SPACE-RAY Sura Electric High Intensity Halogen Instruction Manual

June 15, 2024
SPACE-RAY

SPACE-RAY Sura Electric High Intensity Halogen

SPACE-RAY-Sura-Electric-High-Intensity-Halogen-fig-1

Product Information

The Electric High Intensity Halogen Model Sura is an IP55 rated heater designed for general, local, and spot heating. It operates using the principle of radiant heat transfer, similar to the sun, by heating objects directly without heating up the air in between. The heater consists of various components, including a protective wire guard, quartz lamp holders and quartz lamp, reflector, hard case and end caps, connector box, wall hanger bracket with fixing screws, and electric cable. All components are manufactured according to EU directives and bear the CE marking.

Product Usage Instructions

Important Safety Information
Before installing or using the heater, ensure that your electricity supply (capacity, earth, protection) is checked by authorized personnel. The manufacturer is not responsible for any damage caused by improper installation or usage of the product. Refer to the table below for the minimum height from floor level for installed products:

Model Power Electrical Supply Current Min Height from Floor Dimensions
GSS20 2kW 230V 8.25A 2.5m 430x166x95
GSS40 4kW 230V 17.4A 3.5m 830x166x95

Installation

  1. Fix the hanger bracket to the desired location (wall, column, or beam) where you want to install the heater.
  2. Use a spirit level to ensure that the heater is installed straight.
  3. Mark the location of the hanger fixing holes on the mounting surface.
  4. Drill the correct sized hole and insert the supplied plastic wall plugs.
  5. Fix the hanger bracket in place using the supplied screws.

Using the Heater
To use the heater:

  • Do not touch the lamp(s) with bare hands. If you touch the lamp(s), clean the fingerprints with a soft and dry cloth using a volatile solvent such as alcohol.
  • Avoid using the heater in environments where it can be exposed to water or stored improperly.
  • Ensure that electrical connections are made by authorized personnel according to the instructions and wiring diagram provided.
  • No de-assembly of any part of the device is required for electrical connection.

Removing the Heater
To remove the heater, follow the reverse steps of the installation process.

The Heater

  • According to Thermodynamic Laws there are three types of heat transfers: conduction, convection and radiation.
  • “Radiant Heaters” function using the radiant heat trans-fer principle, they act like the sun by heating the objects that they are exposed to. In other words, with radiant heating the objects, people, etc. are heated directly by a solid surface without heating up the air in between.
  • The air warms up afterwards, by the convection heat released from the people and objects.
  • It is possible to divide the radiant heaters in to two main classes. These are “Low Intensity Heaters”, “High and Medium Intensity Heaters”. SPACE-RAY SURA models belong to the latter.
  • Each heater has a halogen electric lamp. The filament of these lamps reaches up to 1200°C, a short time after switching on. Thus, a comfortable warm feeling occurs just after start up. These characteristics of the heater provide economical and effective heating solutions for applications that are very high and wide, have poor insu-lation and outdoors. Additionally, they are clean, odor-less, silent and environmental friendly.
  • SPACE-RAY™ SURA heaters can be used as general, local or spot heating appliances.
  • All the equipment used in the production of the heaters are manufactured according to the EU directives, having the CE marking.

Product Components

The main product components are as follows:

  • A. Protective wire guard
  • B. Quartz lamp holders and quartz lamp
  • C. Reflector
  • D. Hard case and end caps
  • E. Connector Box
  • F. Wall hanger bracket c/w fixing screws
  • G. Electric cable

Instructions For Installation & Use

Important safety information

  • Please read this information carefully before installing and using this device, which is manufactured to use for general, local and spot heating.
  • This device should not be used in the environments where;
    • There are flying or jumping animals
    • Explosive or flammable goods are manufactured or stored.
  • Do not touch the lamp(s) with bare hands. If you touch the lamp(s) clean the fingerprints with a soft and dry cloth with the help of a volatile Solvent such as alcohol. Otherwise, these fingerprints will reduce the life of the lamp(s) and/or cause failure.
  • Electrical connections should be made by authorized personnel according to these instructions and the wiring diagram show on page 4.
  • It is not necessary to de-assemble of any part of the device to make the electrical connection. The connection should only be made according to the instructions and schematics given below.
  • Please have your electricity supply (capacity, earth, protection) checked carefully by authorized personnel before installing it. The manufacturer is not responsible any damage caused due to the installation or usage of this product other than described within this manual.
  • The below table shows the minimum height from floor level for installed products:

SPACE-RAY-Sura-Electric-High-Intensity-Halogen-fig-2

Installation

  • The parts needed to install the product are provided within the box given to you. Please follow the instruc-tions given below:
  • Fix the hanger bracket to the place (wall, column or beam) where you want to install the heater.
  • Use a spirit level to ensure the heater is installed straight. Mark the location of the hanger fixing holes on the mounting surface, and drill the correct sized hole. Insert the plastic wall plugs (suuplied) and fix the hanger brack-et in place using the screws supplied.
  • Please note, if fixing to a non-brick or concrete surface then please source and use the correct fixings required for the surface.
  • Angle of the heater can be adjusted by loosening the screws on the hanger bracket, selecting your preferred angle and re-tightening the screws.
  • Please make sure that the electrical connection of the heater is made according to the instructions and wiring details contianed within this document.
  • The operation of the heater is made by switching on or off the electrical supply when the heater is required/not required. This can be via a conventional three pin plug fitted into a wall socket, or hard wired into a fused isolator. It is also possible to use a thermostat and/or a dimmer as an option. Please contact your local repre-sentative or service agent for these items.
  • Do not install the heater directly under the wall plug/isolator.

Wiring Diagram

SPACE-RAY-Sura-Electric-High-Intensity-Halogen-fig-3

Use

  • It is always necessary to make sure that the installation of the heater is properly made and the electricity current provided is not below or above permissible the limits. Products which are installed correctly should serve you for a long time.
  • Please pay attention to the following when using this heater:-
    • Please check if the heater is installed properly according to the rules (descriptions and warnings) given in the instruction manual.
    • When using models supplied with a plug, just con-nect the plug to a wall terminal with convenient grounding.
    • Turn on the on/off switch when using un-plugged models.
    • Disconnect the electric supply if the heater is not used.
    • Fluctuations in the electric voltage will reduce the lamp life. Please make sure that the fluctuations do not occur.
    • Each heater has a wire guard at the front to protect the heating elements being touched by anything. Do not operate the heater when the protective guard is not present.
    • Do not insert anything into the heater and do not touch the lamp.
    • Stay 1.25 m away from the heater when it is on.
    • Prolonged looking at the lamp during operation may result in damage to the eye. Therefore when the heater is on, do not look at the lamp with bare eyes.
    • Protect the heater against movement and vibrations even when it is not operating.
    • Do not put anything on the heater or cover it fully or partially.
    • Ensure that combustible items such as paper, ny-lon curtains etc.. are at least 1.25 m away from the heater.
    • Ensure that children cannot reach the heater.
  • If the heater is not working:
    • Do not try to fix the heater.
    • Disconnect the electric supply.
    • Contact the nearest authorized agent for maintenance.
  • The reflectors are made out of highly polished aluminum. They do not lose their reflectivity easily, even due to dirt and dust. Therefore, it is not necessary to clean them fre-quently. However, if needed please follow the procedure below to clean the reflectors.
    • Disconnect the electric supply to the heater.
    • Remove the protective guard.
    • Clean the reflector with a dry cloth.
    • Do not touch the lamp with bare hands during cleaning. Make sure that no stain occurs on the lamp.
    • If the lamp gets dirty clean the lamp with a soft cloth moisturized with alcohol.
    • Install the protective guard.
    • Connect the heater to the electric supply.

Removing The Heater

To uninstall the heater, follow the procedure below:

  • Ensure the heater is switched off and is not hot.
  • If the heater does not have a plug, authorized personnel must remove the electric wiring according to local codes.
  • If the heater has plug connection, simply disconnect the heater from the wall socket.
  • Hold the heater case (it is recommended that this is done by another person) and loosen the screws at the sides of the heater hanger bracket. Be careful when removing the wall fixing screws ensuring that the heater is firmly grasped.
  • Cover the heater with impact absorbing wrapping before packing to protect the heater from any damage.