MEAN WELL LOP-300 Series 300W 4 Inch ×2 Inch Low Profile Open Frame Power Supply Owner’s Manual

June 15, 2024
MEAN WELL

MEAN WELL LOP-300 Series 300W 4 Inch ×2 Inch Low Profile Open Frame Power

Supply

Features

  • MEAN WELL Patent Number: ZL 202223277512.1
  • 4″×2″ compact size with low profile (25.4mm)
  • 80~264Vac input with PFC, No load power consumption<0.5W
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)
  • 150%peak load @ 3s
  • 180 W convection, 300W with FAN 10.98CEM forced-cooled
  • Suitable for Class I or Class II installations
  • Over voltage category III (OVC III)
  • -40 ~ +80°C wide range operation temperature
  • High efficiency up to 94%
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Extremely low leakage current
  • Operating altitude up to 5000 meters
  • Built-in 12V/0.5A for external FAN
  • 3 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Power sourcing equipment of PoE
  •  Medical devices

 GTIN CODE

Description

LOP-300 is a 300W highly reliable green PCB type low profile power supply with a high power density (37.5W/in*) on the 4″ by 2″ footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 54V. The working efficiency is up to 94% and the extremely low no load powerconsumption is down below 0.5W.
LOP-300 is able to be used for both Class I (with FG) and Class I(no FG) system design. LOP-300 is equipped with complete protection functions; It is complied with the international safety regulations such as IEC/BS EN/EN/UL62368-1,IEC/BS EN/EN60335-1,IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60601-1.LOP-300 serves as a high price-to-performance power supply solution for various industrial applications.The extremely low leakage current is less than 500 A.In addition, it conforms to the international medical regulations (2 MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment

Model Encoding

SPECIFICATION

MODEL| LOP-300-12| LOP-300-15| LOP-300-18| LOP-300-24| LOP-300-27| LOP-300-30| LOP-300-36| LOP-300-48| LOP-300-54
---|---|---|---|---|---|---|---|---|---











OUTPUT

| DC VOLTAGE| 12V| 15V| 18V| 24V| 27V| 30V| 36V| 48V| 54V


CURRENT

| Peak(3sec.)| 37.5A| 30A| 25A| 18.8A| 16.7A| 15A| 12.5A| 9.4A| 8.3A
10.98CF M| 25A| 20A| 16.7A| 12.5A| 11.1A| 10A| 8.3A| 6.3A| 5.6A
Convection| 15A| 12A| 10A| 7.5A| 6.7A| 6A| 5A| 3.8A| 3.4A


RATED POWER

| Peak(3sec.)| 450W| 450W| 450W| 450W| 450W| 450W| 450W| 450W| 450W
10.98CF M| 300W| 300W| 300.6W| 300W| 299.7W| 300W| 299.8W| 302.4W| 302.4W
Convection| 180W| 180W| 180W| 180W| 180.9W| 180W| 180W| 182.4W| 183.6W
RIPPLE & NOISE (max.)

Note.2

| 120mVp-p| 150mVp-p| 180mVp-p| 200mVp-p| 200mVp-p| 250mVp-p| 250mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE

(MAIN OUTPUT)

| 11.4~12.6V| 14.3~15.8V| 17.1~18.9V| 22.8~25.2V| 25.6 ~ 28.4V| 28.5 ~31.5V| 34.2 ~37.8V| 45.6 ~50.4V| 52 ~58V
VOLTAGE TOLERANCE

Note.3

| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC         1500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms@180W load , 8ms@300W load





INPUT

| VOLTAGE RANGE Note.4| 80 ~ 264VAC         113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 92.5%| 93%| 93.5%| 93%| 93%| 93%| 94%| 94%| 94%
AC CURRENT (Typ.)| 3.5A/115VAC  1.8A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC         80A/230VAC
LEAKAGE CURRENT| Earth leakage current < 500μA(rms) @ 264VAC , touch current < 70μA(rms) @ 264VAC




PROTECTION

| ****

OVERLOAD

| 105 ~ 150% rated output power, Protection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed


OVER VOLTAGE

| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 19.8 ~ 23.4V| 26.4 ~ 31.2V| 29.7 ~ 35.1V| 33 ~ 39V| 39.6 ~ 46.8V| 52.8 ~ 62.4V| 59.4 ~ 67.5V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover
FUNCTION| EXTERNAL FAN SUPPLY| 12V@0.5A for driving a fan / 12V@0.1A without fan cooling ; (10.98CFM) tolerance -20% ~ +15% at main output 20% rated current




ENVIRONMENT

| WORKING TEMP.| -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

MEAN-WELL-LOP-300-Series-300W-4-Inch ×2-Inch-Low-Profile-Open-Frame-Power-
Supply-fig-8

Block Diagram

Output Derating VS Input Voltage

Mechanical Specification

Installation Manual

Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals