GE APPLIANCES UPK3 Drain Pump Kit Installation Guide

June 13, 2024
GE Appliances

GE APPLIANCES UPK3 Drain Pump Kit

GE APPLIANCES UPK3 Drain Pump Kit

BEFORE YOU BEGIN

Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local inspector’s use.
  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical skills.
  • Proper installation is the responsibility of installer.
  • Product failure due to improper installation is not covered under the Warranty.

WHAT YOU WILL NEED :
3/8” open/box wrench or adjustable wrench

2 Phillips screwdriver

Slip joint pliers
Side cutting pliers

NOTE : This pump can be installed in a gourmet cube ice machine or a nugget ice machine.

KIT CONTENTS

  1. Pump and motor with check valve
  2. Switch mounting bracket assembled to switch assembly
  3. Wire harness
  4. Discharge tubing (clear)
  5. Drain tube (white preformed)
  6. Stainless steel shield (for use in cube models only)
  7. Snap fit clamp
  8. Hose clamp
  9. 2 Screws with lock washers
  10. 2 Nuts
  11. 2 Washers
    Kit Content

INSTALLING PUMP KIT

DISCONNECT ELECTRICAL POWER

Symbol Electrical Shock Hazard
Death or serious injury can result from failure to follow these instructions.

  • Service by a qualified service technician only.
  • Disconnect power before servicing this product.
  • Reconnect all grounding devices after service.
  • Replace all parts and panels before operating.

REMOVE BACK PANEL

A. Remove all ice if applicable.
B. Drain reservoir by removing reservoir drain cap. Replace cap when water has drained.
Installation Instructions

C. Remove the screws from the back panel (19 for gourmet cube models; 15 for nugget models).
Installation Instructions

D. Remove the side service panel. Pull out on the left side (1) and back (2) to remove.
Installation Instructions

REMOVE FRONT PANELS

A. Open the ice machine door all the way.
B. Remove the Service Panel by first removing the Circular Screw Cover and then the screw.
C. Remove the Kickplate by removing the 2 screws securing it to the base.
Installation Instructions

REMOVE EXISTING DRAIN TUBE

Remove the existing drain tube. The drain tube is the white tube with a white snap fit clamp on it in the upper left hand corner of the side service panel access area. Save the snap fit clamp. It will be used to install the new drain tube.
Installation Instructions

INSTALL THE PUMP KIT

A. Uncoil the 10-foot long discharge tubing (clear). Push one end completely onto the barbed discharge elbow of the pump and securely fasten it with the small metal hose clamp. Use pliers to open the hose clamp.
Installation Instructions

B. Route the other end of the discharge tubing through the routing panel in the back of the unit. Put the end of the discharge tube into a drain.
Installation Instructions

C. Place the pump over the bolts located on the base of the ice machine and secure with the two nuts and washers provided in the kit.
Installation Instructions

D. Route the straight portion of drain tube through the hole in switch assembly bracket.
Installation Instructions

E. Connect drain tube to pump inlet and secure with the white snap fit clamp from the kit.
F. Connect the pressure switch hose to the drain tube.
Installation Instructions

G. Mount the switch assembly bracket to the base using two provided sheet metal screws and lock washers.
Installation Instructions

H. Trace the black and white power cord from the switch assembly to the black and white power cord coming from the unit near the compressor. Make sure that the wires lay on the left side of the pump if you are facing the unit from behind. Unplug the current black and white wire’s connection. Plug the black and white wire’s connector from the unit into the black and white connector from the switch assembly.
I. Repeat with the red and white connections. It is not necessary to replace the wire tie that is removed to disconnect the connector. Connect the 3-pin connector from the switch assembly bracket to the 3-pin connector on the pump.
J. Refer to the unit’s wiring diagram and re-check all electrical connections for proper placement.
K. Connect drain tube to bin drain, and secure with the snap fit clamp reserved from removing the old drain tube.
Installation Instructions

FLUSH OUT THE DRAIN TUBE

A. Restore power to the unit.
B. With the unit still OFF, pour several quarts of water into the bin. The drain pump should turn on and pump the water out of the bin, cycling on and off several times during the process. Pump cycling is normal since the pump- out rate of the drain pump is greater than the rate of drain through the bin.
C. While the pump is discharging water, THOROUGHLY CHECK THE ENTIRE DRAIN SYSTEM FOR LEAKS.

GOURMET CUBE ICE MACHINE ONLY

Attach stainless steel shield to side of condenser shroud using provided screws.
Installation Instructions

FINALIZE INSTALLATION

A. Re-install all panels and covers.
B. Re-install unit into built-in or free-standing location. ENSURE THAT NO KINKS OCCUR IN WATER INLET OR DRAIN TUBING. Double-check for leaks!
C. Restore potable water supply and restart the unit. Check unit to ensure proper operation and to allow a final check for leaks of any kind.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE Appliances User Manuals

Related Manuals