MEAN WELL GST160A Series 160W Reliab Green Industrial Adaptor User Manual
- June 14, 2024
- MEAN WELL
Table of Contents
- MEAN WELL GST160A Series 160W Reliab Green Industrial Adaptor
- Product Information
- Product Usage Instructions
- Features
- Applications
- Description
- Model Encoding
- SPECIFICATION
- Derating Curve
- Mechanical Specification
- Installation Manual
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL GST160A Series 160W Reliab Green Industrial Adaptor
Product Information
Specifications
-
Product Name: 160W AC-DC Reliable Green Industrial Adaptor
-
Model: GST160A series
-
Input Voltage: Universal AC input / Full range
-
Output Power: 160W
-
Input Efficiency: 90%
-
AC Current: 1.85A / 115VAC, 1A / 230VAC
-
Overload Protection: 105 ~ 150% rated output power
-
Working Temperature: -30°C to +70°C
-
Working Humidity: 20% ~ 90% RH non-condensing
-
Storage Temperature, Humidity: -40°C to +85°C, 10% ~ 95% RH non-condensing
-
Safety Standards: UL62368-1, BS EN/EN62368-1, RoHS, J62368-1,
K60950-1, AS/NZS60950-1, GB4943.1, IS13252, MS IEC60950-1, IEC62368-1, TPTC004 (optional) -
EMC Emission: BS EN/EN55032 (CISPR32), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B), CNS13438, GB17625.1 Class B, EAC TP TC 020, MSIP KN32
-
EMC Immunity: BS EN/EN61000-4-2, BS EN/EN61000-4-3, BS
EN/EN61000-4-4, BS EN/EN61000-4-5, BS EN/EN61000-4-6, BS
EN/EN61000-4-8, BS EN/EN61000-4-11 -
MTBF: 2205.4K hrs min. Telcordia SR-332 (Bellcore), 236.4K hrs min. MIL-HDBK-217F (25)
-
Dimensions: 1757235mm (LWH)
-
Weight: 0.66Kg
Product Usage Instructions
Step 1: Connection
- Connect the 3-pole AC inlet IEC320-C14 to the power source.
- Connect the other end of the adapter to the device you want to power.
Step 2: Power On
- Ensure that the power source is turned on.
- Press the power button on the device to power it on.
Step 3: Monitoring
- Monitor the device to ensure it is receiving power from the adapter.
- Check the LED indicators on the device to verify the power status.
Step 4: Power Off
- Press the power button on the device to turn it off.
- Disconnect the adapter from the power source and the device.
Frequently Asked Questions (FAQ)
Q: What is the input voltage range for this adapter?
- A: The adapter has a universal AC input range, which means it can accept any voltage within the specified range (e.g., 100-240VAC).
Q: What is the output power of this adapter?
- A: The output power of this adapter is 160W.
Q: What is the working temperature range for this adapter?
- A: The working temperature range for this adapter is -30°C to +70°C.
Q: What are the safety standards that this adapter complies with?
- A: This adapter complies with UL62368-1, BS EN/EN62368-1, RoHS, J62368-1, K60950-1, AS/NZS60950-1, GB4943.1, IS13252, MS IEC60950-1, IEC62368-1, and TPTC004 (optional) safety standards.
Features
Global certificates
- Universal AC input / Full range
- 3 pole AC inlet IEC320-C14, Class I power unit
- Built-in active PFC function
- No load power consumption<0. 15W
- Energy efficiency Level VI
- Comply with EISA 2007/DoE, NRCan, AU/NZ MEPS, EU ErP, and CoC Version 5
- Protections: Short circuit / Overload / Over voltage / Over temperature
- -30~+70°C wide range working temperature
- Fully enclosed plastic case
- LED indicator for power on
- Various DC plug quick adapter accessories are available
- (Plug kit sold separately, please refer to: https://www.meanwell.com/upload/pdf/DC_plug.pdf)
- 3 years warranty
Applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
- GST160A is a highly reliable, 160W desktop-style single-output green adaptor series. This product is a class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 85VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices.
- With an efficiency of up to 94% and extremely low no-load power consumption below 0.15W, GST160A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea K-MEPS, EU ErP and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame-retardant plastic case.GST160A is certified for international safety regulations.
Model Encoding
SPECIFICATION
ORDER NO.| GST160A12- R7B| GST160A15- R7B|
GST160A20- R7B| GST160A24- R7B| GST160A36- R7B|
GST160A48- R7B
---|---|---|---|---|---|---
OUTPUT| SAFETY MODEL NO.| GST160A12| GST160A15| GST160A20|
GST160A24| GST160A36| GST160A48
DC VOLTAGE **Note.2| 12V| 15V| 20V| 24V| 36V| 48V
RATED CURRENT| 11.5A| 9.6A| 8A| 6.67A| 4.44A| 3.34A
CURRENT RANGE| 0 ~ 11.5A| 0 ~ 9.6A| 0 ~ 8A| 0 ~ 6.67A| 0 ~ 4.44A| 0
~ 3.34A
RATED POWER (max.)| 138W| 144W| 160W| 160W| 160W| 160W
RIPPLE & NOISE (max.) Note.3| 80mVp-p| 100mVp-p|
120mVp-p| 150mVp-p| 150mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±3.0%|
±3.0%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±3.0%| ±3.0%
SETUP, RISE TIME ****Note.6| 2000ms, 50ms / 230VAC
2500ms, 50ms / 115VAC at full load
HOLD UP TIME (Typ.)| 20ms / 230VAC 20ms / 115VAC at
full load
INPUT| VOLTAGE RANGE ****Note.7| 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| 12V/15V:PF>0.93 / 230VAC
20V,24V,48V:PF>0.94 / 230VAC PF>0.98 / 115VAC at full load
EFFICIENCY (Typ.)| 90%| 91%| 93%| 93%| 92%| 94%
AC CURRENT| 1.85A / 115VAC 1A / 230VAC
INRUSH CURRENT (max.)| Cold start 95A / 115VAC 120A /
230VAC
LEAKAGE CURRENT(max.)| 0.75mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
OVERVOLTAGE| 105 ~ 135% rated output voltage
Protection type: Hiccup mode @ 10%load
OVER TEMPERATURE| Protection type: Shut down o/p voltage, re-power
on to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating
Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃ , 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0~50℃ )
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC**
(Note. 9)
| SAFETY STANDARDS Note. 8| UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1
BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved
WITHSTAND VOLTAGE| I/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG:SHORT
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32
| Class B
Radiated emission| BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32
| Class B
Harmonic current| BS EN/EN61000-3-2,GB9254| Class A
Voltage flicker| BS EN/EN61000-3-3| ——-
EMC IMMUNITY| BS EN/EN55035
Parameter| Standard| Test Level /Note
END| BS EN/EN61000-4-2| Level 4, 15KV air; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 2, 3V/m
EFT bursts| BS EN/EN61000-4-4| Level 3, 2KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line , 2KV/Line-FG
Conducted susceptibility| BS EN/EN61000-4-6| Level 2, 3V
Magnetic field immunity| BS EN/EN61000-4-8| Level 2, 3A/m
Voltage dips, interruption| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip
25 periods,
>95% interruptions 250 periods
OTHERS
| MTBF| 2205.4K hrs min. Telcordia SR-332 (Bellcore); 236.4K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 1757235mm (LWH)
PACKING| 0.66Kg; 20pcs/ 14.2Kg/ 0.95CUFT
CONNECTOR
| PLUG| See page 4~5; Other type available by customer requested
CABLE| See page 4~5; Other type available by customer requested
NOTE|
- All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
- DC voltage: The output voltage set at the point measured by the plug terminal & 50% load.
- Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1μf & 47μf capacitor.
- Tolerance: includes set up tolerance, line regulation, and load regulation.
- Line regulation is measured from the low line to the high line at the rated load.
- The length of set-up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time.
- Derating may be needed under low input voltage. Please check the derating curve for more details.
- The demand for Malaysia safety is processed with order no. GST160A-SIRIM by request. Please contact MEAN WELL for details.
- The power supply is considered an independent unit, but the final equipment still needs to confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Derating Curve
Static Characteristics
Mechanical Specification
DC output plug
- Standard plug: R7B
DC plug changeable through:
- Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
- Quick adapter accessory (sold separately without MOQ)
- Please refer to below table and online selection guide below: https://www.meanwell.com/upload/pdf/DC_plug.pdf
Example quick adapter accessory;
Optional DC plug: (Available in customized cable or quick adapter)
Installation Manual
- Please refer to: http://www.meanwell.com/manual.html
- Downloaded fromArrow.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>