1. BEFORE YOU BEGIN
1.1 PRODUCT DESCRIPTION
Our powerful portable air conditioners are great cooling solutions for single
rooms, creating a comfortable atmosphere in your space. It also has
ventilation and dehumidifying function for circulating air and removal of
moisture. They’re self-contained systems that do not require any permanent
installation allowing you to move to the space in which it is most needed.
They’re commonly used in kitchen, temporary-resided, computer rooms, garages,
and many other places where installation of Air-conditioner Outdoor Unit is
limited.
The environmentally friendly R290 is used as the refrigerant. R290 has no
damaging influence on the ozone layer (ODP), a negligible greenhouse effect
(GWP) and is available worldwide. Because of its efficient energy properties,
R290 is highly suitable as a coolant for this application. Special precautions
must be taken into consideration due to the coolant’s high flammability.
1.2 SYMBOLS FROM THE UNIT AND USER MANUAL
This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating part, it will
create harmful gas and there is risk of fire.
Read the USER MANUAL carefully before operation.
Further information is available in the USER MANUAL, SERVICE MANUAL, and the
like.
Service personnel are required to carefully read the USER MANUAL and SERVICE
MANUAL before operation.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating
ignition sources (for example: open flames, an operating gas appliance or an
operating electric heater.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Appliance shall be installed, operated and stored in a room with a floor area
larger than 10 m2
THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- The unit is designed only for use with R-290(propane) gas as the designated refrigerant.
- The refrigerant loop is sealed. Only a qualified technician should attempt to service!
- Do not discharge the refrigerant into the atmosphere.
- R-290 (propane) is flammable and heavier than air.
- The maximum refrigerant charge amount: 200g
- It collects first in low areas but can be circulated by the fans.
- If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.
- The propane gas used in the unit has no odor.
- The lack of smell does not indicate a lack of escaped gas.
- If a leak is detected, immediately evacuate all persons from the store, ventilate the room and contact the local fire department to advise them that a propane leak has occurred.
- Do not let any persons back into the room until the qualified service technician has arrived and that technician advises that it is safe to return to the room.
- No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.
- Component parts are designed for propane and non-incentive and
non-sparking. Component parts shall only be replaced with identical repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.
2. FOR YOUR SAFETY
Please read this manual carefully and fully understand before operating your appliance.
2.1 OPERATIONAL PRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to persons or
property:
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The appliance shall be disconnected from its power source during service.
- Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
- Always use a power outlet that is grounded.
- Unplug the power cord when cleaning or when not in use.
- Do not operate with wet hands. Prevent water from spilling onto the unit.
- Do not immerse or expose the unit to rain, moisture or any other liquid.
- Do not leave the unit running unattended. Do not tilt or turn over the unit.
- Do not unplug while the unit is operating.
- Do not unplug by pulling on the power cord.
- Do not use an extension cord or an adapter plug.
- Do not put objects on the unit.
- Do not climb or sit on the unit.
- Do not insert fingers or other objects into the air outlet.
- Do not touch the air inlet or the aluminum fins of the unit.
- Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
- Do not clean the appliance with any chemicals.
- Ensure the unit is far away from fire, inflammable, or explosive objects.
- The unit shall be installed in accordance with national wiring regulations.
- The installation of pipe-work shall be kept to a room with a floor area larger than 10 m2
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than lOm2
- Compliance with national gas regulations shall be observed.
- WARNING: Keep any required ventilation openings clear of obstruction.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation. Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
- Fuse: AC250V 2A; T type Or F type AC250V 3.15A; T type Or F type
Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
If you don’t understand something or need help, please contact the dealer services.
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing an appliance with R290.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimized. For
repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
2.2.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the
risk of a flammable gas or vapor being present while the work is being
performed.
2.2.3 General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out. Work in confined spaces shall be
avoided. The area around the work space shall be sectioned off. Ensure that
the conditions within the area have been made safe by control of flammable
material.
2.2.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially flammable
atmospheres. Ensure that the leak detection equipment being used is suitable
for use with flammable refrigerants, i.e. no sparking, adequately sealed or
intrinsically safe.
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate fire extinguishing equipment shall be available
to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging
area.
2.2.6 No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
2.2.7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation
shall continue during the period that the work is carried out. The ventilation
should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
2.2.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed. If in doubt consult the
manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants:
- The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
- The ventilation machinery and outlets are operating adequately and are not obstructed;
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
- Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
- refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the circuit
until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate temporary
solution shall be used. This shall be reported to the owner of the equipment
so all parties are advised.
Initial safety checks shall include:
- those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
- that there no live electrical components and wiring are exposed while charging, recovering or purging the system;
- that there is continuity of earth bonding.
WARNING!
Install the unit in rooms which exceed 10 m2•
Do not install the unit in a place where inflammable gas may leak.
NOTE!
The manufacture may provide other suitable example or may provide additional
information about the refrigerant odour.
3. PRODUCT OVERVIEW
3.1 PRODUCT DIAGRAM
Note: The appearance is only for reference. Please see the real product for detailed information.
3.2 TECHNICAL CHARACTERISTICS
Refrigerant leakage contributes to climate change . Refrigerant with lower global warming potencial(GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GW equal to3. This means that if 1 Kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 3 times higher than 1 Kg of CO2, over a period of 1 OOyears. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
Energy consumption 1.11 kW/h for 60 minutes, based on the results of standard tests, the actual energy consumption will depend on the mode of production of the device and its location.
4. INSTALLATION
4.1 UNPACKING
- Unpack the carton and take the appliance and accessories out.
- Check the device after unpacking for any damage or scratches on it.
- Accessories:
• 1. Exhaust hose
• 2. Hose connector
• 3. Window kit adapter
• 4. Remote control
4.2 Choose your location
- If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
- Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
- Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.
- Never install the unit where it could be subject to:
– Heat sources such as radiators, heat registers, stoves or other products
that products that produce heat.
– Direct sunlight
– Mechanical vibration or shock
– Excessive dust
– Lack of ventilation, such as cabinet or bookcase
– Uneven surface
WARNING!
Install the unit in rooms which exceed 10 m2
Do not install the unit in a place where inflammable gas may leak.
NOTE!
The manufacture may provide other suitable example or may provide additional
information about the refrigerant odour.
4.3 ATTACH THE EXHAUST HOSE
The air conditioner requires being vented outside so that the exhaust air can
escape the room which coming from the appliance contains waste heat and
moisture.
Do not replace or extend exhaust hose which will result in decreased
efficiency, even worse shut down the unit due to low backpressure.
Step 1: Connect the hose connector to one end of the exhaust hose.
Step 2: Connect the windows kit adapter to the other end of the exhaust hose.
Step 3: Extend the adjustable window kit the length of your window.
Connect the exhaust hose to the window kit.
Step 4: Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.
Step 5: Attach the hose connector to the exhaust air outlet of unit.
Step 6: Adjusting the length of the flexible exhaust hose, and avoid bends in the hose. Then place AC near an electrical outlet.
step 7: Adjust the louver at the air outlet, and then switch on the unit.
5. OPERATION
5.1 CONTROL PANEL AND DISPLAY
5.2 REMOTE CONTROL
5.2.2 BATTERY INSTALLATION
WARNING: KEEP THE BATTERY OUT OF THE REACH OF CHILDREN.
Risk of suffocation. Don’t swallow. Harmful if swallowed. Swallowing may cause
chemical burns. Seek medical attention immediately.
Don’t let the children handle the batteries.
Do not short circuit the battery.
Do not remove the battery.
Always select the stack size and type that best suits your intended use. The
information provided with the equipment shall be retained to facilitate the
correct selection of piles for reference.
Do not connect the battery incorrectly. Always ensure that the battery is
correctly installed on the polarity ( + and -).
Do not mix battery types.
Do not mix new and old batteries.
Batteries shall not be exposed to overheating from the sun, fire or similar
sources.
Quickly remove the used battery.
Always store the battery in a cool and dry place away from sunlight. Always
check the battery before use.
The acid in the battery may be harmful, and a damaged or insufficient battery
may cause acid leakage.
After installing the battery, ensure that the battery box is correct and well
sealed, and place the battery equipment out of the reach of children. Check
the battery regularly and remove it from the equipment when it is not used for
a long time.
If the battery shows signs of leakage, deterioration or weakness at any time,
please stop using it.
Wash hands after handling batteries.
Batteries shall be properly recycled or scrapped.
1. Open the rear cover of the remote control.
2. Use two 1.5V AAA batteries (batteries not provided).
3. Install the battery.
4. Close the rear cover of the remote control and start using it!
Warning:
If you do not use the remote control for a long time, remove the battery from
the remote control.
5.3 SETTINGS
5.3.1 Start-up and Shutdown
=> Press to turn the unit on.
The unit runs in in FAN as default.
=> Press MODE button to select the desired operation mode.
=> Press again to turn off the power.
5.3.2 Operation mode
The unit has four operation modes: Cool, dry, fan, sleep.
A. Cooling your room
Select the cool mode to lower the temperature in your room.
- Press MODE button repeatedly until the LED of COOL operation lights up.
- Press Up/Down button to adjust the temperature which is displayed on the screen. The temperature can be set between l6 °C and 32·c.
- Press SPEED button repeatedly until the desired fan speed indicator lights up.
To control the direction of the air flow horizontally, please adjust the inner louver by hand.
Note: The air conditioner stops if the room temperature is lower than selected temperature.
B. Ventilating your room
-
Press MODE button repeatedly until the LED of FAN operation lights up.
In ventilation mode the room air is circulated, but not cooled. -
Press SPEED button repeatedly to select the fan speed as desired.
C. Drying your room
Press MODE button on the control panel or remote control, the LED of DRY
operation lights up. The fan speed is unable to select. User should connect
the hose to the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and cannot be
selected.
D. Sleep mode ( this function can only be used with a remote control)
The sleep mode can be activated when in cool mode.
• In cool mode :
After 1 hour the preset temperature is increased by 1 ·c, after another hour
the preset temperature will again be increased by 1 ·c.
5.3.3 TIMER SETIING ( hour-24hours)
The timer has two ways of operation:
5.3.4 Automatic Defrost
At low room temperatures, frost may buildup at the evaporator during
operation.
The unit will automatically start defrosting and the POWER LED blinking. The
defrost control sequence is as follows:
A. When the unit operates in the cooling operation, drying operation, the
ambient temperature sensor senses the evaporator coil temperature is below -1
°C, after the compressor will stop operating for 10 minutes or the coil
temperature up to TC, the unit restart to cool operating mode.
B. When the unit operates in the heating operation, drying operation, once the
coil temperature sensor senses the temperature of the evaporator is below 40°C
and the differential temperature between coil temperature and room temperature
is below 19·c after the compressor operation for 20minutes, the unit start
defrosting for 5 minutes and the power indicator blinking.
5.3.5 Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute
delay until the compressor restarting.
5.4 DRAINAGE
Self- evaporating system
The self-evaporating system uses the collected water to cool the condenser
coils for better efficient performance. It is no need to empty the drainage
tank in cooling operation except in heating operation, drying operation and
high humidity conditions. The condensate water evaporates at the condenser and
evacuated through the exhaust hose.
For continuous operation or unattended operating in drying and heating
operation, please connect the attached drain hose to the unit.
Condensate water can be automatically flow into a bucket or drain by gravity.
To avoid water spillage:
- As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
- Straighten the hose to avoid a trap existing in the hose.
6. CLEANING AND CAR
6.1. CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow
reduces the efficiency of the system and if it becomes blocked it can cause
damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy
cleaning. Do not operate the unit without an air filter, or the evaporator may
be contaminated.
- Press POWER button to switch off the unit and unplug the power cord.
- Remove the filter mesh from the unit.
- Use a vacuum cleaner to suck dust from the filter.
- Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.
Warning!!!
Do not touch the evaporator surface with bare-hand, or could cause injury of
your fingers.
6.2. CLEANING UP OF REFRIGERANT
General Measures:
- Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or below ground level.
- Eliminate every possible source of ignition.
- Use appropriate personal protection equipment (PPE).
- Evacuate unnecessary personnel, isolate, and ventilate area.
- Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
- Prevent entry to sewers and public waters.
- Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors.
- Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill.
7. TROUBLESHOOTING
8. DECOMMISSIONIN
8.1. STORAGE
Long-Term Storage – If you will not be using the unit for an extended period
of time (more than a few weeks) it is best to clean the unit and dry it out
completely. Please store the unit per the following steps:
- Unplug the unit and remove exhaust hose and window kit store with the unit.
- Drain the remaining water from the unit.
- Clean the filter and let the filter dry completely in a shaded area.
- Re-install the filter at its position.
- The unit must be kept in upright position when in storage.
- Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.
ATTENTION:
The evaporator inside the machine has to be dried out before the unit is
packed to avoid component damage and molds. Unplug the unit and place it in a
dry open area for days to dry it out. Another way to dry the unit is turn on
the machine, adjust it to low-wind ventilation mode, and maintain this state
until the drainage pipe becomes dry, so as to keep the inside of the body in a
dry state and prevent it from mildewing.
8.2. DISPOSAL
WARNING!
Releasing refrigerant into atmosphere is strictly forbidden!
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
OCEANIC
120-126Quai de Bacalan CS11584 33000Bordeaux
IMPORT BY:
A.M.C.
123,QUAI JULES GUESDE
94400 VITRY SUR SEINE
France
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>