DieseRC 5302G Channel Wireless Relay Remote Control Switch Instruction Manual
- June 15, 2024
- DieseRC
Table of Contents
DieseRC 5302G Channel Wireless Relay Remote Control Switch
Product Information
Specifications
- Working voltage: DC 5V~30V
- Input/output voltage: 1~250V
- Output Type: Passive output
- Quiescent Current: 97dbm
- Max current: Not specified
- RF frequency: Not specified
- Working temperature: Not specified
- Receiving Sensitivity: Not specified
- Amount of storage remote controls: 20 pieces
- Support encoding: 1527 Leaning code
- RF Operating mode: ASK superheterodyne wireless reception
- Receiving range: Open space is more than 50 meters
FAQ
- Q: What is the working voltage of the product?
- A: The working voltage of the product is DC 5V~30V.
- Q: How many remote controls can be stored in the product?
- A: The product can store up to 20 remote controls.
- Q: What is the maximum range for receiving signals?
- A: The product has a receiving range of more than 50 meters in open space.
- Q: How do I reset the receiver?
- A: To reset the receiver, press the learning button on the receiver eight times. The indicator LED on the receiver will flash several times and then light up.
Product Usage Instructions
Operating Modes
Momentary Mode
- Press and hold button A, relay 1 will turn on.
- Release button A, relay 1 will turn off.
Toggle Mode
- Press button A, relay 1 will turn on.
- Press button A again, relay 1 will turn off.
Latched Mode
- Press button A, relay 1 will turn on.
- Press button B, relay 2 will turn on and relay 1 will turn off simultaneously.
Programming Instructions
Momentary Mode
- Press the learning button on the receiver once. The indicator LED on the receiver will light down.
- Press button A on the remote transmitter. The indicator LED on the receiver will flash several times and then light down.
- Press button B on the remote transmitter. The indicator LED on the receiver will flash several times and then light up. Succeed.
Toggle Mode
- Press the learning button on the receiver twice. The indicator LED on the receiver will light down.
- Press button A on the remote transmitter. The indicator LED on the receiver will flash several times and then light down.
- Press button B on the remote transmitter. The indicator LED on the receiver will flash several times and then light up. Succeed.
Latched Mode
- Press the learning button on the receiver three times. The indicator LED on the receiver will light down.
- Press button A on the remote transmitter. The indicator LED on the receiver will flash several times and then light down.
- Press button B on the remote transmitter. The indicator LED on the receiver will flash several times and then light up. Succeed.
If there is any questions about the products,please contact us firstly. We will do our best to solve your problem. Thank you.
PRODUCT INFORMATION
TYPE—-5302G
Technical Data
Working voltage| DC 5V~30V
Input/output voltage| 1~250V
Output Type| Passive output
Quiescent Current| <5MA
Max current| 10A
RF frequency| 433MHz
Working temperature| -30~+80
Receiving Sensitivity| >97dbm
Amount of storage remote controls| 20 pieces
Support encoding| 1527 Leaning code
RF Operating mode| ASK superheterodyne wireless reception
Receiving range| Open space is more than 50 meters
Remote operating mode| Momentary Mode /Toggle Mode /Latched Mode
PRODUCT DETAIL
WIRING DIAGRAM
Warning
- Usually the receiver and transmitter have been paired with each other in factory. If not, you can reprogram by yourself.
- Reset before you want to change the operating mode.
- After reset, all the remote controls cannot work anymore.
- Replace the battery in time when the remote transmitter voltage is low. To get the stronger signal transmission.
- Slightly stretch the antenna on the receiver for better signal reception.
- The remote transmitter need to have 3 or more buttons, if you want to set up in latched mode.
- The output type is passive output / potential-free contacts.
Operating Mode
Momentary Mode
- Press and hold on button “A”, relay “1” will turn on;
- Release the button “A”, this relay “1” will turn off.
How to program
- Press the learning button (on the receiver) 1 time. The indicator LED on the receiver will light down;
- Press button “A” on the remote transmitter. The indicator LED on the receiver will flashing several times and then light down;
- Press button “B” on the remote transmitter. The indicator LED on the receiver will flashing several times and then light up. Succeed.
Toggle Mode
- Press button “A”, relay “1” will turn on;
- Press button “A” again, this relay “1” will turn off.
How to program
- Press the learning button (on the receiver) 2 times. The indicator LED on the receiver will light down;
- Press button “A” on the remote transmitter. The indicator LED on the receiver will flashing several times and then light down;
- Press button “B” on the remote transmitter. The indicator LED on the receiver will flashing several times and then light up. Succeed.
Latched mode
- Press button “A”, relay “1” will turn on;
- Press button “B”, relay “2” will turn on, at the same time relay “1” will turn off.
How to program
- Press the learning button (on the receiver) 3 times. The indicator LED on the receiver will light down;
- Press button “A” on the remote transmitter. The indicator LED on the receiver will flashing several times and then light down;
- Press button “B” on the remote transmitter. The indicator LED on the receiver will flashing several times and then light up. Succeed.
Reset
- Press the learning button (on the receiver) 8 times.
- The indicator LED on the receiver will flashing several times and then light up. Succeed.
Troubleshooting
If the receiver and transmitter cannot operate normally, try to solve the problem by follow the step below.
- Please check if batteries power is used up. The indicator LED on remote transmitter does not light up or is dimly lit.
- Please check if your receiver is wired correctly. It is important to make sure the wiring is correct.
- Reprogram the receiver and transmitter. Usually this can solve a lot of problem.
- If the problem still remains, please contact us in time. We will do our best to solve your problem. Email: “dieseelectronic@163.com” or WhatsApp: +86 13502278583
Work volts: DC 5V~30V
Max current: 10Amp
Contact
- Huizhou Wenqiao Electronic Technology Co., Ltd.
- Address: 1203, Building T19, Fangzhilonghuwan, Sanhuan South Road, Huicheng District, Huizhou City, Guangdong Province, China 516000
- WhatsApp: +86 13502278583 / +86 18138805271
- Email: dieseelectronic@163.com