Rheem RP16 Classic Series Heat Pump Instruction Manual

June 13, 2024
Rheem

Rheem RP16 Classic Series Heat Pump

Product Information

RP16 Air Conditioner/Heat Pump
The RP16 is a high-performance split system air conditioner and heat pump designed for optimal cooling and heating. It is Energy Star certified when matched with appropriate coil components. For more details, visit www.energystar.gov or consult your contractor.

Features and Benefits

  • Standard Features
  • Available Models
  • General Data/Electrical Data
  • Weighted Sound Power

Model Number Identification
The RP16 is available in the following models

  • RP1636AJ2NA – 18,000 BTU/HR (5.28 kW)
  • RP1660AJ2NA – 24,000 BTU/HR (7.03 kW)
  • RP1648AJ2NA – 30,000 BTU/HR (8.79 kW)
  • RP1624AJ2NA – 36,000 BTU/HR (10.55 kW)
  • RP1648AJ2NANOM – 42,000 BTU/HR (12.31 kW)
  • RP1624AJ2NANOM – 48,000 BTU/HR (14.07 kW)
  • RP1636AJ2NANOM – 60,000 BTU/HR (17.58 kW)
  • RP1660AJ2NANOM – 60,000 BTU/HR (17.58 kW)

General Data/Electrical Data
The RP16 requires a line voltage of 208/230 volts at 1 phase and 60 Hz. The maximum overcurrent protection amps and minimum circuit ampacity are as follows

  • RP1624AJ – 30 amps / 20 amps
  • RP1636AJ – 40 amps / 25 amps
  • RP1648AJ – 50 amps / 31 amps
  • RP1660AJ – 60 amps / 38 amps

The compressor, condenser fan motor, and other electrical data can be found in the complete user manual.

Weighted Sound Power
The RP16 is equipped with accessories such as a compressor crankcase heater, compressor hard start kit, compressor sound cover, high pressure control, low ambient control, and low pressure control. The weighted sound power level for each model is as follows

  • RP1624A – 71 dBa
  • RP1636A – 76 dBa
  • RP1648A – 74 dBa
  • RP1660A – 75 dBa

Product Usage Instructions

  1. Proper sizing and installation of the RP16 is crucial for optimal performance. It should be matched with appropriate coil components to meet Energy Star requirements. Consult your contractor for more information.
  2. Before installation, ensure that you have selected the correct model based on your cooling/heating needs. Refer to the available models section in the user manual for more details.
  3. Check the general data/electrical data section in the user manual for the line voltage requirements and maximum overcurrent protection amps for your specific model. Make sure your electrical system meets these requirements.
  4. Install the RP16 according to the clearances specified in the unit dimensions section of the user manual. Follow all local building codes and regulations during installation.
  5. Connect the control wiring as per the instructions provided in the control wiring section of the user manual. Ensure proper connections and secure wiring.
  6. Refer to the refrigerant line size information in the user manual to determine the appropriate size for your installation. Follow industry standards and guidelines for refrigerant line installation.
  7. Once installed, refer to the performance data section for information on the cooling and heating capabilities of the RP16. This will help you understand its performance under different conditions.
  8. The RP16 comes with a limited warranty. Refer to the warranty section in the user manual for details on coverage and terms.
  • Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.

Standard Feature Table

Features and Benefits

General Data

Physical Data Mismatches found. Please go to
https://my.rheem.com/static/private/POC/SpecSheets/AC/heatpumps.html?ssid=3eab55d0- fda4-412a- bb701277f744dcb0&id=d5738741-8e14-4b38-a571-7fd152541abe
Electrical Data
Model No.| RP1624AJ| RP1636AJ| RP1648AJ| RP1660AJ
Line Voltage Data (V olts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
MaximumOvercurrentProtectionAmps1| 30| 40| 50| 60
MinimumCircuitAmpacity1| 20| 25| 31| 38
Compressor
CompressorRatedLoadAmps1| 0| 0| 0| 0
CompressorLockedRotorAmps1| 0| 0| 0| 0
Condensor Fan Motor
CondenserFanMotorFullLoadAmps1| 2.8| 2.8| 1.4| 1.4
CondenserFanMotorLockedRotorAmps1| 0| 0| 0| 0

  • ¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
  • ²HACR type circuit breaker of fuse.
  • **** ³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories

RP1624A

Accessory Type| Part Number
RP1636A
Accessory Type| Part Number
RP1648A
Accessory Type| Part Number
RP1660A
Accessory Type| Part Number
Compressor crankcase heater| 44-17402-44
Compressor hard start kit| SK-A1
Compressor sound cover| 68-23427-26
High pressure control| Factory Standard
Low ambient control| RXAD-A08
Low pressure control
| Factory Standard

Weighted Sound Power Level (dBA)

Unit Size – Voltage, Series| Standard

Rating (dBa)

| Typical Octave Band Spectrum (dBA without tone adjustment)
---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
RP1624A| 71| 0| 0| 0| 0| 0| 0| 0
RP1636A| 76| 0| 0| 0| 0| 0| 0| 0
RP1648A| 74| 0| 0| 0| 0| 0| 0| 0
RP1660A| 75| 0| 0| 0| 0| 0| 0| 0
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

Unit Dimensions

  • Unit Dimensions Mismatches found.

Please go to https://my.rheem.com/static/private/POC/SpecSheets/AC/heatpumps.html?ssid=3eab55d0-fda4 -412a- bb70-1277f744dcb0&id=d5738741-8e14-4b38-a571-7fd152541abe

No Unit Dimensions Image Found.

CLEARANCES
No Clearance Image Found.

Control Wiring
No Control Wiring Image Found.

Application Guidelines

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
  2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C)
  3. Maximum outdoor operating air temperature is 125°F (51.7°C).
  4. For reliable operation, unit should be level in all horizontal planes.
  5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  6. Do not apply capillary tube indoor coils to these units.
  7. Factory – supplied filter drier must be installed.

Refrigerant Line Size Information

13-16 SEER Single-Stage Air-Conditioners

Unit Size| Allowable

Liquid Line Size

| Allowable

Suction Line Size

| Apply Long Line Guidelines if Linear Line Length

Exceeds Those Shown Below (Feet)

| Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150| 151-175| 176-200| 201-225| 226-250
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
1.5 Ton
See Note 3| 1/4″| 5/8″| N/A| N/A| N/A| N/A| 25/1.0| 50/.99| 62/.98| 43/.98| 24/.97| 5/.97| NR| NR| NR| NR
5/16″| 5/8″| N/A| 223| 198| 188| 25/1.0| 50/.99| 75/.98| 98/.98| 93/.97| 88/.97| 83/.96| 78/.96| 73/.95| 68/.94
3/8″| 5-8″| 178| 148| 132| 125| 25/1.0| 50/.99| 75/.98| 100/.98| 100/.97| 100/.97| 100/.96| 100/.96| 100/.95| 100/.94
1/4″| 3/4″| N/A| N/A| N/A| N/A| 25/1.0| 50/.99| 62/.98| 43/.98| 24/.97| 5/.97| NR| NR| NR| NR
5/16″| 3/4″
| N/A| 223| 198| 188| 25/1.0| 50/.99| 75/.98| 98/.98| 93/.97| 88/.97| 83/.99| 78/.98| 73/.98| 68/.98
3/8″| 3/4″| 178| 148| 132| 125| 25/1.0| 50/.99| 75/.98| 100/.98| 100/.97| 100/.97| 100/.99| 100/.98| 100/.98| 100/.98
2 Ton| 1/4″| 5/8″| N/A| N/A| N/A| N/A| 25/.99| 50/.98| 21/.97| NR| NR| NR| NR| NR| NR| NR
5/16″| 5/8″| 243| 213| 193| 175| 25/.99| 50/.98| 75/.97| 87/.96| 77/.95| 69/.94| 61/.93| 53/.92| 45/.91| 37/.90
3/8″| 5/8″| 162| 142| 128| 117| 25/.99| 50/.98| 75/.97| 100/.96| 100/.95| 100/.94| 98/.93| 95/.92| 92/.91| 89/.90
1/4″| 3/8″| N/A| N/A| N/A| N/A| 25/1.00| 50/1.00| 21/.99| NR| NR| NR| NR| NR| NR| NR
5/16″| 3/4″| 243| 213| 193| 175| 25/1.00| 50/1.00| 75/.99| 87/.99| 77/.98| 69/.98| 61/.98| 53/.97| 45/.97| 37/.96
3/8″| 3/4″| 162| 142| 128| 117| 25/1.00| 50/1.00| 75/.99| 100/.99| 100/.98| 100/.98| 98/.98| 95/.97| 93/.97| 37/.96
2.5 Ton| 5/16″| 5/8″| N/A| N/A| 133| 110| 25/.99| 50/.98| 75/.96| 70/.94| 59/.93| 48/.91| 36/.90| NR| NR| NR
3/8″| 5/8″| 142| 117| 88| 73| 25/.99| 50/.98| 75/.96| 100/.94| 98/.93| 94/.91| 90/.90| NR| NR| NR
5/16″| 3/4″| 213| 175| 133| 110| 25/1.00| 50/.99| 75/.99| 70/.98| 59/.98| 48/.97| 36/.96| 25/.96| 13/.95| NR
3/8″| 3/4″| 142| 117| 88| 73| 25/1.00| 50/.99| 75/.99| 100/.98| 98/.98| 94/.97| 90/.96| 86/.96| 82/.95| 78/.95
3 Ton| 5/16″| 5/8″| N/A| N/A| N/A| N/A| 25/.99| 50/.97| 66/.94| 49/.92| 32/.90| NR| NR| NR| NR| NR
3/8″| 5/8″| 108| 85| 90| 82| 25/.99| 50/.97| 75/.94| 95/.92| 89/.90| NR| NR| NR| NR| NR
5/16″| 3/4″| N/A| 128| 135| 123| 25/1.0| 50/.99| 66/.98| 49/.98| 32/.97| 15/.96| NR| NR| NR| NR
3/8″| 3/4″| 108| 85| 90| 82| 25/1.00| 50/.99| 75/.99| 95/.98| 89/.97| 84/.96| 78/.95| 72/.92| 67/.93| 61/.93
1/2″| 3/4″| 54| 43| 45| 41| 25/1.00| 50/.99| 75/.98| 100/.98| 100/.97| 100/.96| 100/.95| 100/.92| 100/.93| 100/.93
5/16″| 7/8″| N/A| 128| 135| 123| 25/1.00| 50/1.00| 66/1.00| 49/.99| 32/.99| 15/.99| NR| NR| NR| NR
3/8″| 7/8″| 108| 85| 90| 82| 25/1.00| 50/1.00| 75/1.00| 95/.99| 89/.99| 84/.99| 78/.98| 72/.98| 67/.98| 61/.97
1/2″| 7/8″| 54| 43| 45| 41| 25/1.00| 50/1.00| 75/1.00| 100/.99| 100/.99| 100/.99| 100/.98| 100/.98| 100/.98| 100/.97
3.5 Ton| 3/8″| 3/4″| 150| 123| 102| 75| 25/.99| 50/.98| 75/.97| 88/.96| 80/.95| 72/.94| 65/.92| 57/.91| 49/.90| NR
1/2″| 3/4″| 75| 62| 51| 38| 25/.99| 50/.98| 75/.97| 100/.96| 100/.95| 100/.94| 100/.92| 100/.91| 100/.90| NR
3/8″| 7/8″| 150| 123| 102| 75| 25/1.00| 50/1.00| 75/.99| 88/.99| 80/.99| 72/.98| 65/.97| 57/.97| 49/.96| 42/.96
1/2″| 7/8″| 75| 62| 51| 38| 25/1.00| 50/1.00| 75/.99| 100/.99| 100/.99| 100/.98| 100/.97| 100/.97| 100/.96| 100/.96
Notes**

  1. Do not exceed 200 ft linear line length.
  2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
  3. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

13-16 SEER Single-Stage Air-Conditioners

Unit Size| Allowable Liquid Line Size| Allowable

Suction Line Size

| Apply Long Line Guidelines if Linear Line Length

Exceeds Those Shown Below (Feet)

| Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150| 151-175| 176-200| 201-225| 226-250
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
4 Ton| 3/8″| 3/4″| 148| 110| N/A| 35| 25/.99| 50/.98| 70/.96| 77/.95| 67/.93| 57/.92| 46/.91| NR| NR| NR
1/2″| 3/4″| 74| 55| N/A| 18| 25/.99| 50/.98| 75/.96| 100/.95| 100/.93| 100/.92| 100/.91| NR| NR| NR
3/8″| 7/8″| 148| 110| N/A| 35| 25/1.00| 50/.99| 75/.99| 77/.98| 67/.97| 57/.97| 46/.96| 36/.96| 26/.95| 15/.95
1/2″| 7/8″| 74| 55| N/A| 18| 25/1.00| 50/.99| 75/.99| 100/.98| 100/.97| 100/.97| 100/.96| 100/.96| 99/.95| 97/.95
5 Ton| 3/8″| 3/4″| 78| 55| N/A| 0| 25/.99| 50/.97| 75/.94| 61/.92| 46/.90| NR| NR| NR| NR| NR
1/2″| 3/4″| 39| 28| N/A| 0| 25/.99| 50/.97| 75/.94| 100/.92| 100/.90| NR| NR| NR| NR| NR
3/8″| 7/8″| 78| 55| N/A| 0| 25/1.00| 50/.99| 75/.98| 61/.97| 46/.96| 32/.95| 18/.94| NR| NR| NR
1/2″| 7/8″| 93| 28| N/A| 0| 25/1.00| 50/.99| 75/.98| 100/.97| 100/.96| 100/.95| 18/.94| NR| NR| NR
3/8″| 1-1/8″| 78| 55| N/A| 0| 25/1.01| 50/1.01| 75/1.00| 61/1.00| 46/1.00| 32/.99| 18/.99| NR| NR| NR
1/2″| 1-1/8″| 39| 28| N/A| 0| 25/1.01| 50/1.01| 75/1.00| 100/1.00| 100/1.00| 100/.99| 97/.99| 95/.99| 92/.99| 89/.98
Notes**

1. Do not exceed 200 ft linear line length.

  1. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
  2. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  3. Always use the smallest liquid line allowable to minimize refrigerant charge.
  4. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  5. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Refrigerant Line Size Information

13-16 SEER Single-Stage Air-Conditioners

Unit Size| Allowable Liquid

Line Size mm [in.]

| Allowable Suction Line Size mm [in.]| Apply Long Line Guidelines if Linear Line Length

Exceeds Those Shown Below (Feet)

| Equivalent Length (Feet)
< 8| 8-15| 16-23| 24-30| 31-38| 39-46| 47-53| 54-61| 62-69| 70-76
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier**
5.3 kW [1.5

ton] **See Note 3

| 6.35[1/4]| 9.53[5/8]| N/A| N/A| N/A| N/A| 8/1.0| 15/.99| 19/.98| 13/.98| 7/.97| 2/.97| NR| NR| NR| NR
7.94[5/16]| 15.88[5/8]| N/A| 68| 60| 57| 8/1.0| 15/.99| 23/.98| 30/.98| 28/.97| 27/.97| 25/.96| 24/.96| 22/.95| 21/.94
9.53[3/8]| 15.88[5/8]| 54| 45| 40| 38| 8/1.0| 15/.99| 23/.98| 30/.98| 30/.97| 30/.97| 30/.96| 30/.96| 30/.95| 30/.94
6.35[1/4]| 19.05[3/4]| N/A| N/A| N/A| N/A| 8/1.0| 15/.99| 19/.98| 13/.98| 7/.97| 2/.97| NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]
| N/A| 68| 60| 57| 8/1.0| 15/.99| 23/.98| 30/.98| 28/.97| 27/.97| 25/.99| 24/.98| 22/.98| 21/.98
9.53[3/8]| 19.05[3/4]**| 54| 45| 40| 38| 8/1.0| 15/.99| 23/.98| 30/.98| 30/.97| 30/.97| 30/.99| 30/.98| 30/.98| 30/.98
7.0 kW [2 Ton]| 6.35[1/4]| 15.88[5/8]| N/A| N/A| N/A| N/A| 8/.99| 15/.98| 6/.97| NR| NR| NR| NR| NR| NR| NR
7.94[5/16]| 15.88[5/8]| 74| 65| 59| 53| 8/.99| 15/.98| 23/.97| 27/.96| 23/.95| 21/.94| 19/.93| 16/.92| 14/.91| 11/.90
9.53[3/8]| 15.88[[5/8]| 49| 43| 39| 36| 8/.99| 15/.98| 23/.97| 30/.96| 30/.95| 30/.94| 30/.93| 29/.92| 28/.91| 27/.90
6.35[1/4]| 19.05[3/8]| N/A| N/A| N/A| N/A| 8/1.00| 15/1.00| 6/.99| NR| NR| NR| NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]| 74| 65| 59| 53| 8/1.00| 15/1.00| 23/.99| 27/.99| 23/.98| 21/.98| 19/.98| 16/.97| 14/.97| 11/.96
9.53[3/8]| 19.05[3/4]| 49| 43| 39| 36| 8/1.00| 151/1.00| 23/.99| 30/.99| 30/.98| 30/.98| 30/.98| 29/.97| 18/.97| 27/.96
8.6 kW [2.5

Ton]

| 7.94[5/16]| 15.88[5/8]| N/A| N/A| 40| 34| 8/.99| 15/.98| 23/.96| 21/.94| 18/.93| 15/.91| 11/.90| NR| NR| NR
9.53[3/8]| 15.88[5/8]| 43| 36| 27| 22| 8/.99| 15/.98| 23/.96| 30/.94| 30/.93| 29/.91| 27/.90| NR| NR| NR
7.94[5/16]| 19.05[3/4]| 65| 53| 40| 334| 8/1.00| 15/.99| 23/.99| 21/.98| 18/.98| 15/.97| 11/.96| 8/.96| 4/.95| NR
9.53[3/8]| 19.05[3/4]| 43| 36| 27| 22| 8/1.00| 15/.99| 23/.99| 30/.98| 30/.98| 29/.97| 27/.96| 26/.96| 25/.95| 24/.95
10.6 kW [3 Ton]| 7.94[5/16]| 15.88[5/8]| N/A| N/A| N/A| N/A| 8/.99| 15/.97| 20/.94| 15/.92| 10/.90| NR| NR| NR| NR| NR
9.53[3/8]| 15.88[5/8]| 33| 26| 27| 25| 8/.99| 15/.97| 23/.94| 29/.92| 27/.90| NR| NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]| N/A| 39| 41| 37| 8/1.0| 15/.99| 20/.98| 15/.98| 10/.97| 5/.96| NR| NR| NR| NR
9.53[3/8]| 19.05[3/4]| 33| 26| 27| 25| 8/1.00| 15/.99| 23/.99| 29/.98| 27/.97| 26/.96| 24/.95| 22/.92| 20/.93| 19/.93
12.70[1/2]| 19.05[3/4]| 17| 13| 14| 12| 8/1.00| 15/.99| 23/.98| 30/.98| 30/.97| 30/.96| 30/.95| 100/.92| 30/.93| 30/.93
7.94[5/16]| 22.23[7/8]| N/A| 39| 41| 37| 8/1.00| 15/1.00| 20/1.00| 15/.99| 10/.99| 5/.99| NR| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 33| 26| 27| 25| 8/1.00| 15/1.00| 23/1.00| 29/.99| 27/.99| 26/.99| 24/.98| 22/.98| 20/.98| 19/.97
12.70[1/2]| 22.23[7/8]| 17| 13| 14| 12| 8/1.00| 15/1.00| 23/1.00| 30/.99| 30/.99| 30/.99| 30/.98| 30/.98| 30/.98| 30/.97
12.3 kW [3.5 Ton]| 9.53[3/8]| 19.05[3/4]| 46| 36| 31| 23| 8/.99| 15/.98| 23/.97| 27/.96| 24/.95| 22/.94| 20/.92| 17/.91| 15/.90| NR
12.70[1/2]| 19.05[3/4]| 23| 19| 15| 11| 8/.99| 15/.98| 23/.97| 30/.96| 30/.95| 30/.94| 30/.92| 30/.91| 30/.90| NR
9.53[3/8]| 22.23[7/8]| 46| 38| 31| 23| 8/1.00| 15/1.00| 23/.99| 27/.99| 24/.99| 22/.98| 20/.97| 17/.97| 15/.96| 13/.96
12.70[1/2]| 22.23[7/8]| 23| 19| 15| 11| 8/1.00| 15/1.00| 23/.99| 30/.99| 30/.99| 30/.98| 30/.97| 30/.97| 30/.96| 30/.96
Notes

  1. Do not exceed 200 ft linear line length.
  2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
  3. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

13-16 SEER Single-Stage Air-Conditioners

Unit Size| Allowable Liquid Line Size| Allowable Suction Line Size| Apply Long Line Guidelines if Linear Line Length

Exceeds Those Shown Below (Feet)

| Equivalent Length (Feet)
< 8| 8-15| 16-23| 24-30| 31-38| 39-46| 47-53| 54-61| 62-69| 70-76
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
4 Ton| 9.53[3/8]| 19.05[[3/4]| 45| 34| N/A| 11| 8/.99| 15/.98| 23/.96| 24/.95| 20/.93| 17/.92| 14/.91| NR| NR| NR
12.7[1/2]| 19.05[3/4]| 23| 17| N/A| 5| 8/.99| 15/.98| 23/.96| 30/.95| 30/.93| 30/.92| 30/.91| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 45| 34| N/A| 11| 8/1.00| 15/.99| 23/.99| 24/.98| 20/.97| 17/.97| 14/.96| 11/.96| 8/.95| 5/.95
12.7[1/2]| 22.23[7/8]| 23| 17| N/A| 5| 8/1.00| 15/.99| 23/.99| 30/.98| 30/.97| 30/.97| 30/.96| 30/.96| 30/.95| 30/.95
5 Ton| 9.53[3/8]| 19.05[3/4]| 24| 17| N/A| 0| 8/.99| 15/.97| 23/.94| 19/.92| 14/.90| NR| NR| NR| NR| NR
12.7[1/2]| 19.05[3/4]| 12| 8| N/A| 0| 8/.99| 15/.97| 23/.94| 30/.92| 30/.90| NR| NR| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 24| 17| N/A| 0| 8/1.00| 15/.99| 23/.98| 19/.97| 14/.96| 10/.95| 5/.94| NR| NR| NR
12.7[1/2]| 22.23[7/8]| 12| 8| N/A| 0| 8/1.00| 15/.99| 23/.98| 30/.97| 30/.96| 30/.95| 30/.94| 29/.94| 28/.93| 2/.92
9.53[3/8]| 28.58[1-1/8]| 24| 17| N/A| 0| 8/1.01| 15/1.01| 23/1.00| 19/1.00| 14/1.00| 10/.99| 5/.99| NR| NR| NR
12.7[1/2]| 28.58[1-1/8]| 12| 8| N/A| 0| 8/1.01| 15/1.01| 23/1.00| 30/1.00| 30/1.00| 30/.99| 30/.99| 29/.99| 28/.99| 27/.98
Notes**

  1. Do not exceed 200 ft linear line length.
  2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
  3. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Performance Data @ AHRI Standard Conditions – Cooling

Designated Test Combinations (DTC)

Outdoor Unit| Indoor Coil| Total Capacity

BTU/H [kW]

| Net Sensible

BTU/H [kW]

| Net Latent BTU/H

[kW]

| SEER| EER| Inddor CFM [L/s]
RP1624AJ| TZHDLVMT2421| 24000 [7]| 19200 [5.6]| 4800 [1.4]| 16| 13| 825 []
RP1636AJ| TZHDLVMT3621| 34200 [9.9]| 27360 [7.9]| 6840 [2]| 16| 13| 1225 []
RP1648AJ| TZHDLVMT4821| 45500 [13.2]| 36400 [10.6]| 9100 [2.6]| 16| 12.5| 1650 []
RP1660AJ| TZHDLVST6024| 57000 [16.5]| 45600 [13.2]| 11400 [3.3]| 16| 12.5| 1725 []

Note: Additional ratings and system match ups can be accessed on MyRheem.com at: https://my.rheem.com/static/private/ahriresidential.html Additional ratings and system match ups and downloadable ratings certificates can be accessed from the AHRI website: www.ahridirectory.org

[ ] Designates Metric Conversions

**GENERAL TERMS OF LIMITED WARRANTY***

Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.

*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.

| Conditional Parts

(Registration Required) __ Ten (10) Years