PANDUIT FS200 Front Access Splice Cassette Instruction Manual
- June 13, 2024
- PANDUIT
Table of Contents
FlexCore™ Fusion Splice Cassette
Cable to LC Adapter
©Panduit Corp. 2022
INSTALLATION INSTRUCTIONS FS200
TABLE 1: CASSETTE SPECIFIC COMPONENTS
PRODUCT FAMILY
| CASSETTE PART NUMBER| CASSETTE DESCRIPTION
24 FIBER LC SPLICE CASSETTE PRELOADED WITH DISCRETE PIGTAILS| FDS9N-24-10P|
24F FRONT ACCESS SPLICE CASSETTE LC OS2 UPC DISCRETE PIGTAILS, STD IL
FDS9N-24-LAP
| 24F FRONT ACCESS SPLICE CASSETTE LC OS2 APC DISCRETE PIGTAILS, STD IL
FDSZA-24-10P|
24F FRONT ACCESS SPLICE CASSETTE LC OM4 DISCRETE PIGTAILS, ULTRA IL
FDSSA-24-10P
| 24F FRONT ACCESS SPLICE CASSETTE LC OM4+ DISCRETE PIGTAILS, ULTRA IL
FDSWA-24-10P|
24F FRONT ACCESS SPLICE CASSETTE LC OM5 DISCRETE PIGTAILS, ULTRA IL
FDSZO-24-10P
| 24F FRONT ACCESS SPLICE CASSETTE LC OM4 DISCRETE PIGTAILS, OPT IL
24 FIBER LC SPLICE CASSETTE PRELOADED WITH RIBBON PIGTAILS| FDSZA-24-10R|
24F FRONT ACCESS SPLICE CASSETTE LC O4 RIBBON PIGTAILS, ULTRA IL
FDSZO-24-10R
| 24F FRONT ACCESS SPLICE CASSETTE LC OM4 RIBBON PIGTAILS, OPT IL
FDS9N-24-10R|
24F FRONT ACCESS SPLICE CASSETTE LC 0S2 UPC RIBBON PIGTAILS, STD IL
FDS9N-24-LAR
|
24F FRONT ACCESS SPLICE CASSETTE LC OS2 APC RIBBON PIGTAILS, STD IL
WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. MAINTAIN DUST CAPS ON UNMATED CONNECTORS.
Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Consult the manufacturer’s cable specification sheet for specific cable to use.
Figure 1
- Cover
- Cover Removal Latch
- Base
To remove the cover:
- While pressing down on the Cover Removal Latch, slide the cover backwards until it stops
- Then lift the cover upwards
Internal Features
Figure 2
- Routing Tabs (8) Per Side
- Ribbon Fiber Splice Sleeve Holders (2) Per Side
- Discrete Fiber Splice Sleeve Holders (12) Per Side Double Stacked
- Spiral Wrap (1) Per Side
- Pre-Loaded Pig Tails (12) Per Side
- LC Adapters (6) Per Side
- Screws Aramid Yarn Strain Relief (2) Per Side
Fiber Wire Input Options
Option #1. Installing cable directly onto the cassette
1. Strip incoming outer cable field jacket 39 inches [990mm], secure with Pan-Ty™ cable ties and aramid yarn with screw (optional).
Figure 3
- Screws Aramid Yarn Strain Relief
2. Expose all fiber ends for splicing. Slide a splice sleeve onto either the pigtail or field fiber. Splice all fibers and heat splice sleeve(s). Refer to splicer manufacturer best practice instructions.
Option #2. Installing protection (furcation) tube(s) onto the cassette
1. Attach the furcation tube(s) onto the cassette utilizing Pan-Ty cable ties, leaving 39 inches [990mm] of exposed fiber in preparation for splice
Figure 4
- Strength Members Locked Beneath Screw
- Pan-Ty Cable Tie (2) Per Side
- Ribbon Furcation Tube(s)
2. Expose all fiber ends for splicing. Slide a splice sleeve onto either the pigtail or field fiber. Splice all fibers and heat splice sleeve(s). Refer to splicer manufacturer best practice instructions.
Option #3. Installing protection tube(s) onto the cassette
1. Attach the protection tube(s) onto the cassette utilizing Pan-Ty cable ties, leaving 39 inches [990mm] of exposed fiber in preparation for splice
Figure 5
-
Pan-Ty Cable Tie (2) Per Side
-
Wrap electrical tape 5-7 times around where Pan-Ty Cable Ties are installed.
Cinch cable ties around electrical tape. -
5.0mm Protection Tube
2. Expose all fiber ends for splicing. Slide a splice sleeve onto either the pigtail or field fiber. Splice all fibers and heat splice sleeve(s). Refer to splicer manufacturer best practice instructions.
NOTE:
Be mindful of the following during installation:
- Maximum Input / Output cable diameter of 0.276 inches [7mm] X 4 positions
- Maintain a minimum fiber/cable bend radii of 1 inch [25.4mm]
- Avoid over-tightening the cable ties, crushing the fiber cable
- (1) Pan-Ty Cable tie per side if both entry slots are being used
- Up to (2) splice sleeves can be stacked under each splice sleeve holder
- Furcation kits FOBKFYM1 and FOBKFAM1 can be purchased separately
- Reference Appendix “C” for available Protection Tube Kits
Discrete Splice. Cable Input to LC Adapter Output – Left Hand Input Wire Routing
Figure 6
Discrete Splice. Cable Input to LC Adapter Output – Right Hand Input Wire Routing
Figure 7
Ribbon Splice. Cable Input to LC Adapter Output – Left Hand Input Wire Routing
Figure 8
Ribbon Splice. Cable Input to LC Adapter Output – Right Hand Input Wire Routing
Figure 9
Figure 10
- Cover
- Base
To install the cover:
- Place the cover on the base, aligning the side cover latches
- Slide the cover forward until the cover latch engages with the base
Additional splice protectors available from Panduit:
FOSP40-C: Single (Discrete) Fiber Splice Protection (QTY: 100 pcs)
FOWPR40-L: Ribbon Fiber Splice Protectors (QTY: 50 pcs)
APPENDIX “A” – FlexCore™ Cassette / ODF System Installation Instruction
Matrix
Specification Number
|
Description
---|---
FS187
| Fiber Breakout Kit, Flat Ribbon Furcation Tube (P/N FOBKF**(Y/A)M1) Installation Instructions
FS190
| FlexCore™ Optical Distribution Frame Installation Instructions
FS191
| FlexCore™ 150mm Vertical Cable Manager Installation Instructions
FS192
| FlexCore™ 300mm Vertical Cable manager
FS193
| FlexCore™ Single Hinge Front Doors Installation Instructions
FS194
| FlexCore™ End Panels Installation Instructions
FS198
| FlexCore™ Spool – Single
FS199
| FlexCore™ Spools – 6 Pack Color Coordinated Kit
FS200
| FlexCore™ Fusion Splice Cassette – Cable to LC Adapter Installation Instructions
FS201
| FlexCore™ Fusion Splice Cassette – Cable to Cable Installation Instructions
FS202
| FlexCore™ Cassettes (LC/MPO, LC/Tether)
FS203
| FlexCore™ 4RU Universal Enclosure installation Instructions
FS204
| FlexCore™ Front Access Optical Distribution Frame Patchcord Routing Guide
FS205
| FlexCore™ Frame Rear panel
FS206
| FlexCore™ Front Access Ingress / Egress Cabling Guide
For copies of FlexCore™ Optical Distribution Frame System installation instructions, please visit www.panduit.com and search for the specific Specification Number
For Technical Support:www.panduit.com/resources/install_maintain.asp
APPENDIX “B” – Cable Ingress / Egress Options
Cable To LC Adapter Cassettes
Ingress cable enters on one side
(Left or Right)
Ingress cable enters on both sides
(Left and Right)
APPENDIX “C” – Protection Tubing Options
QuickNet FIBER BREAKOUT / FURCATION KITS
Part Number| Jacket Color| Fiber Count| # Of Tubes|
Cable OD (Max)
SINGLEMODE
FOBKF24YM1
| Yellow| 24| 2| 0.38″ [9.6mm]
FOBKF48YM1| Yellow| 48| 4|
0.45″ [11.4mm]
FOBKF72YM1
| Yellow| 72| 6| 0.45″ [11.4mm]
FOBKF96YM1| Yellow| 96| 8|
0.45″ [11.4mm]
FOBKF144YM1
| Yellow| 144| 12| 0.625″ [15.9mm]
FOBKF288YM1| Yellow| 288| 24|
0.875″ [22.2mm]
FOBKF432YM1
| Yellow| 432| 36| 0.90″ [22.8mm]
FOBKF576YM1| Yellow| 576| 48|
1.07″ [27.2mm]
FOBKF864YM1
| Yellow| 864| 92|
1.07″ [27.2mm]
MULTIMODE
FOBKF24AM1
| Aqua| 24| 2| 0.38″ [9.6mm]
FOBKF48AM1| Aqua| 48| 4|
0.45″ [11.4mm]
FOBKF72AM1
| Aqua| 72| 6| 0.45″ [11.4mm]
FOBKF96AM1| Aqua| 96| 8|
0.45″ [11.4mm]
FOBKF144AM1
| Aqua| 144| 12|
0.625″ [15.9mm]
PROTECTIVE TUBES
Part Number| Description|
# Of Tubes
FDFMX5KITBL
| Breakout Kit with 2ft Protective Tube| 12
FM5PPBLF2.0-12| 2ft Protective Tube|
12
FM5PPBLF4.0-12
| 4ft Protective Tube| 12
FM5PPBLF8.0-12| 8ft Protective Tube|
12
For Instructions in Local Languages and Technical Support:
http://www.panduit.com/resources/install_maintain.asp
E-mail:
techsupport@panduit.com
Phone:
866-405-6654
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>