WHAT YOU WILL NEED :
3/8” open/box wrench or adjustable wrench
2 Phillips screwdriver
Slip joint pliers
Side cutting pliers
NOTE : This pump can be installed in a gourmet cube ice machine or a nugget ice machine.
KIT CONTENTS
- Pump and motor with check valve
- Switch mounting bracket assembled to switch assembly
- Wire harness
- Discharge tubing (clear)
- Drain tube (white preformed)
- Stainless steel shield (for use in cube models only)
- Snap fit clamp
- Hose clamp
- 2 Screws with lock washers
- 2 Nuts
- 2 Washers
INSTALLING PUMP KIT
DISCONNECT ELECTRICAL POWER
Electrical Shock Hazard
Death or serious injury can result from failure to follow these instructions.
- Service by a qualified service technician only.
- Disconnect power before servicing this product.
- Reconnect all grounding devices after service.
- Replace all parts and panels before operating.
REMOVE BACK PANEL
A. Remove all ice if applicable.
B. Drain reservoir by removing reservoir drain cap. Replace cap when water has
drained.
C. Remove the screws from the back panel (19 for gourmet cube models; 15 for
nugget models).
D. Remove the side service panel. Pull out on the left side (1) and back (2)
to remove.
REMOVE FRONT PANELS
A. Open the ice machine door all the way.
B. Remove the Service Panel by first removing the Circular Screw Cover and
then the screw.
C. Remove the Kickplate by removing the 2 screws securing it to the base.
REMOVE EXISTING DRAIN TUBE
Remove the existing drain tube. The drain tube is the white tube with a white
snap fit clamp on it in the upper left hand corner of the side service panel
access area. Save the snap fit clamp. It will be used to install the new drain
tube.
INSTALL THE PUMP KIT
A. Uncoil the 10-foot long discharge tubing (clear). Push one end completely
onto the barbed discharge elbow of the pump and securely fasten it with the
small metal hose clamp. Use pliers to open the hose clamp.
B. Route the other end of the discharge tubing through the routing panel in
the back of the unit. Put the end of the discharge tube into a drain.
C. Place the pump over the bolts located on the base of the ice machine and
secure with the two nuts and washers provided in the kit.
D. Route the straight portion of drain tube through the hole in switch
assembly bracket.
E. Connect drain tube to pump inlet and secure with the white snap fit clamp
from the kit.
F. Connect the pressure switch hose to the drain tube.
G. Mount the switch assembly bracket to the base using two provided sheet
metal screws and lock washers.
H. Trace the black and white power cord from the switch assembly to the black
and white power cord coming from the unit near the compressor. Make sure that
the wires lay on the left side of the pump if you are facing the unit from
behind. Unplug the current black and white wire’s connection. Plug the black
and white wire’s connector from the unit into the black and white connector
from the switch assembly.
I. Repeat with the red and white connections. It is not necessary to replace
the wire tie that is removed to disconnect the connector. Connect the 3-pin
connector from the switch assembly bracket to the 3-pin connector on the pump.
J. Refer to the unit’s wiring diagram and re-check all electrical connections
for proper placement.
K. Connect drain tube to bin drain, and secure with the snap fit clamp
reserved from removing the old drain tube.
FLUSH OUT THE DRAIN TUBE
A. Restore power to the unit.
B. With the unit still OFF, pour several quarts of water into the bin. The
drain pump should turn on and pump the water out of the bin, cycling on and
off several times during the process. Pump cycling is normal since the pump-
out rate of the drain pump is greater than the rate of drain through the bin.
C. While the pump is discharging water, THOROUGHLY CHECK THE ENTIRE DRAIN
SYSTEM FOR LEAKS.
GOURMET CUBE ICE MACHINE ONLY
Attach stainless steel shield to side of condenser shroud using provided
screws.
FINALIZE INSTALLATION
A. Re-install all panels and covers.
B. Re-install unit into built-in or free-standing location. ENSURE THAT NO
KINKS OCCUR IN WATER INLET OR DRAIN TUBING. Double-check for leaks!
C. Restore potable water supply and restart the unit. Check unit to ensure
proper operation and to allow a final check for leaks of any kind.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>