BEMKO SES04WH Infrared Motion Sensor Instruction Manual
- June 15, 2024
- BEMKO
Table of Contents
BEMKO SES04WH Infrared Motion Sensor
Product Information
Specifications
- Brand: Bemko Sp. z o. o.
- Model: SES04WH
- Power Output: 300W – 1200W
- Features: Infrared detector, energy-saving, wide functionality
Product Usage Instructions
Installation
- Choose a suitable location for the product where it has a clear view of the area to be monitored.
- Ensure that the power supply is turned off before proceeding with installation.
- Mount the product securely using the provided screws or mounting brackets.
- Connect the product to a power source using the supplied power cable.
- Turn on the power supply.
Functionality
The product is designed to automatically activate the connected load upon detecting motion in its detection field. It utilizes infrared radiation to detect movement and can activate devices with a power rating of at least 1W. Additionally, the product features a light-sensitive element that allows it to identify the time of day and adjust its operating characteristics according to the user’s individual preferences.
Operation
- Ensure that the power supply is turned on.
- Adjust the sensitivity and range settings using the provided controls, if necessary.
- The product will activate the connected load when motion is detected within its detection field.
- The connected load will remain active for a predetermined period of time, adjustable using the product’s timer settings.
- After the set time period, the product will automatically deactivate the connected load.
The product adopts good sensitivity detector and integrated circuit. It gathers automatism, convenience, safety, saving-energy and practical functions. It utilizes the infrared energy from human as control-signal source and it can start the load at once when one enters detection field. It can identify day and night automatically. It is easy to install and used widely.
SPECIFICATION
- Power Source: 230V
- Power Frequency: 50Hz
- Time Delay: Min.10sec 3sec, Max.15min 2min
- Rated Load: Max. 1200W ; 300W + LED
- Installation Height: 2.2-4m
- Detection Moving Speed: 0.6-1.5m/s
- Detection Range: 360
- Detection Distance: Ø6m max(<24℃℃)
- Ambient Light: <3-2000LUX (adjustable)
- Working Temperature: -20~+40
- Working Humidity: <93%RH
- Power Consumption: approx 0.5W
FUNCTION
- Can identify day and night: The consumer can adjust working state in different ambient light. It can work in the daytime and at night when it is adjusted on the “sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on the “3” position (min). As for the adjustment pattern, please refer to the testing pattern.
- Time-Delay is added continually: When it receives the second induction signals within the first induction, it will restart to time from the moment
INSTALLATION ADVICE
As the detector responds to changes in temperature, avoid the following situations:
- Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
- Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
- Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
CONNECTION
Warning. Danger of death through electric shock!
-
Must be installed by professional electrician.
-
Disconnect power source.
-
Cover or shied any adjacent live components.
-
Ensure device cannot be switched on.
-
Check power supply is disconnected.
-
Unload the transparent vinyl cover which is at the bottom of the sensor.
-
Loose the screws in the connection terminal, and then connect the power to connection terminal of sensor according to connection-wire diagram.
-
Install back the transparent vinyl cover into the original location.
-
Fold the metal spring of the sensor upwards, until they are in “I” position with sensor, and then put the sensor into the hole or installation box which is on the ceiling and has the similar size with the sensor. Releasing the spring, the sensor will be set in this installation position.
-
After finishing installing, turn on the power and then test it.
CONNECTION-WIRE DIAGRAM:
TEST:
- Turn the TIME knob anti-clockwise on the minimum(10s).Turn the LUX knob clockwise on the maximum (sun).
- Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will turn on.
While there is no another induction signal any more, the load should stop working within 10sec±3sec and the lamp would turn off.
- Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the sensor would not work and the lamp stop working too. If you cover the detection window with the opaque objects (towel etc), the sensor would work .Under no induction signal condition, the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work! If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
- The load do not work:
- a. Please check if the connection-wiring of power and load is correct.
- . Please check if the load is good.
- c. Please check if the working light sets correspond to ambient light.
- The sensitivity is poor:
- a. Please check if there has any hindrance in front of the detection window to affect to receive the signal.
- b. Please check if the ambient temperature is too high.
- c.Please check if the induction signal source is in the detection fields.
- d.Please check if the installation height corresponds to the height showed in theinstruction.
- e.Please check if the moving orientation is correct.
- The sensor can not shut off the load automatically:
- a.Please check if there is continual signal in the detection field.
- b.Please check if the time delay is the longest.
- c.Please check if the power corresponds to the instruction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>