MEAN WELL GST220A series 220W AC-DC Reliable Green Industrial Adaptor Owner’s Manual

June 15, 2024
MEAN WELL

MEAN WELL GST220A series 220W AC-DC Reliable Green Industrial Adaptor

Product Information

Specifications

  • Model: GST220A series
  • Power: 220W
  • Input: Universal AC input / Full range
  • Output: 3 pole AC inlet IEC320-C14, Class power unit
  • No load power consumption: 0.91 / 230VAC, PF>0.98 / 115VAC at full load
  • Input Efficiency (Typ.): 90%
  • AC Current (Typ.): 4A / 115VAC, 2A / 230VAC
  • Inrush Current (max.): Cold start 95A / 115VAC, 120A / 230VAC
  • Leakage Current (max.): 0.75mA / 240VAC
  • Overload Protection: 105 ~ 135% rated output power, Hiccup mode, recovers automatically after fault condition is removed
  • Over Voltage Protection: 105 ~ 135% rated output voltage, Hiccup mode @ 10% load
  • Over Temperature Protection: Shut down o/p voltage, recovers automatically after temperature goes down, -30 ~ +70 (Refer to Derating Curve)
  • Working Humidity: 20% ~ 90% RH non-condensing
  • Storage Temperature, Humidity: -40 ~ +85, 10 ~ 95% RH non-condensing
  • Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
  • Withstand Voltage: I/P-O/P: 3KVAC, I/P-FG: 2KVAC, O/P-FG: SHORT
  • Isolation Resistance: I/P-O/P: 100M Ohms / 500VDC / 25/70% RH
  • EMC Emission: Conducted emission, Radiated emission, Harmonic current, Voltage flicker
  • EMC Immunity: ESD, RF field susceptibility, EFT bursts, Surge susceptibility, Conducted susceptibility, Magnetic field immunity, Voltage dips, interruption
  • MTBF: 2006.1K hrs min. Telcordia SR-332 (Bellcore); 209.4K hrs min.
  • Dimension: 2108546mm (LWH)
  • Packing: 1.1Kg; 12pcs/14.2Kg/0.81CUFT
  • Plug Connector Cable: See page 4~5; Other type available by customer requested

Product Usage Instructions

Step 1: Installation

  1. Ensure that the power source is compatible with the input requirements of the adaptor.
  2. Connect the three-pole AC inlet IEC320-C14 to the power source.
  3. Make sure the adaptor is properly grounded to ensure safety.

Step 2: Connecting Devices

  1. Identify the appropriate output voltage required for your device.
  2. Connect the output cable of the adaptor to your device.
  3. Ensure a secure connection between the adaptor and the device.

Step 3: Powering On

  1. Turn on the power source.
  2. Check if the adaptor is receiving power by looking for the LED indicator.

Step 4: Usage Tips

  • Avoid exposing the adaptor to extreme temperatures or humidity.
  • Do not overload the adaptor beyond its rated output power.
  • If an overload or overvoltage condition occurs, the adaptor will automatically enter hiccup mode and recover once the fault condition is removed.
  • Monitor the temperature of the adaptor during operation. If it exceeds the specified range, it will shut down and recover automatically when the temperature goes down.

Frequently Asked Questions (FAQ)

Q: What is the maximum power output of this adaptor?

A: The maximum power output of this adaptor is 220W.

Q: Can I use this adaptor with consumer electronic devices?

A: Yes, this adaptor is suitable for use with consumer electronic devices.

Q: What is the input voltage range for this adaptor?

A: This adaptor has a universal AC input range, which means it can accept a wide range of voltages.

Q: How do I know if the adaptor is receiving power?

A: The adaptor has an LED indicator that will light up when it is receiving power.

Q: What should I do if the adaptor becomes too hot during operation?

A: If the temperature of the adaptor exceeds the specified range, it will shut down automatically. Allow it to cool down before using it again.

Features

  • Global certificates
  • Universal AC input/ Full range
  • 3 pole AC inlet IEC320-C14,Class I power unit
  • Built-in active PFC function
  • No load power consumption<O.15W
  • Energy efficiency Level VI
  • Comply with EISA MEPS,
  • EU ErP and COC Version 5
  • Protections: Short circuit / Overload / Over voltage [Over temperature
  • Fanless design with -30-+700C working temperature
  • Fully enclosed plastic case
  • LED indicator for power on
  • Various DC plug quick adapter accessory available
  • (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DCplug.pdf)
  • • 3 years warranty

Applications

  • Consumer electronic devices
  • Telecommunication devices
  • Office facilities
  • Industrial equipments

GTIN CODE
MW Search: https://mvw.meanweIl.com/serviceGTIN.aspx

Description

GST220A is a highly reliable, 220W desktop-style single-output green adaptor series. This product is a class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 85VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With the efficiency up to 94.5% and the extremely low no-load power consumption below O. 15W, GST220A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS,Korea K-MEPS,EU ErP and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-O flame-retardant plastic case.GST220A is certified for the international safety regulations.

Model Encoding

MEAN-WELL-GST220A-series 220W-AC-DC-Reliable-Green-Industrial-Adaptor-
FIG-4

SPECIFICATION

ORDER NO.| GST220A12- R7B| GST220A15- R7B| GST220A20- R7B| GST220A24- R7B| GST220A36- R7B| GST220A48- R7B
---|---|---|---|---|---|---

OUTPUT

| SAFETY MODEL NO.| GST220A12| GST220A15| GST220A20| GST220A24| GST220A36| GST220A48
DC VOLTAGE| Note.2| 12V| 15V| 20V| 24V| 36V| 48V
RATED CURRENT| 15A| 13.4A| 11A| 9.2A| 6.1A| 4.6A
CURRENT RANGE| 0 ~ 15A| 0 ~ 13.4A| 0 ~ 11A| 0 ~ 9.2A| 0 ~ 6.1A| 0 ~ 4.6A
RATED POWER (max.)| 180W| 201W| 220W| 221W| 219.6W| 221W
RIPPLE & NOISE (max.) Note.3| 80mVp-p| 100mVp-p| 120mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±2.0%| ±2.0%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±2.0%| ±2.0%
SETUP, RISE TIME| Note.6| 2000ms, 50ms / 230VAC 2000ms, 50ms / 115VAC at full load
HOLD UP TIME (Typ.)| 20ms / 230VAC         20ms / 115VAC at full load

INPUT

| VOLTAGE RANGE **Note.7| 85 ~ 264VAC  120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.91 / 230VAC         PF>0.98 / 115VAC at full load
EFFICIENCY (Typ.)| 90%| 90%| 92%| 93.5%| 93%| 94.5%
AC CURRENT (Typ.)| 4A / 115VAC         2A / 230VAC
INRUSH CURRENT (max.)| Cold start 95A / 115VAC       120A / 230VAC
LEAKAGE CURRENT(max.)**| 0.75mA / 240VAC

PROTECTION

|

OVERLOAD

| 105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

| 105 ~ 135% rated output voltage
Protection type : Hiccup mode @ 10%load
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0~50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

(Note. 10)

|

SAFETY STANDARDS Note. 8

| UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1 ,

BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved

(UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1 for GST220A36-R7B)

WITHSTAND VOLTAGE| I/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG:SHORT
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

| Parameter| Standard| Test Level / Note

Conducted emission

| BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22

CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32

|

Class B

Radiated emission

| BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22

CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32

|

Class B

Harmonic current| BS EN/EN61000-3-2,GB9254| Class A
Voltage flicker| BS EN/EN61000-3-3| ——-

EMC IMMUNITY

| BS EN/EN55035
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 2, 3V/m
EFT bursts| BS EN/EN61000-4-4| Level 2, 1KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line , 2KV/Line-FG
Conducted susceptibility| BS EN/EN61000-4-6| Level 2, 3V
Magnetic field immunity| BS EN/EN61000-4-8| Level 2, 3A/m
Voltage dips , interruption| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods

OTHERS

| MTBF| 2006.1K hrs min.     Telcordia SR-332 (Bellcore) ; 209.4K hrs min.| MIL-HDBK-217F (25℃)|
DIMENSION| 2108546mm (LWH)
PACKING| 1.1Kg; 12pcs/14.2Kg/0.81CUFT

CONNECTOR

| PLUG| See page 4~5 ; Other type available by customer requested
CABLE| See page 4~5 ; Other type available by customer requested

NOTE

from Arrow

| 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.

2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.

3. Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1 f & 47μf capacμitor.

4. Tolerance: includes set up tolerance, line regulation, load regulation.

5. Line regulation is measured from low line to high line at rated load.

6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

7. Derating may be needed under low input voltage. Please check the derating curve for more details.

8. The demand for Malaysia safety is processed with the order no. GST220A -SIRIM by request. Please contact MEAN WELL for details.

9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

10.  The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

.com. File Name:GST220A-SPEC  2023-05-22

 |  |  |

Derating Curve

MEAN-WELL-GST220A-series 220W-AC-DC-Reliable-Green-Industrial-Adaptor-
FIG-5

Static Characteristics

Mechanical Specification

MEAN-WELL-GST220A-series 220W-AC-DC-Reliable-Green-Industrial-Adaptor-
FIG-7

DC output plug

Standard plug: R7B

MEAN-WELL-GST220A-series 220W-AC-DC-Reliable-Green-Industrial-Adaptor-
FIG-8

DC plug changeable through:

  1. Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
  2. Quick adapter accessory (sold separately without MOQ)
    Please refer to below table and online selection guide :

Example quick adapter accessory

MEAN-WELL-GST220A-series 220W-AC-DC-Reliable-Green-Industrial-Adaptor-
FIG-9

Optional DC plug: (Available in customized cable or quick adapter)

MEAN-WELL-GST220A-series 220W-AC-DC-Reliable-Green-Industrial-Adaptor-
FIG-10 MEAN-WELL-
GST220A-series 220W-AC-DC-Reliable-Green-Industrial-Adaptor-
FIG-11

Installation Manual

Please refer to : http://www.meanwell.com/manual.html.

Downloaded from Arrow.com.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals