MEAN WELL LOP-300 Series 300W 4 Inch ×2 Inch Low Profile Open Frame Power Supply Owner’s Manual
- June 15, 2024
- MEAN WELL
Table of Contents
MEAN WELL LOP-300 Series 300W 4 Inch ×2 Inch Low Profile Open Frame Power
Supply
Features
- MEAN WELL Patent Number: ZL 202223277512.1
- 4″×2″ compact size with low profile (25.4mm)
- 80~264Vac input with PFC, No load power consumption<0.5W
- Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)
- 150%peak load @ 3s
- 180 W convection, 300W with FAN 10.98CEM forced-cooled
- Suitable for Class I or Class II installations
- Over voltage category III (OVC III)
- -40 ~ +80°C wide range operation temperature
- High efficiency up to 94%
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Extremely low leakage current
- Operating altitude up to 5000 meters
- Built-in 12V/0.5A for external FAN
- 3 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Power sourcing equipment of PoE
- Medical devices
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN aspx
Description
LOP-300 is a 300W highly reliable green PCB type low profile power supply with
a high power density (37.5W/in*) on the 4″ by 2″ footprint. It accepts
80~264VAC input and offers various output voltages between 12V and 54V. The
working efficiency is up to 94% and the extremely low no load powerconsumption
is down below 0.5W.
LOP-300 is able to be used for both Class I (with FG) and Class I(no FG)
system design. LOP-300 is equipped with complete protection functions; It is
complied with the international safety regulations such as IEC/BS
EN/EN/UL62368-1,IEC/BS EN/EN60335-1,IEC/BS EN/EN61558-1/-2-16, IEC/BS
EN/EN60601-1.LOP-300 serves as a high price-to-performance power supply
solution for various industrial applications.The extremely low leakage current
is less than 500 A.In addition, it conforms to the international medical
regulations (2 MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF
rated “patient contact” medical system equipment
Model Encoding
SPECIFICATION
MODEL| LOP-300-12| LOP-300-15| LOP-300-18|
LOP-300-24| LOP-300-27| LOP-300-30| LOP-300-36|
LOP-300-48| LOP-300-54
---|---|---|---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 15V| 18V| 24V| 27V| 30V| 36V| 48V| 54V
CURRENT
| Peak(3sec.)| 37.5A| 30A| 25A| 18.8A| 16.7A| 15A| 12.5A| 9.4A| 8.3A
10.98CF
M| 25A| 20A| 16.7A| 12.5A| 11.1A| 10A| 8.3A| 6.3A| 5.6A
Convection| 15A| 12A| 10A| 7.5A| 6.7A| 6A| 5A| 3.8A| 3.4A
RATED POWER
| Peak(3sec.)| 450W| 450W| 450W| 450W| 450W| 450W| 450W| 450W| 450W
10.98CF
M| 300W| 300W| 300.6W| 300W| 299.7W| 300W| 299.8W| 302.4W| 302.4W
Convection| 180W| 180W| 180W| 180W| 180.9W| 180W| 180W| 182.4W| 183.6W
RIPPLE & NOISE (max.)
Note.2
| 120mVp-p| 150mVp-p| 180mVp-p| 200mVp-p| 200mVp-p| 250mVp-p| 250mVp-p|
250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE
(MAIN OUTPUT)
| 11.4~12.6V| 14.3~15.8V| 17.1~18.9V| 22.8~25.2V| 25.6 ~ 28.4V| 28.5 ~31.5V|
34.2 ~37.8V| 45.6 ~50.4V| 52 ~58V
VOLTAGE TOLERANCE
Note.3
| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at
full load
HOLD UP TIME (Typ.)| 16ms@180W load , 8ms@300W load
INPUT
| VOLTAGE RANGE Note.4| 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 92.5%| 93%| 93.5%| 93%| 93%| 93%| 94%| 94%| 94%
AC CURRENT (Typ.)| 3.5A/115VAC 1.8A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC 80A/230VAC
LEAKAGE CURRENT| Earth leakage current < 500μA(rms) @ 264VAC , touch
current < 70μA(rms) @ 264VAC
PROTECTION
| ****
OVERLOAD
| 105 ~ 150% rated output power, Protection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed
OVER VOLTAGE
| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 19.8 ~ 23.4V| 26.4 ~ 31.2V| 29.7 ~ 35.1V| 33 ~
39V| 39.6 ~ 46.8V| 52.8 ~ 62.4V| 59.4 ~ 67.5V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, recovers
automatically after temperature goes down or re-power on to recover
FUNCTION| EXTERNAL FAN SUPPLY| 12V@0.5A for
driving a fan / 12V@0.1A without fan cooling ;
(10.98CFM)
tolerance -20% ~ +15% at main output 20% rated current
ENVIRONMENT
| WORKING TEMP.| -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Block Diagram
Output Derating VS Input Voltage
Mechanical Specification
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html