Rheem RTX3-04 Series Comfort MR Water Heater Instruction Manual

May 15, 2024
Rheem

Rheem RTX3-04 Series Comfort MR Water Heater

Rheem-RTX3-04-Series-Comfort-MR-Water-Heater

Specifications

Model| Resistances| Voltage| Max kW| kW per Resistance| Amperage| Breakers| Wire Gauge
---|---|---|---|---|---|---|---
RTX3-04| 1| 120 V| 3.2 kW| 3.2 kW| 27 AMPS| 1×30 AMP| 1×10 AWG
RTX3-08| 1| 240 V| 7 kW| 7 kW| 29 AMPS| 1×40 AMP| 1×8 AWG
RTX3-13| 2| 240 V| 13 kW| 6.5 kW| 54 AMPS| 1×60 AMP| 1×6 AWG
RTX3-18| 2| 240 V| 17 kW| 8.5 kW| 71 AMPS| 2×40 AMP| 1×6 AWG
RTX3-27| 3| 240 V| 27 kW| 9 kW| 112 AMPS| 3×40 AMP| 1×8 AWG

Product Usage Instructions

Installation:

  1. Ensure there is a clearance of 30.5 cm above and below the water heater and 15.25 cm in front and on the sides.
  2. Leave at least 30 cm (12 inches) of space above and below the unit for servicing. Set the water temperature knob to your desired temperature.
  3. Use a flow restrictor for proper operation.

Water Connections:

  • To eliminate air from the system: – Model RTX3-18: Connect four gauge 8 AWG STW cables to inputs L1 and L2 for each 40A breaker of the heater, and one gauge 8 AWG STW cable for ground.
  • Model RTX3-27: Connect six gauge 8 AWG STW cables to inputs L1 and L2 for each 40A breaker of the heater, and one gauge 8 AWG STW cable for ground.
  • All models: – Follow the wiring instructions provided by a qualified professional to avoid risks.

Maintenance:
Regular maintenance and routine preventive maintenance are essential to ensure proper functionality and safety. Always consult a qualified technician for maintenance tasks.

Frequently Asked Questions (FAQ)

Issue:

No hot water or insufficient water.

Possible Causes:

  • Hot water taps are open or leaking.
  • Incorrect wiring.