Hcalory SS2 Diesel Air Car Parking Heater User Manual

June 14, 2024
Hcalory

Hcalory SS2 Diesel Air Car Parking Heater

Hcalory SS2 Diesel Air Car Parking Heater

Important Information

NOTE: Please read this manual carefully before use to understand the function and operation requirements of the product.
Feathers

Function Overview

This product can reduce the damage caused by sudden temperature drops to cars, increase the temperature inside the car, preheat the engine coolant and avoid wear of the engine wear at low temperatures. It is conducive to thawing inside the car, starting the car, and defogging car glass. This product is another heating system that is independent of the vehicle’s original heating system. Regardless of whether the vehicle’s engine is running or not, the driver’s cab can be heated, and it can be even used in camping tents and household rooms.

Internal structure of the main machine

Internal structure of the main machine

Product Information

  1. Hot air outlet
  2. Machine upper cover
  3. Exhaust pipe
  4. Metal buckle
  5. Power input interface
  6. Air inlet
  7. Switch remote control placement box
  8.  Air filter
    Product Information

Product structure diagram

Product structure diagram

Remote Control Operation Instructions

[Note: The remote control uses two CR2025 button batteries that are needed to be configured by users themselves. The product does not include batteries.] Remote Control Operation Instructions

Overall display and key definition

Work mode

  1. In gear mode, the gear can be adjusted and set within the range of 1-10 gears;
  2. In temperature control mode, the set temperature can be adjusted within the range of 8-36°C. The gear position of the control switch changes with the temperature inside the cab. When the temperature rises or decreases, the control switch will automatically adjust the operating gear to reach the set temperature quickly, making the heater operate more intelligent and economical;
  3. When a fault occurs during operation, the control switch display window will flash to display the fault code, making it easier to find the fault more accurately and intuitively.
Operating instructions

On/Off: Press the (On/Off key) to power on the machine in the shutdown state; Press the button (on/off key) to power off the machine in the startup state;

Quick oil pumping: in the state when the heater motherboard is connected with power for the first time and shutdown state, hold down ( key) for three seconds to enter the oil pumping mode. The screen displays a 300s countdown to start pumping oil. After the countdown is completed, it will automatically exit and shut down. Press the (On/Off key) halfway to exit the oil pump mode and shut down the machine;

Quick language switching: Press the (setting key) and (down key) simultaneously for 3 seconds in the startup state to switch languages ( for voice off, for English, for German, and for Russian).

Fill the fuel tank : hold down the ( key) for 3 seconds after starting the machine, and the screen will display to set the full fuel tank. The fuel tank icon on the operation interface will be in full state;

Mode switching : in the startup state, press (setting key) to switch between the gear mode and temperature control mode.

Gear adjustment: Press (up key) to increase run gear/temperature by 1, up to 10 gear/36°C, press (down key) to decrease run gear/temperature by 1, down to 1 gear/8°C;

Basic settings: After powering on, hold down (setting key) for 3 seconds to enter the basic setting interface. The setting items are displayed directly on the top of the screen. Press (up key) to adjust item by increasing 1. Press (down key) to adjust item by decreasing 1. The interface displays the specific data for the setting item:

FO: Current time;
F1: Self start time;
F2: Running time [after self start] F3: Self start switch setting;
F4: Language switching [E English, G German, r Russian, – Voice off];
FS: Temperature compensation [range -9°C~+9°C] ;
F6: Fuel volume in the fuel tank [5-50L [switch unit: SL)] [Display – represents not monitoring the fuel tank condition] ;
F7: Oil pump type [16/22/28/32UL [default: 22UL)] ;
FS: Automatic start/stop heating switch; (In temperature control mode, when the cab temperature reaches the set temperature, it will automatically shut down after a delay of 30 seconds; when the cab temperature is 2°C lower than the set temperature, it will automatically start up after a delay of 30 seconds).
F9: Bluetooth matching switch
FA: Remote control matching switch;
Fb: switch between Celsius °C/Fahrenheit °F;

Press (setting key) to modify, press (up key)/ (down key) to modify the current data, and press again (settings key) to confirm the current item. After all modifications within the basic settings are completed, hold down (setting key) for 3 seconds to save the modified data and exit from the running interface;

Engineering mode: in the startup state, hold down (up key) and (down key) for 3 seconds to enter the engineering mode. The upper left corner displays the current item. Press (up key) to increase the item by 1 and press [ (down key) to decrease the item by 1. The interface displays the specific data of engineering mode: After viewing, press (on/off key) to exit to the homepage.

En00: Heater motherboard version number [scrolling display]

En01: Fault code [see table below for details]
En02: Shell temperature
En03: Power supply voltage
En04: Heater running gear
En05: Cab temperature
En06: Altitude
En07: Manual pump oil
En08: Remote control matching
En09: Bluetooth matching

Remote control quick matching:
In the startup state, press (up key) for 3 seconds and the screen will display “rte”. Press any key on the remote control to match, and once the matching is completed, it will automatically exit from the running interface;

Clear the last remote control matching data:
During the power on self test, hold down (on/off key) and the interface displays “CLr” to start clearing. Release the key until the screen displays “SUC”. This means that the clearing of remote control matching data is successful.

Bluetooth matching:
Please download the APP as follows, and then follow the steps to connect and control the heater through Bluetooth on your phone.

Android APP :
Search ”Air Heater BLE” in Google Mall or directly scan the following QR code to download.| IOSAPP:
Search “air Heater Ble” in the APP store or scan the following QR code to download directly.
---|---
QR-Code| QR-
Code

  1. Query the Bluetooth name of the controller: after power on, press  (Setting key) (On/Off key) for 3S at the same time and the screen displays “bLE”.
    The upper side of the screen displays 6 characters with the name (0-F). If there is no Bluetooth module or the name acquisition is failed, the upper side of the screen displays “NULL”. Press any key again to exit.
    Remote Control Operation Instructions

  2. Connect the mobile APP to the controller through Bluetooth: Click the Bluetooth symbol in the upper right corner of the APP program and find the corresponding controller Bluetooth number: BYD+MAC address+4 letter and number (refer to the above figure), and then click the Bluetooth number to connect;
    Bluetooth matching

  3. Hold down l to turn off or start the heater.
    Bluetooth matching

  4. Click the button to go to the settings page. You can set the language (English/Chinese) and password, and then click the “save” button to save the settings.
    After changing the password on the APP, please pay attention to updating the password of the controller switch synchronously. Adjust the controller switch to enter engineering mode En09, and the interface displays “bLE”. Hold down controller (setting key) for 3 seconds, the flashing of original password is changed to display of setting mode on the upper right corner and the interface display changes to “SUC”. After the update is successful, it will automatically return to the running interface;
    Please note that the mobile phone APP password and controller switch password must be consistent in order to connect.

  5. Click “mode” button to switch between gear mode and temperature control mode, and then click “up+”/”down -” to increase or decrease (gear 1-10)/temperature (8°C~36°C);
    Bluetooth matching

  6. Fault error display: When the heater malfunctions, the display area flashes a fault code. Please refer to the table below for the fault type and troubleshooting operation.

Fa u lt code| Fault Type| Tr oubleshoot in g
---|---|---
E-01| Abnormal voltage| Check if the type of heater supply voltage matches the actual vehicle voltage;
For the version of 24V, check if the power supply voltage is higher than 32VA or lower than 18V;for the version of 12V, check if the power supply voltage is higher than 18V or lower than 9V. check if the connecting of main wire harness comes loose.
E-03| Abnormal ignition plug| Check if the ignition plug is connected firmly; if the ignition plug fails, replace the ignition plug; if the motherboard fails, replace it;
E 04| Abnormal oil pump| Check if the oil pump plug is loose or not connected firmly;
Check if there is an open circuit in the main harness; if the oil pump fails, replace it;
E 05| Overheat protection| The furnace temperature sensor model is incorrect or faulty, replace the sensor; if the motherboard fails, replace it;
E-06| Abnormal fan| Check if the fan impeller is stuck; Check if the fan plug is loose or not connected firmly; if the fan fails, replace it.
Check if the induction magnet of the wind wheel is missing or has incorrect polarity; Check whether the motherboard wind speed sensor is normal; if the motherboard fails, replace it;
E-08| Lack of fuel and stalling| Check if the fuel tank is short of oil;
E 09| Overheat protection sensor| Check if the temperature sensor connector is loose or not connected firmly;
if the sensor fails, please replace the motherboard. If the motherboard fails, replace it.
E-10| Second startup failure| Check if the oil pump works; Check if the interfaces of the oil circuit are waxed or blocked;

FCC STATEMENT:

FCC ID:Symbols

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Customer Support

Contact us

You can email us for any question about Hcalory products to the address [email protected] or contact us at corresponding sales link. Thank you for your feedback and support.

EU importer: VISHTEC ltd
Address: 3 rd floor office 5, Plovdiv 2 Liuben Karavelov bul, 4002 Bulgaria
Email: [email protected]
UK lmporter:VISHTEC UK Co.,Ltd
Address: 275 ISLINGTON SUITE 1405 NEW NORTH ROAD LONDON ENGLAND N1 7AA
Email: [email protected]

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hcalory User Manuals

Related Manuals