BEA 75.5611.03 HIGH-MOUNT Unidirectional Activation Sensor Instruction Manual
- June 13, 2024
- BEA
Table of Contents
EAGLE HIGH-MOUNT
Unidirectional activation sensor for automatic, industrial doors
Visit website for available languages of this document.
https://www.qrfy.com/F-ZqkgojmZ
DESCRIPTION
TECHNICAL SPECIFICATIONS
Technology: | microwave and microprocessor |
---|---|
Transmitter frequency: | 24.150 GHz |
Transmitter radiated power: | < 20 dBm EIRP |
Transmitter power density: | < 5 mW/cm² |
Detection mode: | motion |
Min. detection speed: | 2 in/s |
Supply voltage: | 12 – 24 VAC ±10%; 12 – 24 VDC +30% / -10% |
Mains frequency: | 50 – 60 Hz |
Max power consumption: | < 2 W |
Output:
max. contact voltage:
max. contact current:
max. switching power:| relay (free of potential changeover contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC)
Mounting height:| 10’ − 16’6″
Degree of protection:| IP54
Temperature range:| -4 – 131 °F
Dimensions:| 4.7″ (L) × 3.1″ (H) × 2.0″ (W)
Tilt angles:| 0 – 90° vertical; -30 – 30° lateral
Material:| ABS
Weight:| 7.6 oz
Cable length:| 30’
Norm conformity:| R&TTE 1999/5/EC, LVD 2006/95/EC, RoHS 2 2011/65/EU
Specifications are subject to change without prior notice.
All values measured in specific conditions.
INSTALLATION TIPS
- Do not touch electrical parts.
- Avoid vibrations.
- Do not cover the sensor.
- Avoid proximity to neon lamps or moving objects.
- The sensor may be mounted horizontally or vertically (e.g. on a ceiling or on a wall, respectively).
◊ If mounting horizontally, the sensor must be mounted in front of the door.
◊ If mounting vertically, the sensor must be mounted above the door.
How to Open the Sensor:
MOUNTING & WIRING
If using EAGLE SPACER or EAGLE SPACER V, please refer to User’s Guide 75.5981 before beginning.
Apply the mounting template.
Drill 1 hole for the cable and
pull it through.
Drill 2 holes for the screws.| Connect the wires accordingly:
1: RED – POWER SUPPLY +
2: BLACK – POWER SUPPLY 3: WHITE -COM
4: GREEN – NO OR
5: GREEN – NC| Position the cable as indicated.
Mount the sensor firmly.
If desired, adjust the antenna angle (laterally and/or vertically) to position
the detection field.
When mounting at the maximum height, BEA recommends a 15° tilt angle.
LATERAL ADJUSTMENT
VERTICAL ADJUSTMENT
SETTINGS (by remote control or push-buttons)
Program the sensor for the desired application.
When mounting at the maximum height, BEA recommends the following:
Immunity = low
Zone Size = XXL
RESETTING TO FACTORY VALUES
ACCCESS CODE
The access code (1 to 4 digits) is recommended to set sensors installed close
to each other.
Once you have saved an access code, you always need to enter this code to
unlock the sensor.
If you forget the access code, cycle the power. For the first minute, you can
access the sensor without an access code.
TROUBLESHOOTING
The door remains closed.
LED is off.| Sensor power is off.| Check wiring and power supply.
---|---|---
Door control setting (F2) is set to 3 (closed).| Change door control setting
(F2) to 1 (automatic).
Door does not react as expected| Improper output configuration on sensor.|
Change the output configuration setting
on each sensor connected to the door
operator.
Door opens and closes constantly| Sensor is disturbed by door motion or
vibrations from door motion.| Ensure sensor is fixed properly.
Ensure detection mode is unidirectional.
Increase antenna angle.
Increase immunity filter.
Reduce zone size.
Door opens for no discernable reason| It rains and the sensor detects the
motion of the rain drops.| Ensure detection mode is unidirectional.
Increase immunity filter.
Install rain accessory.
Change the antenna angle.
Reduce zone size.
Increase immunity filter.
Change the antenna angle.
Increase immunity filter.
In highly reflective environments, the sensor detects objects outside of its
detection zone.
In airlock vestibules, the sensor detects the movement of the opposite door.
LED flashes quickly after unlocking| Sensor needs access code to unlock.|
Enter correct access code.
If you forgot the code, cycle the power to access the sensor without access
code.
Change or delete the access code.
Sensor does not respond to the remote control| Batteries in the remote control
are weak or installed improperly.| Check batteries and change if necessary.
Remote control not pointed correctly.| Point remote control at sensor.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect
installations or incorrect adjustments of the sensor/device; therefore, BEA,
Inc. does not guarantee any use of the sensor/device outside of its intended
purpose.
BEA, Inc. strongly recommends that installation and service technicians be
AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk
assessment following each installation/service performed, ensuring that the
sensor/device system performance is compliant with local, national, and
international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the
door/gate shall be performed per the door/gate manufacturer’s recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry
practices. Safety inspections must be performed during each service call –
examples of these safety inspections can be found on an AAADM safety
information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and
International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are
in place.
Tech Support & Customer Service:
1-800-523-2462
General Tech Questions: techservices-us@BEAsensors.com | Tech Docs:
www.BEAsensors.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>