i-PRO WJ-PU201P PoE Camera Power Unit Instruction Manual

June 14, 2024
i-PRO

i-PRO WJ-PU201P PoE Camera Power Unit Instruction Manual

Product outline

This unit is a PoE camera power unit that enables i-PRO network cameras to operate by supplying power from a network cable. For the latest information on supported cameras, refer to our technical information website <Control number: C0501>.

WARNING:

  • All work related to the installation and earthing of this product should be made by qualified service personnel or system

Caution:

  • The network camera is only intended for a connection to an ethernet or PoE network without routing to the outside
  • The socket-outlet shall be easily
  • Only use the included AC
  • Do not use the included AC cord with other
  • Shielded (STP) LAN cables must be used with this unit to ensure compliance with EMC
  • Before attempting to connect or operate this product, please read these instructions

Notice:

  • This product is not suitable for use in locations where children are likely to be
  • This product is a professional
  • This product must be connected to a grounded

—Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord.
—Laite on liitettävä suojakoskettimilla varustettuun pistorasiaa
—Apparatet må tilkoples jordet stikkontakt.
—Apparaten skall anslutas till jordat uttag.
: Direct current symbol
: Alternation current symbol
: For indoor use only

Precautions

Do not insert any foreign

Fire or electrical shock may be caused if water or any foreign objects, such as metal objects, enter inside the unit.
Turn the power off immediately and contact qualified service personnel for service.

Do not use this product in an inflammable atmosphere.

Failure to observe this may cause an explosion resulting in injury.

Do not strike or give a strong shock to this product.

Failure to observe this may cause injury or fire.

Do not damage the power cord.

Do not damage, fabricate, twist, stretch, bundle, or forcibly bend the power cord. Do not place heavy objects on it, and keep it away from heat sources.

Use of a damaged power cord may cause electric shock, short circuit, or fire. Consult the dealer for repair.

Do not forcibly pull on the cable.

Doing so may result in a fire or electric shock.
Tokyo, Japan https://www.i-pro.com/1010 Cambourne Business Park, Cambridgeshire CB23 6DPavs0322-1062

Do not place containers with liquids such as water on the product.

Liquids such as water getting inside may cause fire or electric shock. Disconnect the power plug immediately and contact your dealer.

Never touch the power plug with wet hands.

This may result in electric shock.
Do not attempt to disassemble or modify this product.
Failure to observe this may cause fire or electric shock. Consult the dealer for the repair or inspections.

Do not install or clean the camera, or touch this product, the power cord

or the connected cables during thunder storms.

Failure to observe this may cause electric shock.

Refer installation work to the dealer.

Installation work requires technique and experience. Failure to observe this may cause fire, electric shock, injury, or damage to the product. Be sure to consult the dealer.

 Stop the operation immediately when something is wrong with this product.

Using it as is while there is smoke or a smell may cause damage. Disconnect the power plug immediately and contact your dealer.

Turn the power off when do wirning of this product.

Failure to observe this may cause electric shock. In addition, short circuit or wrong wiring may cause fire.

Correctly perform all wiring.

Short circuits in the wiring or incorrect wiring may cause fire or electric shock.

 Turn the power off when cleaning this product.

Failure to observe this may cause electrical shock.

 Completely insert the power plug into the power outlet.

Failure to do so may cause electric shock and/or excessive heat resulting in a fire. Do not use damaged power plugs or power outlets.

 Always hold the plug when unplugging the power cord.

Otherwise, the cord may be damaged and result in a fire or electric shock.

Regularly remove any dust, etc. from the power plug.

Accumulated dust may cause an insulation defect from moisture, etc., resulting in a fire. Disconnect the power plug, then wiping with a dry cloth.

 If you do not use the unit for a long period of time, unplug the power

cord from the receptacle.

Otherwise, it may result in a fire or electric shock

About notations

The following notations are used when describing the functions limited for specified models. The functions without the notations are supported by all models.
The functions with this notation are available when using the model WJ-PU201P, WJ-PU201/G. The functions with this notation are available when using the model WJ-PU201F/G.
“<Control No.: C****>” used in these documents should be used to search for information on our technical information website (https://i-pro.com/global/en/surveillance/training- support/support/technical- information) and will guide you to the right information.

Disposal of Old Equipment

Only for European Union and countries with recycling systems

This symbol on the products, packaging, and/or accompanying documents means that used electrical and electronic products must not be mixed with general household waste.
For proper treatment, recovery and recycling of old products, please take them to applicable collection points in accordance with your national legislation.
By disposing of them correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment. For more information about collection and recycling, please contact your local municipality.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation

For U.S.A.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving
  • Increase the separation between the equipment and
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is
  • Consult the dealer or an experienced radio/TV technician for

FCC CAUTION

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Supplier’s Declaration of conformity
Trade name : i-PRO                   Responsible Party : i-PRO Americas Inc.
Model No. : WJ-PU201/        8550 Fallbrook Drive, Suite 200 Houston,Texas 77064 WJ-PU201F           Support Contact : 1-800-513-5417

For U.K.

FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.

This appliance is supplied with a moulded three pin mains plug for your safety and convenience. A 5 amp fuse is fitted in this plug. Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 5 amp and that it is approved by ASTA or BSI to BS1362.
Check for the ASTA mark    or the BSI mark     on the body of the fuse. If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced. If you lose the fuse cover the plug must not be used until a replacement cover is obtained. A replacement fuse cover can be purchased from our dealer.

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY. THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.

How to replace the fuse

The location of the differs according to the type of AC mains plug (figures A and B). Confirm the AC mains plug fitted and follow the instructions below. Illustrations may differ from actual AC mains plug. Open the fuse cover with a screwdriver and replace the fuse and close or attach the fuse cover

Specifications

Power source: 100 to 240 V AC (50 Hz/60 Hz)
Input power consumption: PU201 2.0 A (RMS) max for 90 V AC, 1.2 A (RMS)

max for 240 V AC

PU201F 2.0 A (RMS) max for 90 V AC, 1.0 A (RMS) max for 240 V AC

Output power consumption:| 56 V DC: Approx. 1.07 A / 60 W

(Combined output on data pairs and spare pairs.)

Operating environment

Ambient operating temperature:

Ambient operating humidity:

|

60 W output: –10 °C to +40 °C {14 °F to 104 °F}

30 W output: –10 °C to +50 °C {14 °F to 122 °F}

10 % to 90 % (no condensation)

Strage environment

Storage temperature:

Storage humidity:

|

–20 °C to +65 °C {–4 °F to +149 °F}

10 % to 90 % (no condensation)

Network:| 10BASE-T/100BASE-TX/1000BASE-T, RJ45 connector (×2)

Compliant with IEEE802.3bt/at/af Standard

PU201F Standard SFP module port (LC type) (×1)

AC Input:| IEC320 (C14)
Dimension:

(excluding power cord/cables)

| PU201 65 mm (W) × 36 mm (H) × 163 mm (D)

{2-9/16 inches (W) × 1-13/32 inches (H) × 6-13/32 inches (D)}

PU201F 80 mm (W) × 50 mm (H) × 184 mm (D)

{3-5/32 inches (W) × 1-31/32 inches (H) × 7-1/4 inches (D)}

(excluding cord and plag)

Mass:| PU201 Approx. 300 g {0.66 lbs}

PU201F Approx. 465 g {1.03 lbs}

Finish:| PC/ABS resin, Matte black

Standard accessories

Operating Instructions (this document)………………………………….. 1 pc.
Power cord (A type)…………………………………………………………. 1 pc.
Power cord (C type) (BF type)……………………………………………….. each 1 pc.<WJ-PU201/G><WJ- PU201F/G>

Precautions for installation

Parts and functions

<WJ-PU201/G>

LED Indicators

  • Power failure Lights off
  • POE power ready but no connection Lights amber short/slow Blinking
  • POE output power good Lights green
  • POE detection failure Lights Amber/Green alternate blinking
  • POE output over power or short Lights amber long/fast blinking
  • Invalid load condition Blinks green

LED Indicators

  • Power failure Lights off
  • AC Power Good Lights green

  • POE power ready but no connection Lights amber short/slow Blinking
  • POE output power good Lights green
  • Unit is in Over Load Condition or Unit has detected an Invalid Load Lights red

Making connections

PU201

**IMPORTANT:**

  • For the Ethernet cable, use a shielded network cable (STP) CAT5e or
  • Make sure that the cable length from the RJ45 network terminal (OUT/DATA PWR OUT) to the camera is 100 m or less.
  • When using a splitter, connect it at a point close to the camera, not the PoE Camera Power Unit
  • Use this unit on a flat table without securing it in place with Do not secure it in place on a ceiling or wall with screws.

Troubleshooting

Symptom Cause/solution Reference pages
The PoE Camera Power Unit does not turn on. LED indicator PU201 and POWER

indicator

PU201F do not light or blink.

• Make sure that the power cord is properly connected to this unit.

• Make sure that the voltage of the outlet is 100 to

240 V AC.

| Parts and functions
The camera connected to the PoE Camera Power Unit does not turn on.| LED indicator PU201 and POWER indicator

PU201F do not light green.

• Make sure that the input Ethernet cable is connected to the RJ45 network terminal (IN/DATA IN), and

the camera side is connected to the RJ45 network terminal (OUT/DATA PWR OUT).

• Make sure that the unit and the camera are connected with a straight network cable of STP CAT5 or higher.

• Make sure that the twisted pair cable or RJ45 connector is not short- circuited.

• If you are using a power splitter, make sure it is working properly.

| Making connections
The camera connected to the PoE Camera Power Unit turns on, but a data link is not established.| LED indicator PU201 and POWER indicator

PU201F blink Amber/Green.

• Make sure that the unit and the camera are connected with a straight network cable of STP CAT5 or higher.

• If you are using an RJ45 Ethernet cable, make sure the length of the cable from the HUB to the camera is less than 100 m.

• If you are using a power splitter, make sure it is working properly.

|

Image data cannot be transmitted by the optical fiber cord.

PU201F

| • Make sure that the SFP module is installed correctly in this unit.

• Make sure that the connector of the optical fiber cord is appropriately connected to the SFP module.

• Check if the optical fiber cord appropriately operates by replacing the optical fiber cord with new one.

|

Read More About This Manual & Download PDF: