BULIST UD01 Smart Lock with Voice Prompts Instruction Manual
- June 14, 2024
- BULIST
Table of Contents
UD01 Smart Lock with Voice Prompts
Instruction Manual
Appearance display
Function definition
Normal user code
- Support 50 groups of normal user code (4-8 digital codes)
- The default normal user code is “123456”
One-time user code
- Support 10 groups of one-time user code(48 digital codes)
- One-time user code can only be used once, and will be automatically delete after use.
Anti-peek
Anti-peek when input user code Low Battery Alarm
When the battery voltage is lower than 4.8V, low battery alarm will be
prompted by voice when unlocking. Please replace the battery as soon as
possible
Error Input Limit
More than 5 consecutive input error user code, and the keypad will be
locked or 90 seconds
Lock Failure Alarm
Send alarm when unlock and lock failed place the new battery
Voice guidance
- Real person voice assistance
- Support 5 level volume adjustment
- Default 3 level volume
Auto Lock
- Delay 10 seconds to automatically lock after unlocking
- Function can be enable or disable
- Delay time range 10 to 99 seconds
Emergence M-Key
- The M-key can be used to unlock when the lock fails or no power
- Recommend putting the M-key in the office or car
How to use
Outdoor unlock Enter user code and press unlock key to confirm Turn the
M-key to unlock
Indoor unlock Rotate hand knob to unlock position Press unlock/lock
button
Outdoor lock Automatic locking after delay 10 seconds Press lock key
Indoor lock Automatic locking after delay 10 seconds Press unlock/lock
button
How to replace battery
- When the lock send the low battery alarm, please replace the battery.
- AA alkaline battery 4pcs
- Do not mix new and old batteries
- The new battery can be used for about one year (10 times lock or unlock per day)
Troubleshooting
Question | Answer |
---|---|
Can not add new user code | •If 50 groups of normal user code have been added, |
you can delete the unused user code and add new user code again
•The new user code is duplicate
•Only support 4 to 8 digit user code
Keypad light flashing| The battery voltage is low, please replace the battery
Forget password| Restore the factory settings, and then add the user
Can’t hear the voice guidance clearly| Increase volume through function
setting
The latch bolt cannot extend| •Check whether auto locking function is enable
•Please check the lock is installed correctly
The system is locked and the user code can not be entered| Input error reached
5 times, system has been locked, enter user code in 90 seconds
How to setting?
Add user code
‘If the user code is not configured, this step will be skipped Delete user code Automatic locking
function setting
*If the user codes not configured, this step will be skipped Adjust
volume Restore factory setting
QUALIFIED CERTFICATE
MODEL: ……………..
CHECKER:………………….
DATE:………………………………
If you have any question during product use, please contact our after-sales service team, thanks.
E-mail: bulist.services@outlook.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>