SENECA R-PASS-0-2-0 R-Pass IIoT Edge Gateways Installation Guide
- June 4, 2024
- SENECA
Table of Contents
INSTALLATION MANUAL
R-PASS
MI00555-1-EN
INSTALLATION MANUAL
PRELIMINARY WARNINGS
The word WARNING preceded by the symbol indicates conditions or actions
that put the user’s safety at risk.
The word ATTENTION preceded by the symbol indicates conditions or actions
that might damage the instrument or the connected equipment. The warranty
shall become null and void in the event of improper use or tampering with the
module or devices supplied by the manufacturer as necessary for its correct
operation, and if the instructions contained in this manual are not followed.
| WARNING: The full content of this manual must be read before any
operation.
The module must only be used by qualified electricians.
Specific documentation is available using the QR-CODE shown on page 1.
---|---
| The module must be repaired and damaged parts replaced by the Manufacturer.
The product is sensitive to electrostatic discharges. Take appropriate
measures during any operation.
| Electrical and electronic waste disposal (applicable in the European Union
and other countries with recycling).
The symbol on the product or its packaging shows the product must be
surrendered to a collection center
authorized to recycle electrical and electronic waste.
www.seneca.it/products/r-pass
R-PASS
DOCUMENTATION
MODULE LAYOUT
Weight: 170 g; Enclosure: UL94-V0 self-extinguishing PC/ABS material, black.
SIGNALS VIA LED ON FRONT PANEL
LED | STATUS | LED meaning |
---|---|---|
D01….D04 | On | Output enabled |
Off | Output disabled | |
DI1…D14 | On | Input activated |
Off | Input deactivated | |
DO AUX | On | Auxiliary supply active |
Off | Fault or wiring error | |
STS (Status) | Flashing | The module is working correctly |
Off | Locking system | |
On | Locking system | |
VPN | On | VPN connection active |
Flashing | VPN connection problems | |
SRV | On | VPN BOX “SERVICE connection is working correctly |
Flashing | VPN BOX “SERVICE” connection in error | |
UPS | On | UPS active (only in the presence of the R-COMM accessory) |
Off | UPS inactive | |
LOG | On | Data Logger is active and working correctly |
Flashing | Data Logger in error | |
WIFI (only R-PASS-W) | On | WiFi-enabled in Station mode |
Flashing | WiFi-enabled in access-point mode | |
On | WiFi signal strength in Station mode | |
PWR | On | Device powered correctly |
RX1 RX2
/| On| Incorrect RS485 connection
Flashing| Reception of data packet completed on RS485
TX1 / TX2| Flashing| Transmission of data packet completed on RS485
ETH ACT (Yellow)| Flashing| Packet transit on Ethernet port
ETH LNK (Green)| Flashing| Ethernet port connected
TECHNICAL SPECIFICATIONS
CERTIFICATIONS|
https://www.seneca.it/products/r-pass/doc/CE_declaration
---|---
ENVIRONMENTAL CONDITIONS| Operating temperature: from -25°C to +65 °C
Humidity: 10% ÷ 90% non condensing. Storage temperature: from -30°C to +80°C
Protection rating: IP20
ASSEMBLY| 35mm DIN rail IEC EN60715
CONNECTIONS| Removable 3.5mm pitch terminal block, 1.5mm 2 max cable
section
COMMUNICATION PORTS| 1 USB A connector
4 RJ45 Ethernet ports
1 RS485/RS232 serial port configurable via software
1 RS485 serial port
1 micro USB dedicated to debugging
POWER SUPPLY| 10 ÷ 40Vdc; 19 ÷ 28Vac; 8W max
INSULATION|
DIGITAL OUTPUTS| OptoMOS® 30Vdc, 25mA max
DIGITAL INPUTS| Number of channels: 4, Absorbed current: 2.2mA
Input voltage: 0÷30V, Threshold ON > 9V, Threshold OFF < 8V
IEC6113-2 Type 1 & 3 compliant
ANALOGUE INPUTS| Voltage 0 ÷ 30Vdc, impedance 20kΩ
Current 0 ÷ 25mA, impedance ~ 50Ω
AUXILIARY VOLTAGE OUTPUT| 12Vdc; Max. 50mA
WI-FI (only R-PASS-W)| Integrated WiFi 802.11 b/g/n, 2.4 ÷ 2.4835GHz
band, max Output Power: 17dBm (50mW)
Through the lateral connection, it is possible to add optional modules.
For more information on accessories and optional modules, visit the website on
page 1 or scan the QR-CODE.
ELECTRICAL CONNECTIONS
CAUTION
The upper power supply limits must not be exceeded, as this could cause
serious damage to the module.
Switch the module off before connecting inputs and outputs.
To meet the electromagnetic immunity requirements:
- use shielded signal cables;
- connect the shield to a preferential instrumentation earth system;
- separate shielded cables from other cables used for power installations (transformers, inverters, motors, etc…).
|
---|---
DIP-SWITCH
The DIP-SWITCHES on the back of the device have the following functions:
SW1
DIP1| RESERVED| DIP3| ON| DEFAULT SETTINGS
DIP2| RESERVED| DIP4| ON
To access the DIP-SWITCH it is necessary to remove the bottom of the
instrument.
ETHERNET CONNECTION RULES
For the Ethernet cabling between the devices, the use of the unshielded CAT5
or CAT5e cable is required.
FACTORY IP ADDRESS
The default module IP address is static: 192. 168. 90. 101
WEB SERVER
To access the maintenance Web Server with the 192.168.90.101 factory IP
address (Default user: admin; Default password: admin) http://192.168.90.101
CAUTION
DO NOT USE DEVICES WITH THE SAME IP ADDRESS IN THE SAME ETHERNET NETWORK.
SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY;
Tel. +39.049.8705359 –
Fax +39.049.8706287
CONTACT INFORMATION
Technical support| support@seneca.it| Product
information| sales@seneca.it
---|---|---|---
This document is the property of SENECA srl. Copies and reproduction are
prohibited unless authorized.
The content of this document corresponds to the described products and
technologies.
Stated data may be modified or supplemented for technical and/or sales
purposes.