BEMKO SES04WH-A Infrared Motion Sensor User Manual

October 28, 2023
BEMKO

SES04WH-A Infrared Motion Sensor
User Manual
Infrared motion sensor

SPECIFICATION

Power source 230V~ 50Hz Detection range 360º
Rated load max 800W
400W Time delay min: 10s±3s

max:15min±2min
Power consumption| Pon: <0.5W| Working temperature| -20~+40°C
Standby power| Psb: <0.5W| Working humidity| <93%RH
Detection distance| Ø8m max (<24°C)| Installation height| max: 2.2m~4m
Ambient light| 3-2000LUX (adjustable)| Detection moving speed| 0.6~1.5m/s

FUNCTION

  • Can identify day and night: The consumer can adjust working state in different ambient light. It can work in the daytime and at night when it is adjusted on the “sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on the “3” position (min). As for the adjustment pattern, please refer to the testing pattern.
  • Time-Delay is added continually: When it receives the second induction signals within the first induction, it will restart to time from the moment.

INSTALLATION NOTES

  • Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
  • Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
  • Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.BEMKO SES04WH A Infrared Motion Sensor - INSTALLATION

CONNECTION

WARNING
Warning! Danger of death through electric shock!
– must be installed by professional electrician
– disconnect power source
– cover or shied any adjacent live components
– check power supply is disconnected

BEMKO SES04WH A Infrared Motion Sensor - CONNECTION

  • Unload the transparent vinyl cover which is at the bottom of the sensor.
  • Loose the screws in the connection terminal, and then connect the power to connection terminal of sensor according to connection-wire diagram.
  • Install back the transparent vinyl cover into the original location.
  • Fold the metal spring of the sensor upwards, until they are in “I” position with sensor, and then put the sensor into the hole or installation box which is on the ceiling and has the similar size with the sensor. Releasing the spring, the sensor will be set in this installation position.
  • After finishing installing, turn on the power and then test it.BEMKO SES04WH A Infrared Motion Sensor - finishing installing

TEST

  • Turn the TIME knob anti-clockwise on the minimum(10s).Turn the LUX knob clockwise on the maximum (sun).
  • Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will turn on. While there is no another induction signal any more, the load should stop working within 10sec±3sec and the lamp would turn off.
  • Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the sensor would not work and the lamp stop working too. If you cover the detection window with the opaque objects (towel etc), the sensor would work. Under no induction signal condition, the sensor should stop working within 10sec±3sec.

NOTE: When testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work! If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.

BEMKO SES04WH A Infrared Motion Sensor - distance

MOST COMMON PROBLEMS AND SOLVING WAYS

The load do not work:

  1. Please check if the connection-wiring of power and load is correct.
  2. Please check if the load is good.
  3. Please check if the working light sets correspond to ambient light.

The sensitivity is poor:

  1. Please check if there has any hindrance in front of the detection window to affect to receive the signal.
  2. Please check if the ambient temperature is too high.
  3. Please check if the induction signal source is in the detection fields
  4. Please check if the installation height corresponds to the height showed in the instruction.
  5. Please check if the moving orientation is correct.

The sensor can not shut off the load automatically:

  1. Please check if there is continual signal in the detection field.
  2. Please check if the time delay is the longest.
  3. Please check if the power corresponds to the instruction.

Waste electrical products should not be disposed with household waste. Please recycle where facilities exist. Check with Your Local Authorityor retailer for recycling advice.