Grelife JDJSQ0002AGL-BK Warm and Cool Mist Humidifier User Manual
- June 15, 2024
- Grelife
Table of Contents
- Grelife JDJSQ0002AGL-BK Warm and Cool Mist Humidifier
- SAFETY INSTRUCTIONS
- AFTER USING THE HUMIDIFIER
- Maintenance instructions.
- FEATURES
- SPECIFICATIONS
- PRODUCT DIAGRAM
- OPERATIONS AND FUNCTIONS
- CLEANING AND MAINTENANCE
- TROUBLESHOOTING GUIDE
- WARRANTY & CUSTOMER SUPPORT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Grelife JDJSQ0002AGL-BK Warm and Cool Mist Humidifier
STATEMENT
Thank you for purchasing the Grelife LE-H003 Warm and Cool Mist Humidifier.
Please read this user manual carefully and keep it for future reference. If
you need any assistance, please contact our support team with your product
model number and order number.
SAFETY INSTRUCTIONS
The humidifier was made with safe and environmental protection materials, it has been certified and complied with the requirement of sale regions’ related regulations or laws. IMPORTANT: Please read and save this SAFETY INSTRUCTIONS before using the device. Basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons or damage to the product.
BEFORE USING THE HUMIDIFIER
- A collision with a hard object may cause the product to rupture, please handle with care and do not hit the hard object.
- DO NOT place this humidifier in wet environments.
Please always keep the humidifier out of reach of patients & children & pets.
- Please always place the unit on a smooth, flat, lint-free, non-metallic, waterproof and level surface and keep it away from direct sunlight.
- Always place the unit 2 feet (60 cm) above the floor, 12 inches (30 cm) away from the wall, other appliances or wooden furniture.
- DO NOT place the unit on carpet, towel or wood surface, which will block the vent and may damage the unit.
- DO NOT place the humidifier near naked flames and heat sources, such as stove tops, ovens, radiators or computers.
- Please extend the cord and check any signs of damage. Do not use the humidifier if the cord has been damaged.
WHEN USING THE HUMIDIFIER
- DO NOT plug the unit with wet hands.
- DO NOT direct the mist nozzle against the wall.
- DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid damaging the product or causing injury.
- DO NOT clean the unit while it is connected to a power source or while it is on .
- DO NOT move or tilt the humidifier while it is in operation.
- The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.
AFTER USING THE HUMIDIFIER
- Always disconnect from a power source by pulling the plug when not in use.
- Humidifier requires regular cleaning. Please refer to, and follow the Cleaning and
Maintenance instructions.
DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier.
PACKAGE CONTENTS
- l x Humidifier (Model: LE-H003)
- l x User Manual
FEATURES
-
Top-fill Water Tank Design
Make filling and cleaning easier -
Five-speed Mist adjustment
Set your desired humidity level -
360° Rotary Nozzle
Turn the mist output toward any direction -
ULTRASONIC COOL & WARM MIST
Stay cozy and comfortable whilst breathing properly all year round -
LARGE LED DIGITAL SCREEN
Easily get functions like humidity, temperature and settings easily -
Auto Shut Off Protection
Stop working automatically when out of water -
5L Transparent Water Tank
Conveniently observe the surplus water at any time -
Timer Function
12 Hours timer settings for the appropriate working time
SPECIFICATIONS
Model | LE-H003 |
---|---|
Operating Voltage | AC 120V/60Hz |
Rated Power | Max: 95W |
Water Tank Capacity | SL |
Working Time on A Full Tank | 13-35h |
Recommended Room Size | 25m2 I 269ft2 |
Noise | :S;36dB |
Dimensions | 238 x 182 x 343mm / 9.4 x 7.2 x 13.Sin |
Net Weight | 1840g / 169oz |
**** Mist Output | Min: 100ml/h Max: 320ml/h |
PRODUCT DIAGRAM
- Top Cover
- Mist Outlet
- Water Tank
- Operation Panel
- Sink
- Power Cord
OPERATION AREA
- On/off Button
- Constant Humidity Button
- Timer Button
- Mist Level Button
- Warm Mist Mode Button
- Light/sleep Mode Button
- Humidity Level Icon
- Mist Level Icon
- Constant Humidity Icon
- Clean Reminder Icon
- Timer Icon
- Humidity Unit Icon
- Sleep Mode Icon
- Water Shortage Icon
- Warm Mist Mode Icon
OPERATIONS AND FUNCTIONS
Add water
- Remove the tank cap.
- Fill the tank with clean and cool water only.
- Attach the tank cap and place the tank back onto the base.
- Please make sure it fits together securely so that water can go from the tank to the reservoir.
Power On / Off and Mist Adjustment
Plug the power cord into a wall socket. Now the humidifier is ready for use.
- Plug in the power, and then touch the On/Off button, the device starts to work with Standard mist mode, the digital display will turn on.
- In any working mode, touch this button, will turn off the humidifier and digital panel.
The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.
Standard Mist Mode / Mist Level Adjust
Touch the button, to enter the standard mist mode, you can adjust the mist
amount by touching this button several times. Total 5 mist amount levels.
Mode | Levels | Mist Amount |
---|---|---|
Cold Mist | Level 1 | 70~120ML/H |
Level 2 | 120~l 70ML/ H | |
Level 3 | 170~200M L/ H | |
Level 4 | 200~2S0M L/ H | |
Level s | >2S0ML/ H | |
Warm Mist | Level 1 | 120~ l 70M L / H |
Level 2 | 170~220M L / H | |
Level 3 | 220~2S0M L/ H | |
Level 4 | 270~320ML/H | |
Level s | >320ML/ H |
Constant Humidity Mode
- The most comfortable humidity is about 40%-60%, the constant humidity mode could adjust humidity and provide the most comfortable environment.
- Touch the button to enter the constant humidity mode and setting, the humidity icon is on and the number of humidity is blinking, the target humidity number can be increased/ decreased by touching the humidity button again, the range of humidity mode is 30%-80%, touch the button or no more operations for within 5 seconds, fixed this setting.
- In constant humidity mode, can’t adjust the mist level by the button, and the mist mode works in maximum level by default.
- When the set humidity is reached, the humidifier stops atomizing.
Warm Mist Mode
- Touch the button to enter the warm mist mode, the warm mist icon is on.
- In this mode, the humidifier will quick humidify, and this temperature of the mist outlet is about 45°C.
Timer Mode
- Touch the button to set the timing shutdown, can increase/decrease the timing shutdown value by touching this button again. The setting range: 0-12 hours. If there is no more operations within 5 seconds, fixed this setting.
- Touch the button 1.5s, will log out the timer mode.
Light Control
Touch the button to turn on or turn off the light.
Sleep Mode
Touch the button 1.5 seconds to enter the sleep mode, only the sleep indicator
lights up in this mode, operation sound and the light are off. A single touch
of any icon will light up the corresponding status indicator, you can continue
to make relevant settings, and the status indicator turns off after 5seconds.
CLEANING AND MAINTENANCE
Caution
- DO NOT submerge the base in water.
- Make sure water does not enter the base through the air outlet, air inlet, or the control knob.
- DO NOT wash any part of this humidifier in the dishwasher which will damage the humidifier and void the warranty.
Daily Maintenance
After each use of the humidifier, pour out the remaining water and dry it
before storage.
Weekly Maintenance
- To properly clean your humidifier, we recommend you to remove scale and disinfect the humidifier separately.
- DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. of bleach per gallon of water to avoid damaging your humidifier.
- Please make sure the sealing ring on the tank cap is installed properly after cleaning to avoid water leakage.
- Clean and maintenance the humidifier once it is used continuously for 3 days.
- When the humidifier is not used for a long time, it is recommended to dry the device before storage.
- Prepare a cotton swab/brush/mild detergent before cleaning.
- Please turn off the humidifier and unplug it before cleaning.
- Once the humidifier is used continuously for 3days (humidifying mode), the cleaning reminder icon will light automatically to remind the customer cleaning the humidifier. Long touch button for 2 seconds, can cancel this remindier.
Cleaning The Water Tank
- Remove the water tank and pour out the remaining water in the device.
- Take out the filter and clean it separately with a brush or cotton swab.
- Rinse the inside and bottom of the tank with water.
- When there are water stains that are difficult to remove, can add an appropriate amount of mild detergent to soak for 30 minutes and then clean them.
Note: Do not use organic solvents, strong acids, strong alkalies and other substances for cleaning.
Cleaning The Sealing Ring
- If there are the objects in the sealing ring of the water outlet of the water tank, it will cause the sealing to be loose and cause water leakage.
- Please lift up the spring, and use a cotton swab to carefully remove the objects around the sealing ring at the water outlet.
Cleaning The Sink
Please clean the sink with a damp cloth or brush.
Notice
-
It is not recommended to directly rinse the sink with water, to avoid water splashing into the base from the air outlet. If water drips into the base, it will directly affect the normal operation
of the product. -
When cleaning the sink, if you accidentally drop water into the air outlet, do not plug in the device, and place the device on the front. Then let the water drain through the base drain hole, and drain in the ventilated place for 3 days, until the water is fully evaporated before use.
TROUBLESHOOTING GUIDE
- If the information listed in the troubleshooting guide can’t solve your problem, please email us for help.
- Failure to keep this unit clean from mineral deposits may affect operation of this unit.
- Customer failure to follow these instructions may void the warranty.
- Spring
- Sealing Ring
- Water Floater
Problem Possible Cause Solution
LED indicator is off| Unit not plugged in| Ensure unit is properly plugged in
No power from power outlet| Try another power outlet
Did not turn on the unit| Check the Control Knob is turned to the working po
sition .
Water shortage icon lights up| No water in the water reservoir| Ensure the 1
Spring is secured properly to the tank bottom allowing water to pass through
to the base
3 water floater stuck| Adjust the 3 water floater to a horizontal position
and make sure it can rise up with water
The LED Indicator is green but no mist or little mist is produced| Not enough
water inside the tank| Refill and reinstall the water tank
---|---|---
Mist level is set too low| Adjust to maximum mist
Mineral buildup on the atomize| Feel if any air comes out from the nozzle. If
yes, then clean water scale on the atomizer as instructed
The base might be overfilled| Remove the tank, empty the base and place the
filled tank on the empty base
Tank leakage| Tank may be damaged| Check for possible crocks in the tank. If
there is a crock, please contact our customer service to solve it.
Dust and impurities in the water tonk| lean the water tonk. Make sure there is
no dust over 1 the spring and 2 sealing ring
1 Spring stuck| Ensure the 2 spring is properly secured to the tonk bottom
allowing water to poss through to the base.
2 Sealing ring was not installed on tonk cop| Install the 2 sealing ring on
the tonk cop, please contact us if it is missing
Mist height is low, damping surrounding desk or floo r. Condensation forms
around humidifier or on windows and walls| Mist level is set too high for the
room size|
- Check if the room is too humid and adjust to lower mist. 40%-60% works best
- Open door and windows, or change to a larger room
Air inlet is blocked| Humidifier should be placed on a hard flat su rfac e ,
make sure no objects around the air inlet .
Low indoor temperature leads to liquefaction| Raise the room temperature to
25°C I 77°F
Poor humidification| Mist level is set too low for the room size| 1. Adjust
to maximum mist
2. Close door or windows to reduce air ventilation, or change to a smaller room
---|---|---
Air inlet is blocked| Humidifier should be placed on a hard flat surface, 2
feet above the floor, 12 inches away from the wall
Low indoor temperature leads to liquefaction| Raise the room temperature to
2s0 c I 77°F
White dust appears or the block coating on the base flakes off| Top water may
contain too much minerals| Replace with filtered or distilled water
Strange Odor| Cleon the unit|
- Cleon the humidifier as instructed
- Leave the empty and opened water ton in a cool place for 12 hours without the tank cop attached
Strange water noise| Water is going down to the water reservoir| This is
normal while it is working
Humidifier is getting too hot| Unit works for too long| Power off and place in
a well-ventilated place for 10 minutes
WARRANTY & CUSTOMER SUPPORT
For questions, support, or warranty claims, contact us at the address below that corresponds with your region. Please include your order number and product model number.
-
E-mail: support@grelife.net
-
Please note, Grelife can only provide after sales service for products purchased directly from Grelife. If you have purchased from a different seller, please contact them directly for service or warranty issues.
Grelife
WARM AND COOL MIST HUMIDIFIER E-mail:
support@grelife.net
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>