Prestel CSP-4 Network Serial Port Expander User Manual
- June 13, 2024
- Prestel
Table of Contents
Prestel CSP-4 Network Serial Port Expander
Thank you for purchasing this product
For optimum performance and safety, please read these instructions carefully before connecting, operating or adjusting this product. Please keep this manual for future reference.
Surge protection device recommended
This product contains sensitive electrical components that may be damaged by electr-ical spikes, surges, electric shock, lighting strikes, etc. Use of surge protection systems is highly recommended in order to protect and extend the life of your equipment.
Introduction
This Network Serial Port Expander, with 4 extended input and output serial ports, can communicate with the programmable central control system or PC to control multiple devices, and perform protocol conversion between various devices with different communication modes. Built-in various input communication interfaces, the expander can communicate with the programmable central control host or PC through RS-232, RS-422, RS-485 and Network communication interface. The front panel of the expander is designed with LED indicators for power supply, main & extended serial ports sending/receiving data, which can conveniently and quickly indicate the progress of data communication and equipment power failure.
Features
-
Main serial ports support RS-232, RS-422 full duplex, and RS-485 half duplex; extended serial port 1 and extended serial port 2 support RS-232, RS-232+ hardware flow control, RS-422 full duplex, and RS-485 half duplex; extended serial port 3 and extended serial port 4 support RS-232 and RS-232+ hardware flow control
-
Extended serial ports support any baud rate (2400, 4800, 9600, 14400, 19200, 38400, 5600, 57600, 115200) to communicate with devices
-
Extended serial ports support data bits (7, 8 bits), parity bits (odd, even, none), stop bits (1, 2 bits) settings
-
Large buffering space for data transmitting and receiving is reserved for each serial port; data queue is supported
-
Each frame of data can support up to 512 bytes
-
Support data pass-through from an extended serial port to TCP/IP or UDP network
-
Can be used as a protocol converter for serial communication and network communication; 2 network communication modes are provided:
a. TCP acts as a server, and the extender listens for TCP connection requests on the specified TCP port;
b. UDP acts as a server, and the extender listens for UDP connection requests on the specified UDP port. -
Provide one 100M Ethernet communication interface, one RS-232 and one RS – 485 interface, which can be connected to computer or central control system, compatible with all third-party central control systems such as AMX, CRESTRON, RTI, etc.
-
Main communication serial ports support changing the communication baud rate to adapt to any baud rate (2400, 4800, 9600, 14400, 19200, 38400, 5600, 57600, 115200)
-
Support 4 low-voltage relay ports, normally open contacts; each group is independent and isolated, maximum to 1A 24V DC/AC loading
-
Built-in Web server, which can configure device parameters directly through the browser of various computers, tablets and mobile devices
-
Support name or remark device name
Package Contents
① 1 ⅹ Network Serial Port Expander
② 2 ⅹ 5-pin Phoenix Connector (3.81mm, male)
③ 2 ⅹ 7-pin Phoenix Connector (3.81mm, male)
④ 1 ⅹ 8-pin Phoenix Connector (3.81mm, male)
⑤ 2 ⅹ 9-pin Phoenix Connector (3.81mm, male)
⑥ 4 ⅹ Machine Screw
⑦ 2 ⅹ Mounting Ear
⑧ 1 ⅹ 24V/1A Power Adaptor with 2-pin 3.5mm Phoenix Connector
⑨ 1 ⅹ User Manual
Specifications
Technical
RS-232| Support full duplex communication mode, configurable hardware flow
control
RS-485| Support half duplex communication mode
RS-422| Support full duplex communication mode
Baud Rate| Support 2400, 4800, 9600, 14400, 19200, 38400, 5600, 57600 and
115200
LAN| 10/100 M Ethernet interface
RELAYS| Up to 1A 24VDC/AC loading
Connection
INPUTS| 1x LAN [RJ45, 8-pin female] 1×COM [7-pin Phoenix jack] 1×DC IN [2-pin
Phoenix jack]
OUTPUTS| 1×COM [7-pin Phoenix jack] 2×COM [9-pin Phoenix jack] 2×COM [5-pin
Phoenix jack] 1×RELAY [8-pin Phoenix jack]
Mechanical|
Housing| Mental Enclosure
Color| Black
Dimension| 147mm(W)×130mm(D)×42mm(H)
Weight| 673g
Power Supply| Input: AC100 – 240V 50/60Hz
Output: DC 24V/1A
Power Consumption| <2W
Operating Temperature| 0°C ~ 40°C / 32°F ~ 104°F
Storage Temperature| -20°C ~ 60°C / -4°F ~ 140°F
Relative Humidity| 20~90% RH (non-condensing)
Operation Controls and Functions
No. | Name | Function Description |
---|---|---|
1 | LAN LED | Network connection indicator. The green light flashes when the |
network communication is in good state.
2| POWER LED| The green light is on when the device is powered on.
3| RELAYS LED| Relay closing indicator. The green light is always on after the
Relay is set to be closing.
4
| RS-232/422/ 485 LED| Uplink and downlink extended serial port indicators,
flashing when sending data (red light) and receiving data (yellow light).
5| DC 24V| DC 24V/1A power input port.
6| RESET button| Press and hold the reset button for 5 seconds to reset the
factory settings.
7| LAN| 10M/100M Network communication interface.
8| MAIN COM| Main communication serial port. Connect to the central
control system or PC.
9| NEXT COM| Main control cascading output serial port.
10| RELAY OUTPUT| 4 low-voltage relay ports, normally open contacts, each
group is independent and isolated, maximum to 1A 24V DC/ AC loading.
11| RS-232/ 422 /485| Extended serial port, COM1 and COM2 support RS-232/422/
485 protocol; COM3 and COM4 support RS-232 protocol, which enables the
extender to have two-way communication with devices.
Web GUI User Guide
The product supports Web GUI control. You can configure device parameters
directly through the browser of various computers, tablets and mobile devices.
The operation method is shown as below:
Step 1, Connect the LAN port of the device to PC, and set the PC’s IP
address
to be in the same network segment with the expander. For instance, set the IP
address to be 192.168.1.64 and Subnet mask to be 255.255.255.0, as shown in
the figure below.
Step 2 , Open the browser (Google Chrome is recommended), and input the expander’s default IP address 192.168.1.100 to enter the Web GUI page.
The Web GUI pages are shown as below:
-
Overview Page
The Overview page provides basic information about the product name, firmware version, serial ID, serial Baud and the network settings.
-
Serial /Relay Page
On this page you can configure serial ports and turn on/off relays. After setting, please click “Confirm”.
-
System Page
On this page you can configure network setting, main serial port setting, product setting and restore factory settings. After setting, please click “Confirm”.
ASCII Commands
The product also supports ASCII command control. Connect the product to a PC and open a Serial Command tool on PC to send ASCII commands to control the product.
Here is the ASCII command list about Single Machine Instruction.
ASCII Commands
Serial port protocol: baud rate:115200(default) Data bits: 8 Stop bits:1
Parity: none Flow control: none
TCP/IP port: 8880 udp port:8881
x,y,z, XXX are parameters Error Code describe: E00 -> unknown command E01 ->
parameter out of range E04 -> This feature is not supported
Serial port expander id range:z = 1~999 Note: When cascading, the id numbers
of all machines cannot be set to the same.
VERSION V1.00.09
Command Code| Description| Example| Feedback| Default
Setting
System Settings
cspower x!| x ={0-1}, 1 = power on, 0 = power off x = on/off, on = power on,
off =power off| cs power 1! / cs power on!| power state: power on| power on
cr power!| get current power state| cr power!| power state:
power on/off
|
csreboot!| reboot the device| csreboot!| reboot…com x config info: baud
rate:xxx data len:8bit/7bit stop bit:1bit/2bit parity bit: none/even/odd
output type:rs232/ rs232+flow/rs485/ rs422|
csreset!| Reset to factory defaults| cs reset!| Reset to factory defaults|
crfw version!| Get Firmware version| cr fw version!| mcu boot:v1.00.01 mcu app
:v1.00.13|
crstatus!| Get device current status| cr status!| get the product all status:
power, id,com status, ip config,relay status;|
csid [x]!| Set the ID of the serial port expander, x=1-999| cs id 1!| set the
serial id is 1| serial id is 1
Command Code| Description| Example| Feedback| Default
Setting
---|---|---|---|---
cr id!| Query the ID of the serial port expander| cr id!| serial id is xxx|
cs product name xxx!| Set the product name Maximum support for 8
characters
| cs product| set product| product name
cr product name!| Query product name| cr product name!| product name is|
Serial Port Settings
cs com [x] baudrate [y]!| Serial port baud rate settings x = {1-5}, y = {1-9},
1->main com, 1->115200, 2->expand com 1, 2->57600, 3->expand com 2, 3->56000,
4->expand com 3, 4->38400, 5->expand com 4, 5->19200, 6->14400, 7->9600,
8->4800, 9->2400.| cs com 1 baudrate 1!| set com 1 baudrate is 115200| main
com ->115200 expand com 1 ->9600 expand com 2 ->9600 expand com 3 ->9600
expand com 4 ->9600
| Serial port data length Settings x = {1-5}, y = {1-2}, 1->main com, ->8bit,
2 >expand com 1, 2->7bit, 3 >expand com 2, 4- >expand com 3, 5- >expand com
4,| | |
cs com [x] datalen [y]!| When the serial data bit is set to 7bit, if the
current check bit is none, the check bit forces a surprise check and indicates
“when setting databits to 7bit, the check digit cannot be set t o none,if the
check digit is not set, odd check will be set by default!”
For example:
MAIN COM Send: cs com 1 datalen 2!
Feedback information: when setting databits to 7bit, the check digit cannot be
set to none,if the check digit is not set, odd check will be set by default!
set com 1 datalen is 7 bit| cs com 1 datalen 1!| set com 1 datalen is 8 bit|
main com ->8bit expand com 1 ->8bit expand com 2 ->8bit expand com 3 ->8bit
expand com 4 ->8bit
Command Code| Description| Example| Feedback| Default
Setting
---|---|---|---|---
cs com [x] stopbit [y]!| Serial port stop bit settings x = {1-5}, y = {1-2},
1->main com, 1->1bit, 2 >expand com 1, 2->2bit, 3 >expand com 2, 4- >expand
com 3, 5- >expand com 4,| cs com 1 stopbit 1!| set com 1 stopbit is 1 bit|
main com ->1bit expand com 1 ->1bit expand com 2 ->1bit expand com 3 ->1bit
expand com 4 ->1bit
cs com [x] paritybit [y]!| Serial port data verification Settings x = {1-5}, y
= {1-3}, 1->main com, 1 >none, 2->expand com 1, 2->even, 3->expand com 2,
3->odd, 4->expand com 3, 5->expand com 4,
Note: When the serial check bit is set to null.If the serial data bit is 7 bits, the data bit is forced to change back to 8 bits.
| cs com 1 paritybit 1!| set com 1 paritybit is none| main com ->none expand
com 1 ->none expand com 2 ->none expand com 3 ->none expand com 4 ->none
cs com [x] output type [y]!| Serial output type Settings x = {1-5}, y = {1-4},
1->main com, 1 >rs232, 2->expand com 1, 2->rs232 3->expand com 2, +flow,
4->expand com 3, 3->rs485, 5 >expand com 4, 4->rs422
Note: rs232 +flow is not supported in main com; com3 and com4 do not support RS485 and RS422.
| cs com 1 output type 1!| set com 1 output is rs232| main com ->rs232 expand
com 1 ->rs232 expand com 2 ->rs232 expand com 3 ->rs232 expand com 4 ->rs232
cr com [x] config!| Read the serial port configuration information x = {0-5},
0- >all com, 1- >main com, 2- >expand com 1, 3- >expand com 2, 4- >expand com
3, 5- >expand com 4,| cr com 1 config!| com 1 config info: baud rate:xxx data
len:8bit/7bit stop bit:1bit/2bit parity bit: none/even/odd output type:rs232/
rs232+flow/rs485/ rs422 ……|
Command Code| Description| Example| Feedback| Default
Setting
---|---|---|---|---
Network Port Settings
cs ip addr xxx.xxx.xxx.xxx!| set network ip address ip range
1.0.0.1~223.255.255.254
| cs ip addr 192.168.1.2!| set ip address is 192.168.1.2| ip address is
192.168.1.100
cs subnet xxx.xxx.xxx.xxx!| set network subnet mask xxx=254|252|248|240|224|
192|128|0| cs subnet 255.255.255.0!| set subnet mask is 255.255.255.0| subnet
mask is 255.255.255.0
cs gateway xxx.xxx.xxx.xxx!| set network gateway gateway range
1.0.0.1~223.255.255.254| cs gateway 192.168.1.1!| set gateway is 192.168.1.1|
gateway is 192.168.1.1
cs ip mode [x]!| set ip mode, x={0-1} 0=dhcp 1=static ip| cs ip mode 1!| ip
mode is static ip| ip mode is static ip
cs tcp/ip port x!| tcp/ip port settings, x={1-65535}| tcp/ip port is 8000!|
set tcp/ip port is 8000| tcp/ip port is 8880
cs udp port x!| udp port Settings, x={1-65535}| cs udp port 8001!| set udp
port is 8001| udp port is 8881
cr ipconfig!| Network configuration query| cr ipconfig!| ip mode: static/dhcp
ip: 192.168.1.100 subnet mask: 255.255.255.0 gateway: 192.168.1.1 mac address:
6C:DF:FB:00:00:00 tcp/ip mode:server tcp/ip port=8880 udp mode:server udp port
=8881|
Data Send
N/A| Expand serial port data reporting data->cmd data (The data range is 1 to
512) x={1-4} 1->com 1 2->com 2 3->com 3 4->com 4| COM1 : ABCD| COM1 : N/A MAIN
COM : cs ch 1 report ABCD end!|
cs ch [x] cmd [data] end!| The data of the main serial port is issued
data->cmd data (The data range is1 to 512 ) x={0 4} 0->all com 1->com 1 2->com
2 3->com 3 4->com 4| MAIN COM : cs ch 1 cmd ABCD end!| MAIN COM : N/A COM1 :
ABCD|
Command Code| Description| Example| Feedback| Default
Setting
---|---|---|---|---
Relay Setting
cs relay [x] to [y]!| relay switch x={0-4} y={0-1} 0- >all relay port 0->off
1- >relay port 1 1->on 2 >relay port 2 3- >relay port 3 4- >relay port 4| cs
relay 1 to 1!| set relay 1 open|
cr relay [x]!| relay inquiry x={0-4} 0->all relay port 1->relay port 1 2-
relay port 2 3- >relay port 3 4- >relay port 4| cr relay 0!| relay 1 is open/close relay 2 is open/close relay 3 is open/close relay 4 is open/close all relays are open all relays are close| relay 1 is close relay 2 is close relay 3 is close relay 4 is close
Here is another ASCII command list about Cascading Order.
ASCII Commands
Serial port protocol: baud rate:115200(default) Data bits: 8 Stop bits:1
Parity: none Flow control: none
TCP/IP port: 8880 udp port:8881
x,y,z, XXX are parameters Error Code describe: E00 -> unknown command E01 ->
parameter out of range E04 -> This feature is not supported
Serial port expander id range:z = 1~999 Note: When cascading, the id numbers
of all machines cannot be set to the same.
VERSION V1.00.09
Command Code| Description| Example| Feedback| Default
Setting
System Settings
id[z] cs power x!| x ={0-1}, 1 = power on, 0 = power off x = on/off, on =
power on, off =power of| id[1] cs power 1! / cs power on!| id[1] power state:
power on| power on
id[z] cr power!| get current power state| id[1] cr power!| id[1] power state:
power on/off|
Command Code| Description| Example| Feedback| Default
Setting
---|---|---|---|---
id[z] cs reboot!| reboot the device| id[1] cs reboot!| id[1] reboot… id[1] com
x config info: baud rate:xxx data len:8bit/7bit stop bit:1bit/2bit parity bit:
none/even/odd output type: rs232/rs232+flow/ rs485/rs42 ……|
id[z] cs reset!| Reset to factory defaults| id[1] cs reset!| id[1] reset to
factory defaults|
id[z] cr fw version!| Get Firmware version| id[1] cr fw version!| id[1] mcu
boot:v1.00.01 mcu app :v1.00.13|
id[z] cr status!| Get device current status| id[1] cr status!| get the product
all status: power, id,com status, ip config,relay status;|
id[z] cs id [x]!| Set the ID of the serial port expander,x=1-999| id[1] cs id
1!| id[1] set the serial id is 1| serial id is 1
id[z] cr id!| Query the ID of the serial port
expander
| id[1] cr id!| id[1] serial id is xxx|
id[z] cs product name xxx!| Set the product name Maximum support for 8
characters| id[1] cs product| id[1] set product| product name
id[z] cr product| Query product name| id[1] cr product| id[1] product|
Serial Port Settings
id[z] cs com [x] baudrate [y]!| Serial port baud rate settings x = {1-5}, y =
{1-9}, 1->main com, 1 >115200, 2->expand com 1, 2 >57600, 3->expand com 2, 3
56000, 4->expand com 3, 4 >38400, 5->expand com 4, 5 >19200, 6->14400, 7->9600, 8->4800, 9->2400.| id[1] cs com 1 baudrate 1!| id[1] set com 1 baudrate is 115200| main com ->115200 expand com 1 ->9600 expand com 2 ->9600 expand com 3 ->9600 expand com 4 ->9600
Command Code| Description| Example| Feedback| Default Setting
---|---|---|---|---
id[z] cs com [x] datalen [y]!| Serial port data length Settings x = {1-5}, y = {1-2}, 1->main com, 1->8bit, 2 >expand com 1, 2->7bit, 3 >expand com 2, 4- expand com 3, 5- >expand com 4,
When the serial data bit is set to 7-bit, if the current check bit is none, the check bit forces a surprise check and indicates “when setting databits to 7-bit, the check digit cannot be set to none,if the check digit is not set, odd check will be set by default!” For example:
MAIN COM Send: id[1] cs com 1 datalen 2!
Feedback information: when setting databits to 7bit, the check digit cannot be set to none,if the check digit is not set, odd check will be set by default! id[1] set com 1 datalen is 7-bit
| id[1] cs com 1 datalen 1!| id[1] set com 1 datalen is 8-bit| main com->8bit
expand com 1 ->8bit expand com 2 ->8bit expand com 3 ->8bit expand com 4
->8bit
id[z] cs com [x] stopbit [y]!| Serial port stop bit settings x = {1-5},y =
{1-2}, 1->main com, 1->1bit, 2 >expand com 1, 2->2bit, 3 >expand com 2, 4-
expand com 3, 5- >expand com 4,| id[1] cs com 1 stopbit 1!| id[1] set com 1 stopbit is 1 bit| main com->1bit expand com 1 ->1bit expand com 2 ->1bit expand com 3 ->1bit expand com 4 ->1bit
id[z] cs com [x] paritybit [y]!| Serial port data verification Settings
x = {1-5}, y = {1-3}, 1->main com, 1->none, 2 >expand com 1, 2->even, 3->expand com 2, 3->odd, 4 >expand com 3, 5->expand com 4,
Note: When the serial check bit is set to null.If the serial data bit is 7 bits, the data bit is forced to change back to 8 bits.
| id[1] cs com 1 paritybit 1!| id[1] set com 1 paritybit is none| main com
->none expand com 1 ->none expand com 2 ->none expand com 3 ->none expand com
4 ->none
Command Code| Description| Example| Feedback| Default
Setting
---|---|---|---|---
id[z] cs com [x] output type [y]!| Serial output type Settings x = {1-5},y =
{1-4}, 1->main com, 1->rs232, 2->expand com 1, 2->rs232 3->expand com 2,
+flow, 4->expand com 3, 3->rs485, 5->expand com 4, 4->rs422 Note: rs232 +flow
is not supported in main com; com3 and com4 do not support RS485 and RS422.|
id[1] cs com 1 output type 1!| id[1] set com 1 output is rs232| main com
->rs232 expand com 1 ->rs232 expand com 2 ->rs232 expand com 3 ->rs232 expand
com 4 ->rs232
id[z] cr com [x] config!| Read the serial port configuration information x =
{0-5},
0- >all com,
1- >main com,
2- >expand com 1,
3- >expand com 2,
4- >expand com 3,
5- >expand com 4,
| id[1] cr com 1 config!| id[1] com 1 config info: baud rate:xxx data
len:8bit/7bit stop bit:1bit/2bit parity bit: none/even/odd output type:rs232/
rs232+flow/rs485/ rs422 ……|
Network Port Settings
id[z] cs ip addr xxx.xxx.xxx.xxx!| set network ip address ip range
1.0.0.1~223.255.255.254
| id[1] cs ip addr 192.168.1.2!| id[1] set ip address is 192.168.1.2| ip
address is 192.168.1.100
id[z] cs subnet xxx.xxx.xxx.xxx!| set network subnet mask xxx
=254|252|248|240|224|192| 128|0
| id[1] cs subnet 255.255.255.0!| id[1] set subnet mask is 255.255.255.0|
subnet mask is 255.255.255.0
id[z] cs gateway xxx.xxx.xxx.xxx!| set network gateway gateway range
1.0.0.1~223.255.255.254
| id[1] cs gateway 192.168.1.1!| id[1] set gateway is 192.168.1.1| gateway is
192.168.1.1
id[z] cs ip mode [x]!| set ip mode, x={0-1} 0=dhcp 1=static ip| id[1] cs ip
mode 1!| id[1] ip mode is static ip| ip mode is static ip
id[z] cs tcp/ip port x!| tcp/ip port settings, x={1-65535}| id[1] tcp/ip port
is 8000!| id[1] set tcp/ip port is 8000| tcp/ip port is 8880
id[z] cs udp port x!| udp port Settings,x={1-65535}| id[1] cs udp port 8001!|
id[1] set udp port is 8001| udp port is 8881
id[z] cr ipconfig!| Network configuration query| id[1] cr ipconfig!| id[1] ip
mode: static/dhcp ip: 192.168.1.100 subnet mask: 255.255.255.0 gateway:
192.168.1.1 mac address: 6C:DF:FB:00:00:00 tcp/ip mode:server tcp/ip port=8880
udp mode:server udp port =8881|
Command Code| Description| Example| Feedback| Default
Setting
---|---|---|---|---
Relay Setting
id[z] cs relay [x] to [y]!| relay switch x={0-4} y={0-1} 0- >all relay port
0->off 1- >relay port 11->on 2->relay port 2 3- >relay port 3 4- >relay port
4| id[1] cs relay 1 to 1!| id[1] set relay 1 open|
id[z] cr relay [x]!| relay inquiry x={0-4} 0->all relay port 1->relay port 1
2- >relay port 2 3- >relay port 3 4- >relay port 4| id[1] cr relay 0!| id[1]
relay 1 is open/close id[1] relay 2 is open/close id[1] relay 3 is open/close
id[1] relay 4 is open/close id[1] all relays are open id[1] all relays are
close| relay 1 is close relay 2 is close relay 3 is close relay 4 is close
Cascade Control
id[z] cs ch x cmd ABCD end!| The data of the main serial port is issued
data->cmd data
(The data range is1 to 512 ) z = {1~999},x={0-4}
- When using cascade, you first need to use main com to issue a command with id flag, and the feedback information will be marked with id. At this time, the machine enters the cascade state. For example : MAIN COM : id[1] cs ch 1 cmd ABCD end! COM1 : id[1] ABCD
- If next time the main com sends the command without the id mark, the feedback message will not carry the id mark. At this time, the machine enters the non- cascading state.
For example : MAIN COM : cs ch 1 cmd ABCD end! COM1 : ABCD
Note: When cascading, the id numbers of all machines cannot be set to the same.
| MAIN COM :
id[1] cs ch 1 cmd ABCD end!| MAIN COM : N/A COM1 : id[1] ABCD|
Command Code| Description| Example| Feedback| Default
Setting
---|---|---|---|---
N/A| Sub-machine data report data->cmd data
(The data range is 1 to 512)
When using cascading, when the extended COM of any machine reports data to the
host, each machine must be in the cascading state, otherwise, the data
received by the host will have errors.| COM1 : ABDC| COM1 : N/A MAIN COM :
id[xxx] cs ch 1 report ABCD end!|