RAB Aerobay Linear LED High Bay Instruction Manual
- June 8, 2024
- RAB
Table of Contents
INSTRUCTIONS
AEROBAY® INSTALLATION
Aerobay Linear LED High Bay
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and
all applicable local codes. Proper grounding is required for safety. THIS
PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
WARNING:
• Make certain power is OFF before installing or maintaining fixture. No user
serviceable parts inside.
PREPARING FOR INSTALLATION
-
Using two hands, pull Center Housing Channel straight up as shown in Fig 1.
-
Center Housing Channel will lock into position as shown in Fig. 2.
-
Verify that the Center Housing Channel is locked in place.
IMPORTANT: Once the fixture has been fully expanded into the operating position, do not collapse the Center Housing Channel without first depressing the Release Clips.
FOR SENSOR ARM MOUNTING
Follow Steps below to install sensor before mounting/wiring fixture.
(Applicable for units ordered with Passive InfraRed Occupancy Sensor or LCS,
Lightcloud Motion Sensor.)
-
Remove applicable knockouts to install Sensor as shown in Fig. 3.
-
Run Sensor wire through the Knockout at end of the fixture and connect internally.
-
Place Sensor Arm onto the fixture and secure with Screw (provided) as shown in Fig.4.
-
Arm will lock into place, secure with Screw (provided).
CORD AND PLUG OPTIONS
For units ordered with the following suffixes see voltage information below.
- (/8C) 8ft Cord (only), 120-277V, 480V
- (/ 8CP) 8ft Cord & Straight Plug, 120V (only), NEMA 5-15P
- (/8CPT) 8ft Cord & Twist Lock Plug, 120V (only) NEMA L5-15P
- (/8CP2) 8ft Cord & Straight Plug, 277V (only), NEMA 7-15P
- (/8CPT2) 8ft Cord & Twist Lock Plug, 277V (only) NEMA L7-15P
- (/8CPT4) 8 ft Cord & Twist Lock Plug, 480V (only) NEMA L8-20P
FOR V-HOOK MOUNTING OR CHAIN MOUNTING
Mount Housing to sturdy ceiling structure as follows:
-
V-Hooks (2) and Chain are provided for mounting. Secure V-Hooks through Bracket Hole at back of Center Housing Channel, or secure chains through Chain Mounting Slots in the ends of the housing shown in Fig. 5.
-
Fixture mounting height and spacing should be determined by application requirements.
-
Remove Access Plate and feed supply wire with strain relief connector. Make electrical connections as shown in wiring diagram (Fig. 7). Use approved wiring connectors and wire to local NEC codes. Push all wires back into Center Housing Channel. Be careful not to pinch wires.
-
Reinstall Access Plate and secure with supplied Screw (1).
FOR PENDANT MOUNTING
(Accessory ordered separately – Model# JBARBAY2)
-
Choose length of 1/2” NPS Pendant Stem (supplied by others).
-
Install Pendant Junction Box (ordered separately) to Center Housing Channel by mounting Pendant Junction Box on Center Housing Channel and securing with supplied Screws (4) and Washers (4) as shown in Fig. 6.
-
Feed wires through Pendant Stem and into Pendant Junction Box. Wire the housing leads to supply wires using UL listed wire connectors according to NEC and local codes in the Pendant Junction Box. Push all wires back into Pendant Junction Box, install Side Panels (2) with supplied Screws (2). Be careful not to pinch wires.
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. Units ordered with (/480) suffix are 480V, 50Hz or 60Hz. For 0-10V Dimming, follow the wiring directions as shown in Fig. 7.
- Connect the black fixture lead to the LINE supply lead.
- Connect the white fixture lead to the COMMON supply lead.
- Connect the GROUND wire from fixture to supply ground.
- Connect the purple fixture lead to the (V+) DIM lead.
- Connect the pink (or gray) fixture lead to the (V-) DIM lead.
NOTE: Do not connect DIM V+ (purple)/ DIM V- (pink or gray) to line voltage or supply ground.
TROUBLESHOOTING
- Check that the line voltage at the fixture is correct.
- Be sure the fixture is grounded properly.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
- Lens can be washed only after removing from fixture and only in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Do not use chemicals to clean Lens or fixture.
- Do not open fixture to clean the LED. Do not touch the LED.
Note: These instructions do not cover all details or variations in equipment nor do they provide every possible situation during installation, operation or maintenance.
DIMENSIONAL DRAWINGS
To reduce the risk of electric shock, disconnect both normal and emergency power supplies and converter connector of the emergency driver before servicing. Do not attempt to service the emergency driver. The use of accessory equipment may cause an unsafe condition. Do not use this product for other than intended use. Refer any servicing indicated by these checks to a Qualified Service Personnel.
BATTERY BACKUP MODELS
WIRING
CAUTION: FOR BATTERY BACKUP FIXTURE. Voltage could be present in BAT
TERY. To prevent high voltage from being present on output leads, inverter
connector must be open. Do not join
BAT TERY connector until installation is complete and AC power is supplied to
the emergency driver (Fig. 8).
NOTE: Make sure that the necessary branch circuit wiring is available. An
UNSWITCHED AC source of power is required. The emergency driver must be fed
from the same branch circuit as the LED driver.
CAUTION: Do not use any supply voltage other than 120-277V 50/60 HZ.
-
Connect UNSWITCHED HOT fixture lead to HOT AC supply line.
-
If using an UNSWITCHED circuit, connect UNSWITCHED and SWITCHED lines together.
-
If using a SWITCHED circuit, connect SWITCHED HOT AC fixture lead to the external SWITCHED.
-
Connect the NEUTRAL fixture lead to the NEUTRAL supply line.
-
For 0-10V Dimming, connect DIM (+) and DIM (-) to the supply DIM (+) and DIM (-).
-
Connect GROUND lead from the fixture to the supply ground.
Do not connect GROUND to the output leads. -
All unused lead must be capped and insulated.
-
After installation is complete, supply AC power to the fixture and connect the BATTERY.
-
When power is on, the fixture should be on and the Charging Indicator Light should illuminate to indicate the battery is charging.
-
Once the BATTERY has charged for at least one hour, a short duration test may be performed by pressing the test button.
-
After the battery has charged for 24 hours, a long duration test can be performed by shutting power to the fixture.
OPERATION
- When AC power is applied, the charging indicator light is illuminated, indicating that the BATTERY is being charged.
- When power fails, the standby power automatically switches to emergency power (internal battery), operating at reduced illumination. Not all LED boards will illuminate with standby power. The emergency driver supplies 25W of power in standby power for a minimum of 90 minutes.
- When AC power is restored, the emergency driver automatically returns to charging mode.
MAINTENANCE
Although no routine maintenance is required to keep the emergency driver
functional, it should be checked periodically to ensure that it is working.
The following schedule is
recommended:
- Visually inspect the charging indicator light monthly. It should be illuminated.
- Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds.
- Conduct a 90-minute discharge test once a year. Fixture would operate at reduced illumination for a minimum of 90 minutes.
TROUBLESHOOTING
- Is the fixture grounded properly?
- If the charging indicator light does not illuminate after pressing the test button, check if battery is connected properly.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
© 2021 RAB LIGHTING Inc.
AEROBAY-IN-1121
73651-RAB
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail swered promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request
RAB WARRANTY: RAB’S warranty is subject to all terms and conditions found at
rablighting.com/warranty.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>