PROGRAMMING
-
MODE BUTTON
This button cycles through each of the controller’s modes: ON, OFF, TIMER, AUTO (4 triggers), and ALARM (4 settings). Press and hold the mode button to return to the previous mode. -
UP / DOWN BUTTON
The up and down buttons adjust the setting of the mode that you are in. -
LEAF BUTTON
This turns the display off while programs run in the background. Hold for two seconds to lock or unlock the display. -
PROBE TEMP
Displays the current temperature that the corded sensor probe is measuring. Show “–” and alert if no probe is plugged in. -
CONTROLLER MODE
This area displays the mode that the controller is currently in. Press the Mode Button to cycle through all modes. -
ALERT ICONS
This area displays the alerts and statuses from the controller including alarms and screen lock. -
PROBE HUMIDITY
Display the current humidity that the corded sensor probe is measuring. Show “- -” and alert if no probe is plugged in. -
FAN SPEED
Display the current speed the fan is running at, or what speed it should be running at if no fans are plugged in. -
SETTING
Displays the value you have set for the current mode. Press the up or down button to change.
MODE SETTING
Press the Mode button to cycle through the controller’s available programming
modes and settings:
ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers), ALARM Settings (4
settings)
• ON MODE
In this mode, the fan will run continuously regardless of temperature or
humidity. The speed set in this mode will be the max speed the fan can reach
in AUTO Mode. Use this mode to set the fan’s maximum blowing strength, ranging
from 0-10.
• OFF MODE
In this mode. the fans will not run regardless of temperature or humidity.
While in this mode, pressing the up or down button will change the display’s
brightness. There are four settings for brightness, (Setting: 1/2/3/A3). On
setting A3, if the device is left unattended for 30 seconds, the display will
automatically dim its brightness back to setting 1. Holding up and down button
will change the display’s units F or C.
• TIMER MODE
In this mode, press the up or down button to set a time for the timer. The fan
will run at the speed set in ON Mode until the timer’s clock runs out, after
which the fan will stop running. The clock will begin counting down if no
buttons are pressed for 2 seconds. Leaving the timer mode while the countdown
is running will stop the clock unless you return to this mode.
• AUTO MODE: HIGH TEMP
In this mode, press the up or down button to set a high temperature trigger.
The fan will activate if the probe’s measured temperature exceeds the
temperature you have set in this mode. The activated fans will slowly increase
in speed until it reaches the speed set in ON Mode. If the measured
temperature falls below your set temperature, the fans will slowly decrease in
speed until the fans stop. You may also hold the up and down button
simultaneously to turn off this trigger, in which the digits under settings
will show OFF for off, hold the up and down button again to turn on this
trigger.
You may set this trigger below the low temperature trigger to create a range where the fan is active.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are in setting up the other AUTO Mode triggers
• AUTO MODE: LOW TEMP
In this mode, press the up or down button to set a low temperature trigger.
The fan will activate if the probe’s measured temperature falls below the
temperature you have set in this mode. The activated fan will slowly increase
in speed until it reaches the speed set in ON Mode. If the measured
temperature rises above your set temperature, the fan will slowly decrease in
speed until the fans stop. You may also hold the up and down button
simultaneously to turn off this trigger. after which the digits under settings
will show OFF, hold the up and down button again to turn on this trigger.
You may set this trigger above the high temperature trigger to create a range where the fan is active.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are in setting up the other AUTO Mode triggers.
• AUTO MODE: HIGH HUMID
In this mode, press the up or down button to set a high humidity trigger. The
fan will activate if the probe’s measured humidity exceeds the humidity you
have set in this mode. The activated fan will slowly increase in speed until
it reaches the speed set in ON Mode. Whenever the measured humidity falls
below your set humidity, the fan will slowly decrease in speed until the fans
stop. You may also hold the up and down button simultaneously to turn off this
trigger, after which the digits under settings will show OFF, hold the up and
down button again to turn on this trigger.
You may set this trigger below the low humidity trigger to create a range where the fan is active.
Note that this trigger can activate as long as you are in AUTO Mode even if you are in setting up the other AUTO Mode triggers.
• AUTO MODE: LOW HUMID
In this mode, press the up or down button to set a high humidity trigger. The
fan will activate if the probe’s measured humidity exceeds the humidity you
have set in this mode. The activated fan will slowly increase in speed until
it reaches the speed set in ON Mode. Whenever the measured humidity falls
below your set humidity, the fan will slowly decrease in speed until the fans
stop. You may also hold the up and down button simultaneously to turn off this
trigger, after which the digits under settings will show OFF, hold the up and
down button again to turn on this trigger.
You may set this trigger above the high humidity trigger to create a range where the fan is active.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are in setting up the other AUTO Mode triggers.
• ALARM SETTING: HIGH TEMP
In this mode, press the up and down button to set a high temperature alarm.
The alarm will activate if the probe’s measured temperature exceeds the
temperature you have set in this mode. When the alarm is triggered, the fan
will start spinning gradually to max speed regardless of your other settings.
You may also hold the up and down button simultaneously to turn off this
alarm, after which the digits under settings will show OFF, hold the up and
down button again to turn on this trigger.
You may set this alarm below the low temperature trigger to create an operating range.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
• ALARM SETTING: LOW TEMP
In this mode, press the up and down button to set a low temperature alarm. The
alarm will activate if the probe’s measured temperature falls below the
temperature you have set in this mode. When the alarm is triggered. the fan
will start spinning gradually to max speed regardless of your other settings.
You may also hold the up and down button simultaneously to turn off this
alarm, after which the digits under settings will show OFF, hold the up and
down button again to turn on this trigger.
You may set this alarm above the high temperature trigger to create an operating range.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
• ALARM SETTING: HIGH HUMID
In this mode, press the up and down button to set a high humidity alarm. The
alarm will activate if the probe’s measured humidity exceeds the humidity you
have set in this mode. When the alarm is triggered, the fan will start
spinning gradually to max speed regardless of your other settings. You may
also hold the up and down button simultaneously to turn off this alarm, after
which the digits under settings will show OFF, hold the up and down button
again to turn on this trigger.
You may set this alarm below the low humidity trigger to create an operating range.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
• ALARM SETTING: LOW HUMID
In this mode, press the up and down button to set a low humidity alarm. The
alarm will activate if the probe’s measured temperature falls below the
temperature you have set in this mode. When the alarm is triggered, the fan
will start spinning gradually to max speed regardless of your other settings.
You may also hold the up and down button simultaneously to turn off this
alarm, after which the digits under settings will show OFF, hold the up and
down button again to turn on this trigger.
You may set this alarm above the high humidity trigger to create an operating range.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
• FAHRENHEIT OR CELSIUS
To change to displayed units between Fahrenheit and Celsius, please set the
controller to OFF Mode, then hold the UP BUTTON and DOWN BUTTON simultaneously
to switch displayed units between Fahrenheit (°F) and Celsius (°C).
• DISPLAY BRIGHTNESS
To adjust the brightness of the display, set the controller to OFF Mode, then
press the up or down button to increase or decrease the brightness level. The
brightness range is 1/2/3/A3.
• TEMPERATURE CALIBRATION
To adjust the temperature that the probe sensor is measuring, press the MODE
and UP button simultaneously. This can be done while the controller is any
mode. The calibration cycle ranges from -8°F to 8°F (or -4°C to 4°C). You may
use this setting to match the controller’s temperature reading with your
thermostat’s reading.
• HUMIDITY CALIBRATION
To adjust the probe sensor’s humidity reading, press the MODE and DOWN button
simultaneously. This can be done in any mode. The calibration cycle ranges
from -8% to 8%.
• CONTROLLER LOCK
To lock the controller and prevent accidental setting changes, hold the LEAF
button for three or more seconds. While the display is locked, you will not be
able to switch modes or adjust settings. You will only be able to put the
controller in ECO display. Holding the LEAF button for three or more seconds
will unlock the controller.
• ECO-MODE
The controller can be put into ECO display in which the screen will be turned
off but all programs, settings, and alarms will be running in the background.
This can be done by pressing the LEAF button. You may also do this while the
controller is locked. To exit ECO display, simply press any buttons.
• ALERT ICONS
On the top left of the display is the alert icon section. Icons may flash when
the controller wishes to alert you that a particular function or alarm is
being triggered.
DISPLAY LOCK ALERT
This icon is visible when the controller has been locked. The icon will flash to alert you that the controller is locked if you try to change the mode or settings.
HUMIDITY ALARM ALERT
This icon will flash when the high or low humidity alarm that you have set has been triggered.
TEMPERATURE ALARM ALERT
This icon will flash when the high or low temperature alarm that you have set has been triggered.
CHECK FAN ALERT
This icon will flash when the fan’s sensor detects interference to its operation. Please check the fan for possible issues. If the fan is rotating, it may just be static pressure resistance and operating as intended. If the fan is not rotating, please see the warranty page for replacement information. (This feature is only available on certain model.)
DOWNLOAD THE APP
-
Search “Power Life” in Apple Store or Google Play Store to download the APP. Alternatively, you can scan the QR code below to download the APP and view the APP instructions.
-
Register and log in to the APP and add a device by clicking Add Device in the interface below or the + button in the upper right corner of the interface.
Note
- Before connecting make sure your phone is connected to WIFI. WIFI connection only supports 2.4GHz Wi-Fi band.
- If you change the mobile phone or network, you need to press and hold the UP button for more than 5 seconds in OFF mode (“ ” appears and flashes) to clear the WIFI before reconnecting.
CONTROLLER SHORTCUTS
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>