iPower GLFANXINLINE8 Inline Fan Instructions
- June 13, 2024
- IPOWER
Table of Contents
iPower GLFANXINLINE8 Inline Fan
Product Information
The iPower Inline Fan is a high-quality ventilation fan designed for indoor use. It is composed of a chassis, impeller, external rotor motor, and junction box. The chassis is made of cold-rolled steel treated with a plastic sealant to resist corrosion. The flow channel design of the impeller allows for maximum efficiency and airflow while minimizing noise. The external rotor motor is attached directly to the impeller to further reduce noise and provide high airflow. The junction box is located externally for easy service and removal.
The fan comes in various sizes with different specifications:
- Chassis Diameter: 100mm, 125mm, 150mm, 160mm, 200mm, 250mm, 315mm
- Impeller Diameter: 190mm, 220mm, 250mm
The fan operates at different parameters depending on the model:
Model| Voltage (V)| Frequency (Hz)| Input Power (W)| Air Velocity (CFM)| Speed
(rpm)| Noise (dB)| Insulation Class| Weight (Kg)| Static Pressure (Pa)
---|---|---|---|---|---|---|---|---|---
F4| 74| 190| 2460| 65| 3.1| 360| F| 6.6| 570
F6| 95| 442| 2380| 65| 5.6| 350| F| 6.6| 533
F8| 110| 60| 137| 745| 2600| 69| F| 6.6| 570
F10| 174| 862| 2390| 70| 6.6| 533| F| 7.0| 704
F12| 290| 1060| 2378| 71| 7.0| 704| F| 7.0| 704
Product Usage Instructions
Before using the iPower Inline Fan, it is recommended to follow these instructions:
- Install air filters and one-way valves on the fan’s inlet and outlet to extend the fan’s life.
- Mount the circular fan indoors using non-adhesive materials.
- Keep the fan clean from dust and foreign contaminants.
- Connect both ends of the fan to the pipeline.
Note: For repairs and maintenance, please refer to the user manual provided by the manufacturer.
Warning: Follow all safety precautions and guidelines provided in the user manual to ensure safe usage of the product.
Overview
The iPower Inline Fan, an addition to the iPower family, utilizes the newest and advanced technology to offer an affordable air movement solution. The iPower Inline Fan features high efficiency centrifugal impeller and a high performance external rotor motor. The compact, lightweight, and powerful motor generates high rate of air flow with minimal vibration and noise, which prolongs the inline fan’s service life. It’s versatile and compact design allows easy and flexible installation. Not just used in indoor gardens and greenhouses, the iPower inline fan can be found in hotels, halls, meeting rooms, supermarkets, railway stations, airports and other public areas that require positive ventilation.
Product Structure
- The iPower Inline Fan is composed of the chassis, impeller, external rotor motor, and junction box.
- Chassis: Is made of a high-quality, cold-rolled steel. The surface is treated with a plastic sealant to provide a strong resistance to corrosion. CAD optimizations on the flow channel design to allow the impeller perform at its greatest efficiency. Inlet and outlet diameter flanges are easy to install, repair and clean. Specifications: φ100mm, φ125mm, φ150mm, φ160mm, φ200mm, φ250mm, φ315mm.
- Impeller: diameter φ190mm, φ220mm, φ250mm. The curved-end blade impeller works with the fan casing in harmony; the fan can produce maximum air flow and efficiency while minimizing noise.
- External Rotor Motor: A single-phase asynchronous external rotor motor is located on the chassis. The impeller is attached directly to the rotor motor by die-casting. The impeller is driven directly by rotor to minimize noise while providing high airflow and extending service life.
- Junction box: The flame-retardant ABS plastic provides fireproof performance and is safe to use. The external location of the junction box allows for easy service and removal.
Dimensions
- A— Air outlet and inlet diameter
- B— Cylindrical chasse diameter of
- C— The length of a draft
- D— The total length of chasse
- E— Length of air inlet
Model | ΦA | ΦB | C | D | E | Specification(mm) |
---|---|---|---|---|---|---|
F4 | 95 | 268 | 22 | 200 | 22 | 190 |
F6 | 145 | 268 | 30 | 269 | 25 | 225 |
F8 | 195 | 342 | 30 | 269 | 50 | 250 |
F10 | 250 | 342 | 30 | 279 | 50 | 250 |
F12 | 300 | 400 | 30 | 295 | 50 | 280 |
Operating Parameters
Model| Voltage (V)| Frequency (Hz)| Input Power (W)| Air velocity (CFM)| Speed
(rpm)| Noise (dB)| Insulation class| Weight(Kg)| Static(pa)
---|---|---|---|---|---|---|---|---|---
F4| 110| 60| 74| 190| 2460| 65| F| 3.1| 360
F6| 95| 442| 2380| 65| 5.6| 350
F8| 137| 745| 2600| 69| 6.6| 570
F10| 174| 862| 2390| 70| 6.6| 533
F12| 290| 1060| 2378| 71| 7.0| 704
Schematic wiring diagram
Installation & Troubleshooting
- Mount the fan on a stable platform via mounting brackets.
- Slide the mounting clamps over air duct
- Slide the air duct onto the flanges on the fan
- Tighten the clamps down with a flat-head screwdriver or a hex socket.
- Plug the 110V plug into a wall outlet to turn on the fan.
If the product had been in storage for more than six months, insulation
resistance must be tested before use. Resistance to ground should be 20MΩ or
more. Before starting the fan, use your hands to drive the impeller to ensure
smooth impeller rotation without obstruction. After connecting the power,
observe the impeller rotation direction to be in the same direction with the
nameplate. After confirming everything is functioning properly, leave it
running for half an hour (30 minutes) to test the whether motor will have
issues with overheating or undesirable noises. If the fan does not exhibit any
signs of abnormal operations, it is safe to use and install.
To extend fan life, it is recommended that air filters and one-way valves be
installed on the fan’s inlet and outlet. The circular fan must only be used
indoors and be mounted with non-adhesive materials. Keep fan clean from dust
and foreign contaminants. Both ends of the fan must be connected to the
pipeline.
Repairs and Maintenance Notes
Under normal operating conditions, the fan should be cleaned every six months. Clean any dirt that may have accumulated inside the chassis and dust on the impeller, etc. Do not use water or any other liquid cleaning agent; use only a clean brush or a clean dry cloth to wipe away any loose dirt or dust. Proper cleaning ensures the fan operates at maximum efficiency against the impact of dust without impacting airflow. If it is used in environments that contain heavy dust, cleaning should occur more often to prevent the accumulation of dust that would impact normal operations.
Disassembly of the fan is extremely convenient.
- Remove the metal clamps from the flanges
- Remove the duct from the fan
- Dismount the fan from the mounting surface
- Remove the four screws that holds the fan housing
- Remove the junction box screw
- Remove 4 screws from the mounting bracket.
Warning
- Please read this manual carefully before installing.
- The fan’s motor power is multiplied by the shaft power factor of the specific operating conditions. In order to prevent electrical overload, please DO NOT obstruct the inlet or outlet airflow as the motor is running.
- Avoid impact or physical damage of the unit as it will cause premature failure.
- Keep fan in a dry environment.
- In the transmission of air, or any other non-corrosive medium, inlet temperature must not exceed 80C. The amount of dust and other solid contaminants should not exceed 100g per cubic meter. Avoid viscosity and fiber material.
- This product is covered under 12 month manufacturer’s warranty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>