ecostrad F0606 Opus Infrared Heating Panel Instruction Manual

June 15, 2024
Ecostrad

ecostrad F0606 Opus Infrared Heating Panel

ecostrad-F0606-Opus-Infrared-Heating-Panel-product

The Ecostrad Opus Infrared Heating Panel is a heating device designed to provide warmth and comfort in various spaces. It utilizes infrared technology to efficiently heat up the surroundings.

Warnings & Precautions

Before using or installing the device, it is important to read and understand the user manual. Keep the manual in close proximity to the device for future reference.

  • Warning: Do not mount the panels on the ceiling if they are specifically designed for wall mounting. Incorrect usage can lead to overheating and fire hazards.
  • Warning: The appliance can be used by children aged 8 years and above, as well as individuals with reducedphysical abilities or lack of experience, provided they are supervised and instructed on safe usage.
  • Warning: Children under 3 years old should be kept away from the appliance unless continuously supervised. Children aged 3 to 8 years old should only operate the appliance if it is properly installed and they have been given supervision and instruction on safe usage.
  • Warning: Do not use the device in enclosed spaces if there are individuals present who cannot leave the room independently and are not under constant supervision.
  • Warning: Do not leave the device unattended during operation.
  • Warning: Do not touch the device while in a bathtub or shower.

Technical Information
The technical specifications of the Ecostrad Opus Infrared Heating Panel are detailed in the user manual.

Supplied Parts
The package includes all necessary parts and components for the installation and operation of the heating panel. Refer to the user manual for a complete list.

Device Structure
The device is designed with safety features and specific surfaces that may become hot during and immediately after operation. Avoid touching these hot surfaces to prevent burns.

Installation
Follow the instructions provided in the user manual for proper installation of the Ecostrad Opus Infrared Heating Panel. Ensure the device is mounted securely and in the intended operating position.

Troubleshooting
If any issues or malfunctions occur with the device, refer to the troubleshooting section of the user manual for guidance on identifying and resolving problems.

Maintenance & Servicing
Regular maintenance and servicing are essential for optimal performance and longevity of the heating panel. Consult the user manual for recommended maintenance procedures and frequency.

Storage
When not in use, store the device in a clean and dry environment. Follow the storage instructions provided in the user manual to ensure proper preservation.

ErP Ecodesign Information
The user manual contains information regarding the ErP (Energy-related Products) Ecodesign requirements and compliance of the Ecostrad Opus Infrared Heating Panel.

Disposal
When disposing of the device, follow local regulations and guidelines for proper disposal methods. Do not dispose of it as regular household waste.

Ratings :
220 – 240 V~ AC 50 Hz, Class I, IP54

Symbols

  • Warning
    This symbol indicates a hazard with an average risk level which, if not avoided, could result in serious injury or death.

  • Warning of electrical voltage
    This symbol indicates danger to the life and health of persons due to electrical voltage.

  • Do not cover
    This symbol located on the device indicates that it is prohibited to place objects (such as towels, clothes etc.) above or directly in front of the device. To avoid overheating and fire hazards, the device must not be covered.

  • Hot surface
    This symbol located on the device indicates that its surfaces are hot during and immediately after operation. Hot surfaces should not be touched: danger of burns.

  • Do not spray
    This symbol located on the device indicates that it is prohibited to spray the device.

  • Observe instructions in manual
    This symbol located on the device indicates that instructions in the operating manual must be observed when installing and using the device.

About the Device

  • The device is designed to provide an efficient, comfortable, and healthy heating system for domestic or commercial properties.
  • Infrared heating panels can reduce air circulation and help to maintain a clean, silent, dust free environment.
  • Infrared panels are designed for indoor environments with normal heating requirements. They are ideal for homes, schools, hospitals and offices. They should not be used outdoors or in large internal spaces such as workshops or warehouses.
  • The Ecostrad infrared panel range is available in a wide range of sizes and styles.

Warnings & Precautions

Read this manual carefully before using or installing the device. Always store the manual in the immediate vicinity of the device or its site of use.
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire, serious injury, or all of the above. Save all warnings and instructions for future reference.

  • Warning
    Do not ceiling mount panels designed for wall mounting only.
    Use of panels in unspecified locations can cause panels to overheat and poses a fire risk.

  • Warning
    This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  • Warning
    Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate, or clean the appliance, or perform maintenance

  • Warning
    Do not use the device in enclosed spaces if persons are present who cannot leave the room independently and are not under constant supervision

  • Warning
    Some parts of this product can become very hot and cause burns. Do not install close to curtains or other combustible materials. Particular attention should be given where children and vulnerable adults are present. To avoid the possibility of injury, the following people should be particularly careful when using the heater: infants and children, the elderly, the disabled, people with medical conditions, people with sensitive skin, and people under the influence of alcohol, drugs, or sleeping pills.

Warning

  • Remove both protective films (on the front and on the back) before using.
  • Be sure the usage voltage is between 220-240V, 50Hz, and the power supply is strictly in accordance with IEC regulations. The device must be earthed.
  • Any socket used with the device must be at least 5A.
  • Do not use the device in rooms where contact with flammable or potentially explosive materials like dust, gas or vapour cannot be avoided.
  • Do not use in rooms or environments that have a corrosive atmosphere.
  • Set the device up in an upright and stable position.
  • Do not operate the device when wet. If the device gets wet during cleaning, allow it to dry out before using.
  • Do not use the device with wet or damp hands.
  • Do not expose the device to water jets.
  • Never insert fingers or objects into the device.
  • Do not cover the device during operation.
  • Do not transport the device during operation.
  • Do not sit on the device.
  • This appliance is not a toy. Keep away from children and animals. Do not leave the device unattended during operation
  • Check accessories and connection parts for possible damage prior to every use of the device. Do not use defective devices or device parts.
  • Ensure all electric cables outside of the device are protected from damage – e. g. from animals or furniture. Never use the device if electric cables or power connections are damaged.
  • The electrical connection must correspond to the specifications given in the technical information chapter (section 3).
  • Insert the mains plug into a properly secured mains socket.
  • Do not overload the socket used to power the device.
  • Do not plug into sockets behind the heater.
  • Observe the device’s power output, cable length and intended use when considering use of an extension cable. If an extension cable is used it should be fully unrolled; do not coil the cable. Avoid electrical overload. Do not create a hazard with trailing wires.
  • Before carrying out maintenance, care or repair work on the device, ensure the device is unplugged. Do not use the cable to tug the plug from the socket. Hold the plug by its housing and pull.
  • Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
  • Do not under any circumstances use the device if you detect damage to the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard. Defective power cables pose a serious health risk.
  • When installing the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the installation instructions (section 6).
  • Never drill into the heating device.
  • Do not use the device in close proximity to curtains or other flammable materials.
  • Do not touch the surface of the device during operation. The surface reaches high temperatures when in operation. Risk of burns.
  • Allow the device to cool down before touching or transporting the device, or attempting maintenance work.
  • Do not use this device near bathtubs, shower trays, swimming pools or other water containers. Risk of electric shock.
  • The device must be placed where the switches and controllers cannot be touched by a person in a bathtub or shower.

Technical Information

Heating element Carbon crystal
Heating method Far infrared heating
Voltage 220-240V/50Hz
Surface temperature Wall panels: approx. 85-95 °C

Ceiling panels: approx. 90-105 °C

Body material| Aluminium
IP rating| IP54 (excluding plug)
Overheat protection| Yes
Power cable length| 1.9m

Model Specifications

Model| Size (mm)| Power (W)| Voltage / Frequency| Rated Current (A)| Mounting Type
---|---|---|---|---|---
F0606| 595 x 595| 350| ****






220-240V

/ 50Hz

| 1.5 – 1.6| Wall only
F0706| 705 x 605| 450| 1.9 – 2| Wall only
F1006| 1005 x 605| 580| 2.4 – 2.6| Wall only
F1207| 1205 x 755| 900| 3.8 – 4.1| Wall only
F1209| 1205 x 905| 1100| 4.6 – 5| Wall only
F0606-C| 595 x 595| 270| 1.1 – 1.2| Ceiling or wall
F0706-C| 705 x 605| 320| 1.3 – 1.5| Ceiling or wall
F1006-C| 1005 x 605| 450| 1.9 – 2| Ceiling or wall
F1207-C| 1205 x 755| 700| 2.9 – 3.2| Ceiling or wall
F1209-C| 1205 x 905| 800| 3.3 – 3.6| Ceiling or wall
Warning

Do not ceiling mount panels designed for wall mounting only.

Use of panels in unspecified locations can cause panels to overheat and poses a fire risk.

Supplied Parts

ecostrad-F0606-Opus-Infrared-Heating-Panel-figf-
\(1\)

  • 1 x Heating Panel (A)
  • 4 x Screws (B)
  • 4 x Wall Plugs (C)
  • 1 x Drilling Template (D)
  • 1 x Control Guide
  • 1 x Installation Manual
  • 1 x Wall Mounting Kit

The kit provided should be used for wall mounting only. For ceiling installation, kits are available for both direct and suspended installation. Purchase a suitable kit before attempting ceiling-mounted installation. See instructions for both kits below.
The screws provided with the panel can be used for both mounting kits.

Device Structure

Component partsecostrad-F0606-Opus-Infrared-Heating-Panel-figf-
\(2\)

  1. Frameless aluminium shell
  2. Heating element
  3. Insulation layer
  4. Rear aluminium sheet
  5. Power cable
  6. Junction box
  7. Mounting bars

Installation

Warning – Remove protective films from back and front of panel before installing.

Wall Mounting Instructions
These instructions apply to wall mounting only. Turn to page 10 for ceiling mounting instructions.
If the device is being fitted in a bathroom, the unit must not be plugged in. The plug should be removed and the unit hardwired into a fused spur. This is a job for a qualified electrician.

Minimum distances

Front| 300mm
Left| 100mm
Right| 100mm
Top| 500mm

  1. Choose the mounting position, respecting the minimum distances from surrounding walls, ceilings or fixed objects listed in the table opposite. Minimum distances must be observed. Mounting closer than recommended creates a fire risk.
  2. Stick the drilling template on the wall. Drill the holes with an 8mm rotary bit.ecostrad-F0606-Opus-Infrared-Heating-Panel-figf- \(3\)
  3. Push the wall plugs (C) into the holes. Insert the screws (B) into the wall plugs. The screws should protrude approx. 5mm from the plugs.
  4. Hang the heating panel on the screws.ecostrad-F0606-Opus-Infrared-Heating-Panel-figf- \(4\)
  5. Slide the panel across so that the screws lock into their correct position in the  bracket, as pictured below:
  6. Plug the device into a power socket to begin using. Unplug when not in use.
    Note – if the device is fitted in a bathroom, the plug must be removed and the unit hardwired into a fused spur; this is a job for a qualified electrician.

Ceiling Mounting – Direct Method

This method should only be used with panels designed for ceiling mounting, when the kit below has been purchased:ecostrad-F0606-Opus-Infrared-Heating-
Panel-figf- \(6\)

Note : Mounting kit does not come with screws. Please use screws provided with the panel.
Note : Before ceiling installation, ensure you leave at least 30cm between the panel and surrounding walls, and at least 20cm from any lighting fixtures.

  1. Drill four holes on the ceiling, positioned as per the diagram below, according to the measurements given per size in the table below. You will need a 6mm drill bit.ecostrad-F0606-Opus-Infrared-Heating-Panel-figf- \(7\)
    Panel Size (mm)| Distance A (mm)| Distance B (mm)
    ---|---|---
    595 x 595| 310| 474
    905 x 605| 480| 474
    1205 x 605| 660| 474
    1205 x 905| 660| 704
  2. Push the wall plugs into the holes. Mount the four hanging brackets onto the ceiling, with the ends with the screw holes pointing outwards, as per the diagram above. Fix in place with screws. Turn the screws to the end tightly. This is important for a secure fitting.
  3. Take off all four plastic caps from the mounting bars on the back of the panel.ecostrad-F0606-Opus-Infrared-Heating-Panel-figf- \(9\)

Slide the panel onto the hanging brackets, as per the diagrams below. Slot the mounting bars onto the hanging brackets on one side. Raise the panel until it is level with the ceiling and pull it back so the mounting bars slot onto the other two brackets.ecostrad-F0606-Opus-Infrared-Heating-Panel-figf-
\(10\)

Ceiling Mounting – Suspended Method

This method should only be used with panels designed for ceiling mounting, when the kit below has been purchased:ecostrad-F0606-Opus-Infrared-Heating-
Panel-figf- \(11\)

Minimum and Maximum Suspension Lengths

Minimum (cm) Maximum (cm)
4.5 100

Note : Measurements are from the ceiling to the back of the panel.

Components

ecostrad-F0606-Opus-Infrared-Heating-Panel-figf-
\(12\)

  • 1 x Heating Panel (A)
  • 4 x Panel Caps (B)
  • 4 x Wire Caps (C)
  • 4 x Ceiling Lock Screws (D)
  • 4 x Ceiling Lock Heads (E)
  • 4 x Long Screws (F)
  • 4 x Short Screws (G)
  • 4 x Expansion Plugs (H)
  • 4 x Suspension Wires (I)

Note : Before ceiling installation, ensure you leave at least 30cm between the panel and surrounding walls, and at least 20cm from any lighting fixtures.

  1. Push short screws (G) into panel caps (B) and screw into the holes on the back of the panel.ecostrad-F0606-Opus-Infrared-Heating-Panel-figf- \(13\)
  2. Thread suspension wires (I) through wire caps (C). Screw (C) onto (B).ecostrad-F0606-Opus-Infrared-Heating-Panel-figf- \(14\)
  3. Drill four 6mm holes in the ceiling, using a 6mm drill bit. Fix the four expansion plugs (H) into the holes.ecostrad-F0606-Opus-Infrared-Heating-Panel-figf- \(14\)
  4. Insert the four long screws (F) into ceiling lock heads (E) and screw tight into the expansion plugs (H).
  5. Attach ceiling lock screws (D) to suspension wires. Screw (D) tight into (E).
  6. To adjust the length of the suspension wire, hold down the catch on the ceiling lock heads and feed the wire through the gap in the lock head. Release the catch and the wire will lock automatically in your chosen position. You can remove any excess wire with wire cutters if you wish.

Troubleshooting

Problem Possible Cause Action
Noise from the panel when it is first heating up. Expansion sounds from the
panel as its structure adapts to being heated for the first time. This is

normal. The device will stop making noise after it has been in use for some time.
The surface of the device is slightly raised.| Expansion of the surface material when used for the first time.| This is normal.
The surface of the device heats up but doesn’t get to full temperature.| Two possible causes:

1.  Voltage is too low.

| ****

1.  Contract an electrician to install a voltage regulator.

2. The room where the panel is hung is very cold.| 2. This is normal. Give the panel plenty of time to heat up, and make sure you have fitted a suitable number of panels for the room size and heat loss profile.

Maintenance & Servicing

Before starting maintenance:

Warning of electric voltage

  • Allow the device to cool down completely.
  • Do not touch the mains plug with wet or damp hands.
  • Hold onto the mains plug when pulling the power cable out of the mains socket.
  • Tasks which require the housing to be opened must only be carried out by authorised specialist bodies.

Cleaning the device:

Warning of electric voltage

  • Allow the device to cool down completely before cleaning.
  • Never immerse the device in water!
  • Clean the device with a soft, damp and lint-free cloth.
  • Ensure that no moisture enters the housing. Protect electrical components from moisture.
  • Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners.
  • Wipe the housing dry after cleaning. Allow the device to dry before using.

Storage

When the device is not being used, observe the following storage conditions:

  • Store in an upright position, out of direct sunlight.
  • Store in a dry environment, protected from frost and heat.
  • Protect against dust, using a cover if necessary.
  • To prevent damage, do not store other objects on top of the device.

ErP Ecodesign Information

| Heating capacity| Auxiliary current consumption
---|---|---




Model

| ****

Nominal heat output

(Pnom / KW)

| Minimum heat output (indicative)

(Pmin / KW)

| Maximum continuous heat output

(Pmax.c / KW)

| ****

At nominal heat output

(elmax / KW)

| ****

At minimal heat output

(el/ KW)

F0606| 0.4| N/A| 0.4| 0.365| N/A
F0706| 0.4| N/A| 0.4| 0.418| N/A
F1006| 0.6| N/A| 0.6| 0.608| N/A
F1207| 0.9| N/A| 0.9| 0.942| N/A
F1209| 1.0| N/A| 1.0| 1.048| N/A
F0606-C| 0.3| N/A| 0.3| 0.282| N/A
F0706-C| 0.3| N/A| 0.3| 0.335| N/A
F1006-C| 0.4| N/A| 0.4| 0.470| N/A
F1207-C| 0.7| N/A| 0.7| 0.732| N/A
F1209-C| 0.8| N/A| 0.8| 0.836| N/A

Information requirements for electrical local space heaters

Item Unit

Type of heat input, for electric storage local space heaters only (select one)
manual heat charge control, with integrated thermostat| N/A
manual heat charge control with room and/or outdoor temperature feedback| N/A
electronic heat charge control with room and/or outdoor temperature feedback| N/A
fan assisted heat output| N/A
Type of heat output/room temperature control (select one)
single stage heat output and no room temperature control| [no]
Two or more manual stages, no room temperature control| [no]
with mechanic thermostat room temperature control| [no]
with electronic room temperature control| [no]
electronic room temperature control plus day timer| [no]
electronic room temperature control plus week timer| [yes]
Other control options (multiple selections possible)
room temperature control, with presence detection| [no]
room temperature control, with open window detection| [no]
with distance control option| [no]
with adaptive start control| [yes]
---|---
with working time limitation| [no]
with black bulb sensor| [no]

Disposal

The icon with the crossed-out waste bin on electrical or electronic equipment stipulates that this equipment must not be disposed of with household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your local authority.
The separate collection of waste electrical and electronic equipment enables the re-use, recycling and other forms of recovery of waste equipment, and prevents any negative effects for the environment or human health caused by the disposal of hazardous substances potentially contained in the equipment.

For queries contact:

The UK manufacturer
Ecostrad Ltd. Firecrest House Lingerfield Business Park Market Flat Lane Knaresborough North Yorkshire HG5 9JA

The ROI Importer
Ignition Heatco Ireland Limited Unit 282 Block G Blanchardstown Corporate Park 2 Dublin Republic of Ireland D15 R65X

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Ecostrad User Manuals

Related Manuals