ELKAY LZS8WSSP-W1 LZ Series Bottle Filling Stations and Coolers User Manual
- June 15, 2024
- ELKAY
Table of Contents
- ELKAY LZS8WSSP-W1 LZ Series Bottle Filling Stations and Coolers
- INSTALLATION & USE MANUAL
- HANGER BRACKET INSTALLATION
- Instructions For Replacing Filters
- 115V Refrigerated Wiring Diagram with Alpha/Numeric Display Connected
- OPERATION OF QUICK CONNECT FITTINGS
- WATERSENTRY® Filter Detail
- Service Instructions
- Cleaning
- Plastic Components
- Stream Height Adjustment
- Temperature Control
- Stream Height Adjustment
- Pictured is unit only without bottle filler.
- INDUSTRY CANADA STATEMENT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELKAY LZS8WSSP-W1 LZ Series Bottle Filling Stations and Coolers
Specifications
- Model : ENLZS8WS1G- W1
- Patent : zurn-elkay.com/patents
- Page : 1
- Dimensions :
- Height : 28 13/16″ (731mm)
- Width : 51 9/16″ (1310mm)
- Depth : 19″ (483mm)
Installation
- Locate the recommended water supply location (A) and connect a 3/8″ O.D. unplanted copper tube to the stub with a shut-off valve.
- Locate the recommended location for the waste outlet (B) and connect a 1-1/4″ O.D. drain stub.
- Ensure proper ventilation by maintaining a minimum clearance of 6″ (152mm) between the cabinet louvers and the wall (E).
- Use the provided bolt holes (F) to fasten the unit securely to the wall.
Hanger Bracket Installation
- Remove the hanger bracket fastened to the back of the cooler by removing the screw.
- Mount the hanger bracket securely to the wall using all six (6) provided mounting holes.
- Maintain a distance of 5-7/8″ (150mm) from the wall to the centerline of the trap for proper fit.
Installation of Cooler
- Connect the water supply line to the recommended location (A).
- Connect the drain line to the trap (C) and tighten securely.
- If needed, cut the drain and reassemble, checking for leaks after.
Enhanced
INSTALLATION & USE MANUAL
LZ ™ Series Bottle Filling Stations & Coolers
CONNECTED READY
Patent zurn-elkay.com/patents
WARNING : Cancer and Reproductive Harm –
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDREN’S ADA COOLER
LEGEND/LEYENDA/LÉGENDE
- A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
- B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN STUB 2 IN. OUT FROM WALL
- C = 1-1/4″ TRAP NOT FURNISHED
- D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
- E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL. F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
NOTE: IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS.
ENLZS8WS1G- W1
NOTE
- Ensure that there are no plumbing or external objects below the wrapper in the specified dimension. This minimum distance is required for the wrapper to swing out.
- To access internal components, remove security screw and gently move wrapper down and rotate. When servicing is completed and once wrapper is in place prior to engaging security screw with frame threads, ensure thru hole is aligned with frame threads. Ensure screw is angled relative to the ground and perpendicular to wrapper surface prior to engagement. Hand tighten prior to using hand tool to avoid cross-threading. DO NOT USE POWER TOOL TO TIGHTEN. DO NOT OVERTIGHTEN.
- Removing the wrapper from the pivoting bracket when servicing the unit is recommended. The wrapper may be left in place for quick serviceability.
- CAUTION : DO NOT LEAN ON WRAPPER.
- CAUTION : WRAPPER DROPS AND SWINGS WHEN SECURITY SCREWS ARE REMOVED.
HANGER BRACKET INSTALLATION
-
Remove hanger bracket fastened to back of cooler by removing one (1) screw.
-
Mount the hanger bracket as shown in Figure 1 (Pg. 2).
NOTE : Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes.
IMPORTANT : 5-7/8 in. (150mm) dimension from wall to centerline of trap must be maintained for proper fit.
INSTALLATION OF COOLER -
Hang the cooler on the hanger bracket. Be certain hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 1 (Pg. 2).
-
Remove the two front screws holding the lower front panel at the bottom of the cooler (see Fig 7, Pg. 6). Rotate the front panel down (see Fig B, Pg. 3) and remove.
-
Secure cooler frame to wall by installing (2) screws and washers (not supplied). (See Fig. 2, Pg. 4). Make sure the screws engage in a structural member.
-
Connect the supply water to the filter inlet tube.
-
Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap. Assemble the slip nut and gasket to the trap and tighten securely.
IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.
BOTTLE FILLER INSTALLATION -
Remove two (2) mounting screws with 5/32″ Allen wrench holding bottle filler to wall mounting plate (See Fig.8, Pg. 5). Note do not discard mounting screws, they will be needed to secure bottle filler to wall mounting plate.
-
Remove wall mounting plate from Bottle Filler (see Fig 8, Pg. 5). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side to side with the basin. Mark the six (6) mounting holes with a pencil. Place tape over wiring harnes conection on top of cooler to prevent debris from falling into Connection.
-
Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate support.
-
Install wall mounting plate to wall using six (6) 7/16″ obround mounting holes (mounting bolts not included) (See Fig.8, Pg. 5). Use appropriate fasteners for your wall type.
-
Install gasket on bottom of bottle filler tower with gasket support bracket & (2) screws. (See Fig. 4, Pg. 4).
-
Route 3/8” tubing through the opening in the bottle filler gasket and plug into bulkhead fitting in basin. Route the wiring harness through the gasket and plug into the connector on the top of the basin.
-
Place bottle filler on four (4) hooks on the mounting plate installed on wall. Make sure round boss in gasket fits in hole of basin. (See Fig. 8, Pg. 5).
-
Plug electrical cord into outlet on wall.
-
Remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. Ensure that blue label can be read when filter is installed. (See Fig. 11, Pg. 7).
-
urn water supply on and inspect for leaks. In both cooler and bottle filler. Fix all leaks before continuing.
-
Once cooler and bottle filter has been inspected for leaks and any leaks found corrected.
-
Reinstall two mounting screws from first step (See Fig. 8, Pg. 5). Caution, do not over tighten screws.
-
Once power is applied to the cooler the GREEN LED light will illuminate on the bottle filler showing good filter status along with the LCD Bottle Counter.
-
Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first initial dispenses might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line.
-
Once unit tests out, install Lower Panel back on water cooler(s). Units are now ready for use.
Instructions For Replacing Filters
- Remove the (2) screws (see Fig 7, Pg. 6) and rotate the front panel down (see Fig B, Pg. 3).
- Turn off water supply; dispense water to relieve pressure.
- Remove power by unplugging cooler.
- Turn used filter counterclockwise 1/4 turn to remove from filter head.
- Remove cap from new filter and use to seal used filter.
- Insert new filter into existing filter head and turn fully clockwise. Make sure you can read the label on the front of the filter once it is installed. (See Fig.11, Pg. 7).
- Plug in unit to restore power.
- Turn on water supply and run a minimum of two gallons of water through the filter to purge air any fine carbon particles from filter. Also run water through bottle filler Note: Filter status light will automatically reset once new filter is installed.
Instructions To Access Programming Button
- Remove lower cover on refrigerated unit by removing (2) screws (see Fig 7, Pg. 5) and rotating the front panel down (see Fig B, Pg. 3).
- Button is located in lower right corner of unit (See Fig. A, Pg. 3).
ENLZS8WS1G- W1
Lay gasket along back of bottle filler mounting plate. Align BF and lay on cooler basin.
ENLZS8WS1G – W1
115V Refrigerated Wiring Diagram with Alpha/Numeric Display Connected
Ready – Enhanced Bottle Filler
OPERATION OF QUICK CONNECT FITTINGS
ENLZS8WS1G – W1
WATERSENTRY® Filter Detail
Service Instructions
Lower and Upper Shroud
- To access the refrigeration system and plumbing connections, Remove two (2) screws from front of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components
- located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
Bubbler
- To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be reached through the access panel on the underside of the upper shroud. Remove the access panel by removing the retaining screw. To remove
- the bubbler, loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel and retaining screw.
Switches Behind the Push Bar
- The regulator in an EZ cooler is always held fully open by the use of a single regulator nut (See Item 9, Fig. 14). Water is not dispensed until the pushbar is depressed to activate a switch which then opens a solenoid valve.
- To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall side pushbars, the front of the pushbar is inserted first. While keeping the switch depressed, snap the rear of the pushbar into position.
Cleaning
- Stainless Steel
- General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
- Steel soap pads should never be used; particles can adhere to a stainless steel basin surface and will eventually rust.
- Light scratches are normal for stainless steel basins; over time they will blend into the uniform finish pattern.
Plastic Components
- General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
- Wiping the surface clean to remove debris or build up will not hurt the antimicrobial properties.
Factory set at 50°F (+/- 5°F) under normal conditions. For temperature adjustments, refer to sticker on left side of top bar.
Stream Height Adjustment
VIEW OF UNDERSIDE OF BASIN SHROUD
Temperature Control
Factory set at 50°F (+/- 5°F) under normal conditions. For temperature adjustments, refer to sticker on left side of top bar.
Stream Height Adjustment
VIEW OF UNDERSIDE OF BASIN SHROUD
Programming Instruction
Depress Button for 3 seconds to activate main menu – release
Cycles thru main menu items 2 seconds each for 2 cycles then exits menu
unless selected
Cycles thru sub menu items 2 seconds each for 2 cycles then returns to main
menu unless selected
Selections are saved when the menu is exited
Top leve l| Action| Sub Menu 1| Action|
Sub Menu/action| Action| Sub Menu/ action| Action|
Sub Menu/ action| Notes| End Action
Info| Momentary| Scrolls through all the settings on unit| | | | | | | |
Returns to Main Menu
Info| Momentary| Flashes error code| | | | | | | | Returns to Main Menu
Set time| Momentary| | | | | | | | | Drops to next level when selected
| Day (Sunday-Saturday| Momentary| | | | | | Use push button to select the day
on the display| Drops to next level when selected
| AM/PM| Momentary| | | | | | Use push button to select AM or PM| Drops to
next level when selected
| Hour (12 hour)| Momentary| | | | | | Use push button to select Hour| Drops
to next level when selected
| Min 0-69 in 5 minute increments| Momentary| | | | | | Use push button to
select closest minute| Returns to Main Menu
Filter| Momentary| | | | | | | | | Drops to next level when selected
| No| Momentary| Turn off filter status and erros| | | | | No Filter unit –
Error codes related to filter status
turned off
| Returns to Main Menu
| Yes| Momentary| Default setting – Turn on filter status and errors| | | | |
Filter status has default ON / Default has read write to filter, LED status
display, filter error capability| Returns to Main Menu
Refrig| Momentary| | | | | | | | | Drops to next level when selected
| No| Momentary| Turns off power to E/S relay sets bottle fill time to 1.5gpm|
| | | | Refrigeration off| Returns to Main Menu
| Yes| Momentary| Default setting – Turns on power to E/S relay – sets time to
1.1gpm| | | | | Refrigeration on| Returns to Main Menu
Range| Momentary| | | | | | | | The lower the number, the closer to the sensor
the
bottle needs to be to activate
| Drops to next level when selected
| 1-10| Momentary| Default setting 5 – Adjusts distance from sensor the bottle
needs
to be before turning before turning on or off the bottle filler
| | | | | | Returns to Main Menu
B-Light| Momentary| | | | | | | | The settings are for the brightness of the
display and night light| Drops to next level when selected
| 25%| Momentary| | | | | | | Returns to Main Menu
| 50%| Momentary| | | | | | | Returns to Main Menu
| 75%| Momentary| Default Setting| | | | | | Returns to Main Menu
| 100%| Momentary| | | | | | | Returns to Main Menu
EnerSave| Momentary| | | | | | | | | Drops to next level when selected
| Off| Momentary| Default Setting| | | | | | Returns to Main Menu
| On| Momentary| Set Energy Save Schedule| | | | | | Drops to next level when
selected
| | | | | Select Weekday| | | | Drops to next level when selected
| | | | | | Momentary| Select time on| 24 hours – 1-12AM and 1-12PM| Drops to
next level when selected
| | | | | | Momentary| Select time off| 24 hours – 1-12AM and 1-12PM| Drops to
next level when selected
| | | | | Select Weekend| | | | Drops to next level when selected
| | | | | | Momentary| Select time on| 24 hours – 1-12AM and 1-12PM| Drops to
next level when selected
| | | | | | Momentary| Select time off| 24 hours – 1-12AM and 1-12PM| Returns
to Main Menu
Enhanced EZH2O Error Codes
Error Code | Error Description | Corrective Action |
---|---|---|
Bottle filler area obstructed |
- Remove obstruction.
- Clean lens on IR sensor
- Unplug unit for at least 30 seconds and restart
- If error repeats, replace IR sensor
E013| Missing or Incompatible Filter|
- Check that filter is installed correctly (label facing forward, white tag faing back)
- Unplug unit for at least 30 seconds and restart
- Replace filter
- Replace filter head assembly with repair kit
- If error repeats, contact certified service professional
E013 & E014| Missing NFC Board|
- Unplug unit for at least 30 seconds and restart
- Verify cable connector is plugged into NFC board on filter head assembly
- Replace filter head assembly with repair kit
- If error repeats, contact certified service professional
Pictured is unit only without bottle filler.
Note : Danger! Electrical shock hazard. Disconnect power before servicing unit.
115V PARTS LIST | ATTENTION: |
---|---|
ITEM NO. | PART NO. |
number is before 190424189, please refer to archived**
documents section of Elkay.com for the most accurate parts list. (www.elkay.com/archived-documents))
1| 28401C| Hanger Bracket
2| 0000001337| Basin – Stainless Steel|
3| 36216C| Wiring – Front/Side Push Bar|
*4| 36322C| Compr – Service Pak 115V EMIS70HHR|
5| 56092C| Tube – Poly (72”)|
6| 56229C| Assy – Shroud – Upper (Front Side Push)|
7| 66703C| Drier|
8| 1000001877| Kit – Drain Replacement (Bottle Filler) (Bracket, Tube,
Fitting, Clamp)|
9| 1000004564| Kit – Regular/Holder/Nut|
10| 1000004572| Kit – Solenoid Valve/Regulator Assembly|
11| 56073C| Kit – Flexi Bubbler/“O”-Ring/Nut|
12| 98734C| Kit – Pushbar (Front/Side) EZS TL|
13| 1000001600| Kit – Pushbar (Front Only)|
14| 1000004568| Power Cord|
15| 98775C| Kit – Fan Motor/Blade/Screws/Nut|
16| 98776C| Kit – Condenser/Drier/Wire Ties|
17| 98777C| Kit – Compr Mtg Hdwe/Grommets/Clips/Studs|
18| 98778C| Kit – Heatx/Drier|
19| 98898C| Kit – Hardware|
20| 0000000238| Kit – 115V Electricals (Relay, Overload, Cover)|
21| 98724C| Kit – Evap. Replacement|
22| 1000001812| Kit – Bottle Filler Drain|
23| 56237C| Shroud|
24| 1000001602| Kit – 75583C Elbow 5/16″ x 1/4″ (3 Pack)|
25| 1000004559| Wire Assy – Jumper|
26| 56213C| Access Panel|
27| 1000004547| Harness – Cooler|
28| 1000004550| Wire – 6” Jumper|
29| 98773C| Kit – Cold Control|
NS| 2000001211| Wrapper Stainless Steel|
*INCLUDES R ELAY & OVERLOAD. IF
NS = Not Shown
UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NS = Not Shown NOTE: All correspondence pertaining to any of the
above water coolers or orders for repair parts MUST
include Model No. and Serial No. of cooler, name and part number of replacement part.
Register in plumbSMART
-
Install Zorn Gateway per the Gateway Instructions Manual (Required & Sold Separately)
-
Request plumbSMART Administrator Account at 844-987-6737
-
Zorn creates your Enterprise Account for you! (You will be required to identify your building location, number of floors, and number of rooms.)
-
Log in to plumbsmart.zurn.com
-
Register each Connected Product in plumbSMART (Watch How-To Videos to Get Started. Located in the support section inside the portal.
Note: Refer plumbSMART Registration ID Label provided with Connected Product. -
Now, Relax. You’re Connected.
FCC COMPLIANCE STATEMENT
CAUTION : Changes or modifications not expressly approved could void your authority to use this equipment
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device shall be used in such a manner that the potential for human contact normal operation is minimized. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
PRINTED IN U.S.A. REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD • DOWNERS GROVE, IL 60515 • 630.574.8484 • www.elkay.com
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
- FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
- PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAME AL 1.800.834.4816
- POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.834.4816
- REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
- NÚMERO GRATIS DE SERVICIO 1.800.260.6640
- INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1.800.260.6640
ELKAY MANUFACTURING Co.
1333 BUTTERFLIED ROAD SUITE 200 D
OWNERS GROVE, IL 60515 USA – • 630.574.8484 •
www.elkay.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>