrasive cleaning agents. These can leave harmful residues.
- Clean the door seal with warm soapy water.
- Always wipe dry after cleaning.
- Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
- Take care when cleaning the rear of the appliance. Sharp edges can be cut.
Condensation will form in refrigeration with the frequent opening of the doors and on hot humid days, please ensure condensation is allowed to drain properly or is wiped dry.
Condenser Cleaning
- The condenser is part of the refrigeration system. The condenser requires monthly cleaning.
- Always disconnect the power supply before carrying out Routine Maintenance.
- Failure to clean the condenser will reduce the performance and life of your Polar unit and may invalidate your warranty.
- These models have a removable filter that can be cleaned with a vacuum cleaner.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault | Probable Cause | Solution |
---|---|---|
The appliance is not working | The unit is not switched on | Check the unit is |
plugged in correctly and switched on
Plug or lead is damaged| Replace plug or lead
The fuse in the plug has blown| Replace the fuse
Mains power supply fault| Check mains power supply
The appliance turns on, but the temperature is too high/low| Too much ice on
the evaporator| Defrost the appliance
Condenser blocked with dust| Clean the Condenser
Doors are not shut properly| Check doors are shut and seals are not damaged
The appliance is located near a heat source or air flow to the condenser is
being interrupted| Move the refrigerator to a more suitable location
The ambient temperature is too high| Increase ventilation or move the
appliance to a cooler position
Unsuitable foodstuffs are being stored in the appliance| Remove any excessive
hot foodstuffs or blockages to the fan
Appliance is overloaded| Reduce the amount of food stored in the appliance
The appliance is leaking water| The appliance is not properly leveled| Adjust
the screw feet to level the appliance (if applicable)
The discharge outlet is blocked| Clear the discharge outlet
The movement of water to the drain is obstructed| Clear the floor of the
appliance (if applicable)
The drip tray is overflowing| Empty the drip tray (if applicable)
The appliance is unusually loud| Loose nut/screw| Check and tighten all nuts
and screws
The appliance has not been installed in a level or stable position| Check
installation position and change if necessary
Technical Specifications
Model| Voltage| Power| Current| Temperature Range|
Refrigerant| Dimensions
1.1xWxDmm| Weight
(kg)
---|---|---|---|---|---|---|---
UA023| 220-240W,
50Hz| 300W| 1.8A| 2°C – 8°C| R600a 95g| 860 x 1360 x
700| 98
UA024| 300W| 1.8A| 2°C – 8°C| R600a 95g| 860 x 1795 x
700| 134
Electrical Wiring
POLAR appliances are supplied with a 3-pin BS1363 plug and lead.
The plug is to be connected to a suitable main socket.
POLAR appliances are wired as follows:
- Live wire (colored brown) to the terminal marked L
- Neutral wire (colored blue) to the terminal marked N
- Earth wire (colored green/yellow) to terminal marked E
This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency, disconnection is required they must be readily accessible.
Disposal
EU regulations require refrigeration products to be disposed of by specialist
companies who remove or recycle all gasses, metal, and plastic components.
Consult your local waste collection authority regarding the disposal of your
appliance. Local authorities are not obliged to dispose of commercial
refrigeration equipment but may be able to offer advice on how to dispose of
the equipment locally.
Alternatively, call the POLAR helpline for details of national disposal
companies within the EU.
Compliance
**** The WEEE logo on this product or its documentation indicates that the
product must not be disposed of as household waste. To help prevent possible
harm to human health and/or the environment, the product must be disposed of
in an approved and environmentally safe recycling process. For further
information on how to dispose of this product correctly, contact the product
supplier, or the local authority responsible for waste disposal in your area.
POLAR parts have undergone strict product testing in order to comply with
regulatory standards and specifications set by international, independent, and
federal authorities.
POLAR products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or
transmitted in any form or by any means, electronic, mechanical, photocopying,
recording, or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to
press, however, POLAR reserve the right to change specifications without
notice.
DECLARATION OF CONFORMITY
• Conformiteitsverklaring
Equipment Type | Model |
---|
U-Series 2 Door Counter with Glass Doors
U-Series 3 Door Counter with Glass Doors| UA023 (-E & -A)
UA024 (-E & -A)
Application of Territory Legislation & Council Directives(s)| Machinery
Directive 2006/42/EC
Supply of Machinery (Safety) Regulations 2008 EN 60335-1:2012 +A11:2014
+A13:2017 +A1:2019 +A14:2019 +A2:2019
EN 60335-2-89:2010 +A1:2016 +A2:2017
EN 62233:2008
Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU – recast of
2004/108/EC Electromagnetic Compatibility Regulations 2016 (S.I. 2016/1091)
EN 55014-1: 2017
EN 55014-2:2015
EN 61000-3-2: 2014
EN 61000-3-3:2013
Regulation (EU) 2019/2024 – Ecodesign direct sales refrigerators
ISO 23953-2:2015
Restriction of Hazardous Substances Directive (RoHS) 2015/863 amending Annex
II to Directive 2011/65/EU
Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic
Equipment Regulations 2012 (St 2012/3032)| Electrical Safety
IEC 60335-1:2010 +A1:2013 +A2:2016 IEC 60335-2-89:2010 +A1:2012 +A2:2015
Electromagnetic Compatibility
EN 55014-1: 2017 EN 55014-2:2015 EN 61000-3-2: 2014 EN 61000-3-3: 2013
Producer Name| Polar
I, the undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s), and Standard(s).
Date
Signature Full Name
Ashley Hooper | Eoghan Donnellan | Nerida Pearse |
---|
Position
Technical & Quality Manager| Commercial Manager/ Importer| Commercial Manager/
Responsible Supplier
---|---|---
Producer Address
Fourth Way, Avonmouth, Bristol, BS11 8TB
United Kingdom| 42 North Point Business Park New Mallow Road
Cork Ireland| 15 Bagdally Road, Campbelltown NSW 2560
---|---|---
+44 (0)845 146 2887
http://www.polar-
refrigerator.com/
UA023-UA024_ML_A5_v1_20220211
Documents / Resources
|
POLAR UA024 U-Series 3 Door Counter Fridge with Glass
Doors
[pdf] Instruction Manual
UA024 U-Series 3 Door Counter Fridge with Glass Doors, UA024 U-Series, 3 Door
Counter Fridge with Glass Doors, Fridge with Glass Doors, Glass Doors, Doors
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>