VORTICE CA MD RF Commercial Ventilation Centrifugal Fans Instruction Manual

June 15, 2024
VORTICE

VORTICE CA MD RF Commercial Ventilation Centrifugal Fans Instruction Manual
VORTICE CA MD RF Commercial Ventilation Centrifugal
Fans

Description and use

The unit you have purchased is a centrifugal roof fan for free extraction or in ventilation ducts.

IMPORTANT: The unit is able to develop 3 ventilation speeds, as it is already equipped with suitable condensers. Operating speed control is designated to pairing with an appropriate 3-speed selector. For further information regarding the control device, see the “Wiring diagrams” paragraph.

  • These appliances are designed for use in residential and commercial properties.

Warning: this symbol indicates that care must be taken to avoid injury to the user

Accessories

CODE MODEL
22750 CA-G 100
22755 CA-G 125
22760 CA-G 150
22762 CA-G 160
22765 CA-G 200
22770 CA-G 250
22775 CAG 315

Safety

  • Always use the product for the purpose it was intended, as specified in this booklet.
  • After removing the product from its packaging, ensure that it is not damaged. If in doubt please contact a Vortice authorised Technical Assistance Centre immediately. Never leave packaging parts within reach of children or disabled persons.
  • The use of any electric device requires compliance with a few fundamental rules, including:
    • Never touch it with wet or humid hands.
    • Never touch it when barefoot.
    • Do not allow use by unsupervised children or disabled persons.
  • Do not use the unit in the presence of flammable substances or vapours such as alcohol, insecticides, gasoline, etc.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • Precautions must be taken to prevent gas coming from the gas flue pipe or from other fuel combustion units from entering into the room.
  • Products installed without a protective device for moving parts must be installed at a height greater than 2.3 m above the floor level.
  • Units equipped with manual reset thermal breaker device
    In order to avoid any danger of accidental reset of the thermal breaker device, units must not be powered by an external switch device such as a timer, or must not be connected to a circuit that is regularly powered or disconnected from power utilities

Caution: this symbol indicates that care must be taken to avoid damaging the appliance

  • Do not make changes of any kind to the unit.

  • Do not leave the device exposed to adverse weather conditions (rain, sun, etc.).

  • Do not rest objects on the device.

  • Periodically check device conditions. If imperfections are noted, do not use the unit and immediately contact a Vortice authorised Technical Assistance Centre.

  • Promptly contact a Vortice authorised Assistance Centre in the event of unit malfunction and/or failure and request the use of original Vortice spare parts for any repairs.

  • If the unit falls or receives a strong blow, immediately have it inspected at a Vortice authorised Technical Assistance Centre.

  • Only connect the device to the mains supply/ electrical outlet if plant/outlet capacity is suitable for its maximum power. If otherwise, immediately seek assistance from a professionally qualified person.

  • Switch off the main switch on the system when: a) a malfunction is detected, b) you decide to perform external cleaning maintenance, c) when you decide not to use the device for prolonged periods.

  • It is essential to ensure that sufficient air re-enters the room, in order to guarantee product operation. If a combustion-powered, non air-tight device is installed in the room (water heater, methane stove, etc.), please ensure that air re-entry also guarantees the perfect combustion of said device.

  • The unit cannot be used as an activator for water heaters, stoves, etc. nor should it discharge into hot air ducts.

  • The device must suction in a single duct (used by this product only), or directly outside.

  • Never cover the two intake grilles and the device return duct, to ensure optimal air passage.

  • The maximum temperature for product operation is:
    = 55°C for models 150-160-200-250-315
    = 50°C for models 100-125-150Q

  • An omnipolar switch with a contact opening distance of 3 mm or higher should be provided for installation, enabling complete disconnection under overvoltage category III conditions.

  • Products equipped with singlephase wiring (M) engines ALWAYS require connection to 220-240V (or only 230V where required) single-phase lines. Any kind of modification shall be considered as product tampering and shall nullify the relative warranty.

  • No specific adjustment is necessary as the devices operate at nominal frequencies without a preliminary setting.

Thermal protection devices:

Manual reset thermal protector
The following models are equipped with a manual reset thermal protector
If the thermal protector is triggered, please contact qualified personnel or Vortice authorised

Technical Assistance Centre.
If the problem persists after the reset operation, check the electrical system to which the unit is connected. In this case, please contact a Vortice authorised Technical Assistance Centre or professionally qualified personnel.

  • The electrical specifications correspond to the ones on the data label A (fig.A)
    data label

Typical applications

The images shown refer to typical applications for this product.
In particular, in Figure 1, it is possible to check the correct orientation of the product from duct:
A= intake
B= delivery

See Figures 1-5;
Typical applications
Typical applications
Typical applications

Installation

The images shown are purely indicative. Their purpose is to illustrate the main assembly steps for the entire range.

IMPORTANT: See the “Wiring Diagrams” paragraph to check the 3 ventilation speeds.

IMPORTANT
If the unit does not have piping connected to the suction point (free suction) and it is installed at a height lower than 2.3 m, assembly of the protection grille – suction side (fig. 6-7) is required.

See Figures 6-12.
Installation
Installation
Installation
Installation

Wiring diagrams

See Figure 13
Wiring diagrams

Connection with the optional device upon request is foreseen to check ventilation speeds (device not supplied in packaging):

  • 13A) Vortice 3-speed selector Code 12866 o 1289.
    Wiring diagrams

IMPORTANT
Vortice guarantees correct product operation and control only when paired with the Vortice 3-speed selector (Code 12.866-12891).

Other types of connection
Alternatively, other connection diagrams are available, associated to different control modes (devices provided by the installer).

Connection alternative for new installation

  • 13B) max
    Wiring diagrams

  • 13C) med
    Wiring diagrams

  • 13D) min
    Wiring diagrams

Machine replacement on existing system
Connection without modifications to the electrical system: the same switches as on the existing system will be used.

Maintenance / Cleaning

Fig 14-17.
Cleaning
Cleaning

Disposal

This product complies with Directive 2012/19/EU on the management of waste electrical and electronic equipment (WEEE).

The crossed-out wheeled bin symbol on the appliance indicates that, at the end of its life, the product should not be discarded together with household waste but must be taken to a separate collection point for electrical and electronic equipment. This will avoid negative effects on the environment and health, and will encourage correct treatment, disposal and recycling of the materials from which the product is made.

Contact the municipal authority for the location of this type of facility. Alternatively, the distributor is obliged to take back the appliance to be disposed of free of charge in exchange for the purchase of an equivalent appliance.

VORTICE S.p.A. reserves the right to make improvements to products at any time and without prior notice.

VORTICE GROUP COMPANIES

VORTICE S.p.A.
Strada Cerca, 2 – frazione di Zoate
20067 – Tribiano (MI)
Tel. +39 02-90.69.91

ITALY
vortice.com
postvendita@vortice-italy.com

VORTICE INDUSTRIAL Srl
Via B. Brugnoli, 3
37063 – Isola della Scala (VR)
Tel. +39 045 6631042

ITALY
vorticeindustrial.com
info@vorticeindustrial.com

VORTICE VENTILATION SYSTEM (CHANGZHOU) CO.LTD
Building 19, No.388 West Huanghe Road, Xinbei District,
Changzhou, Jiangsu Province CAP:213000

CHINA
vortice-china.com
vortice@vortice-china.com

VORTICE LIMITED
Beeches House-Eastern Avenue
Burton on Trent – DE 13 0BB
Tel. +44 1283-49.29.49

UNITED KINGDOM
vortice.ltd.uk
sales@vortice.ltd.uk

VORTICE LATAM S.A.
Bodega #6
Zona Franca Este Alajuela – Alajuela 20101
Tel. (+506) 2201 6934

COSTA RICA
vortice-latam.com
info@vortice-latam.com

CASALS VENTILACIÓN INDUSTRIAL IND., S.L
Ctra. Camprodon, s/n
17860 – Sant Joan de les Abadesses (Girona)

SPAIN
casals.com
ventilacion@casals.com

VORTICE logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals