SURE SA15AZ Vantix Line iM Air Conditioners User Manual

June 13, 2024
SURE

SURE SA15AZ Vantix Line iM Air Conditioners

Product Information

The Air Conditioners SA15AZ is part of the VantixTM Line iM Air Conditioners series. It offers cooling efficiencies of up to 15.2 SEER2/9.8 EER2 and comes in nominal sizes ranging from 2 to 5 Ton [7.0 to 17.6 kW]. The cooling capacities range from 22.8 to 56.0 kBTU [6.68 to 16.4 kW]. The product operates on R-410A refrigerant and has a voltage of 208-230/60.

Features and Benefits

  • 3-speed operation when installed with a 24V two-stage thermostat
  • Provides precise temperature control, advanced humidity control, and greater efficiency

Model Number Identification

The model number SA15AZ provides the following information:

  • Brand: Sure Comfort
  • Product Category: Air Conditioners
  • SEER2 Region: 15.2
  • Refrigerant: R-410A
  • Capacity BTU/HR: 24,000 [7.03 kW]
  • Major Series: A – 1st Design
  • Voltage: 1ph, 208-230/60
  • Type: 3+ Stage
  • Minor Series: N – Non-Communicating

Product Usage Instructions

To use the Air Conditioners SA15AZ, follow these instructions:

  1. Ensure that the unit is properly installed according to the installation manual.
  2. Connect the unit to a power source with the correct voltage (208-230/60).
  3. Set the desired temperature and operation mode using a compatible 24V two-stage thermostat.
  4. The unit offers 3-speed operation when installed with the specified thermostat. Adjust the fan speed as needed.
  5. The unit provides precise temperature control and advanced humidity control. Set the desired humidity level if applicable.
  6. Regularly clean and maintain the unit according to the maintenance instructions in the user manual.

For further information or troubleshooting, refer to the complete user manual or contact customer support.

SA15AZ

  • Cooling Efficiencies up to: 15.2 SEER2/9.8 EER2
  • Nominal Sizes: 2 to 5 Ton [7.0 to 17.6 kW]
  • Cooling Capacities: 22.8 to 56.0 kBTU [6.68 to 16.4 kW]

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners

Features and Benefits

  • Diagnostics & Bluetooth®1 Connectivity: With the Sure
    Comfort Contractor App, built-in technology makes advanced set-up, monitoring, troubleshooting and repairing the product easier than ever before

  • Variable Speed Twin Rotary Compressor & Inverter Drive:

    • Features Inverter operation from 40 to 70% capacity or 100% capacity via line voltage with the Smart Thermostat
    • 3-speed operation when installed with a 24V two-stage thermostat
    • Provides precise temperature control, advanced humidity control and greater efficiency
  • Swept Wing Fan Technology: Features quieter operation and improved unit acoustics

  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability

  • Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space—provides a minimum working area of 27-square inches for easier access

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.

Air Conditioners

Designates Metric Conversions

Available Models Description
SA15AZ24AJ3NA Vantix™ Line 2 ton 3+ Speed iM Air Conditioner – 208/230/1/60
SA15AZ36AJ3NA Vantix™ Line 3 ton 3+ Speed iM Air Conditioner – 208/230/1/60
SA15AZ48AJ3NA Vantix™ Line 4 ton 3+ Speed iM Air Conditioner – 208/230/1/60
SA15AZ60AJ3NA Vantix™ Line 5 ton 3+ Speed iM Air Conditioner – 208/230/1/60

Standard Equipment

R-410A Refrigerant

Variable Speed Twin Rotary Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays

General Data

Model No.| SA15AZ24AJ3| SA15AZ36AJ3| SA15AZ48AJ3| SA15AZ60AJ3
---|---|---|---|---
Nominal Tonnage| 2.0| 3.0| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 91| 119| 130| 154
Compressor Type| Twin Rotary
Outdoor Coil|
Net face area – Outer Coil| 11.79| 14.4| 16.42| 17.88
Net face area – Inner Coil| —| —| —| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276
Number of rows| 1| 1| 1| 1
Fins per inch| 24| 24| 24| 24
Outdoor Fan|
Diameter – in.| 20| 24| 24| 26
Number of blades| 3| 3| 3| 3
Motor hp| 1/5| 1/5| 1/3| 1/2
CFM| 2908| 4138| 4529| 5274
RPM| 1075| 1000| 1075| 1075
watts| 170| 267| 294| 370
Shipping weight – lbs.| 174| 198| 230| 251
Operating weight – lbs.| 167| 191| 223| 244
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 30| 40| 50
Minimum circuit ampacity³| 12| 20| 25| 32
Compressor|
Rated load amps| 10| 15| 20| 25
Locked rotor amps| 65| 70| 96| 119

  • Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
  • HACR type circuit breaker of fuse.
  • Refer to the National Electrical Code manual to determine wire, fuse and disconnect size requirements

Accessories

Model No.| SA15AZ24AJ3| SA15AZ36AJ3| SA15AZ48AJ3| SA15AZ60AJ3
---|---|---|---|---
Compressor crankcase heater*| N/A| N/A| N/A| N/A
Low ambient control| 47-102709-10| 47-102709-10| 47-102709-10| 47-102709-10
Compressor sound cover| 68-23427-27| 68-23427-28| 68-23427-29| 68-23427-29
Low pressure control| 47-103454-01| 47-103454-01| 47-103454-01| 47-103454-01
High pressure control| 47-103669-02| 47-103669-02| 47-103669-02| 47-103669-02
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V

Crankcase Heater recommended with Low Ambient Kit.

Weighted Sound Power Level

Unit Size – Voltage, Series| Standard Rating (dBA) Low Speed/ High Speed| TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)| Sound Power Level [dB(A)] with Sound Blanket
---|---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
SA15AZ24AJ3| 63.3| 35.9| 47.9| 55.3| 53.2| 50.4| 47.1| 43.8| ****



Sound Blankets – Standard

71.7| 46.1| 59.1| 63.2| 60.8| 58.7| 56.5| 47.9
SA15AZ36AJ3| 61.4| 38.5| 48.0| 53.8| 49.2| 45.9| 47.0| 47.4
72.9| 47.5| 59.5| 64.9| 60.7| 62.6| 57.0| 49.6
SA15AZ48AJ3| 63.8| 42.3| 45.9| 53.5| 48.9| 45.8| 59.1| 36.4
76.2| 49.4| 61.4| 68.1| 53.9| 60.8| 57.4| 48.5
SA15AZ60AJ3| 65.7| 39.7| 49.0| 58.2| 54.5| 52.2| 53.8| 41.3
76.7| 49.3| 64.6| 68.1| 65.1| 62.6| 58.6| 53.0

NOTE : Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

Unit Dimensions


Model No.

| Operating| Shipping
---|---|---
H (Height)| L (Length)| W (Width)| H (Height)| L (Length)| W (Width)
Inches| mm| Inches| mm| Inches| mm| Inches| mm| Inches| mm| Inches| mm
SA15AZ24AJ3| 27.00| 686| 29.75| 756| 29.75| 756| 28.50| 724| 32.38| 822| 32.38| 822
SA15AZ36AJ3| 27.00| 686| 33.75| 857| 33.75| 857| 28.50| 724| 36.38| 924| 36.38| 924
SA15AZ48AJ3| 31.00| 787| 33.75| 857| 33.75| 857| 32.50| 826| 36.38| 924| 36.38| 924
SA15AZ60AJ3| 31.00| 787| 35.75| 908| 35.75| 908| 32.50| 826| 38.38| 975| 38.38| 975

Designates Metric Conversions

CLEARANCES

NOTE : NUMBERS IN () = mm
IMPORTANT : When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re- circulation of discharge air.

Control Wiring

Application Guidelines

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
  2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
  3. Maximum outdoor operating air temperature is 125°F (51.7°C).
  4. For reliable operation, unit should be level in all horizontal planes.
  5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  6. Do not apply capillary tube indoor coils to these units.
  7. Factory-supplied filter drier must be installed.

Refrigerant Line Size Information

15/16 SEER2 Variable Speed Air Conditioners



Unit Size

| ****


Allowable Liquid Line Size

| ****

Allowable Vapor Line Size

| Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
Maximum Vertical Separation / Capacity Multiplier



2.0 Ton

**SEE NOTE 3

| 1/4″| 5/8″| 25/1.00| 50/0.99| 32/0.98| 40/0.97| NR| NR
5/16″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
1/4″| 3/4″| 25/1.00| 50/1.00| 32/0.99| 40/0.99| NR| NR
5/16″| 3/4″
| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3/8″| 3/4″**| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98



3 Ton

| 5/16″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 37/0.91| NR
3/8″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
5/16″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 37/0.97| 22/0.96
3/8″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
1/2″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96



4 Ton

| 3/8″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
1/2″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97



5 Ton

| 3/8″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
1/2″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 38/0.96
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 50/0.96

NOTES:

  1. Do not exceed 150 ft. linear line length.
  2. Do not exceed 50 ft.vertical separation between indoor and outdoor units.
  3. 3/4” suction line should only be used for 2 ton systems if the outdoor unit is below or at the same level as the indoor unit to ensure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

15/16 SEER2 Variable Speed Air Conditioners



Unit Size

| ****


Allowable Liquid Line Size

| ****

Allowable Vapor Line Size

| Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Meters)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
Maximum Vertical Separation / Capacity Multiplier



2.0 Ton

**SEE NOTE 3

| 6.35 [1/4]| 15.88 [5/8]| 8/1.00| 15/0.99| 10/0.98| 10/0.97| NR| NR
7.94 [5/16]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
9.53 [3/8]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
6.35 [1/4]| 19.05 [3/4]| 8/1.00| 15/0.99| 10/0.99| 12/0.99| NR| NR
7.94 [5/16]| 19.05 [3/4]
| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98
9.53 [3/8]| 19.05 [3/4]**| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98



3 Ton

| 7.94 [5/16]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 11/0.91| NR
9.53 [3/8]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 11/0.97| 7/0.96
9.53 [3/8]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
12.7 [1/2]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96



4 Ton

| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
12.7 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
12.7 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97



5 Ton

| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
12.7 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 12/0.96
12.7 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 15/0.97

NOTES:

  1. Do not exceed 46 meters linear line length.
  2. Do not exceed 15 meters vertical separation between indoor and outdoor units.
  3. 19.05mm [3/4″] vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as the indoor unit to ensure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop

Additional Oil, Oz.

Lineset Length| 50| 60| 70| 80| 90| 100| 110| 120| 130| 140| 150
2T| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6| 7
3T| N/A| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6
4T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
5T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A

Performance Data @ AHRI Standard Conditions – Cooling

Designated Tested Combination (DTC)

Outdoor Unit| Air Handler| Total Capacity BTU/H [kW]| Net Sensible BTU/H [kW]| Net Latent BTU/H [kW]| SEER2| EER2| Indoor CFM [L/s]
SA15AZ24AJ3| SH3VZ2417STACN| 22,800 [6.7]| 17,600 [5.2]| 5,200 [1.5]| 15.2| 9.8| 750 [354.0]
SA15AZ36AJ3| SH3VZ3617STACN| 34,200 [10.0]| 26,600 [7.8]| 7,600 [2.2]| 15.2| 9.8| 1,125 [530.9]
SA15AZ48AJ3| SH3VZ4821STACN| 45,500 [13.3]| 35,500 [10.4]| 10,000 [2.9]| 15.2| 9.8| 1,425 [672.5]
SA15AZ60AJ3| SH3VZ6024STACN| 55,500 [16.3]| 43,000 [12.6]| 12,500 [3.7]| 15.2| 9.8| 1,675 [790.5]

NOTE : This data includes DTC (Designated Test Combination) ratings for reference only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.

Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY
Sure Comfort® will furnish a replacement for any part of this product that fails in everyday use and service within the applicable period stated, by the terms of the limited warranty.
For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate

Conditional Parts
(Registration Required)……………………………… Ten (10) Years

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices
© 2023 Rheem Manufacturing Company. Sure Comfort trademarks are owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Sure Comfort reserves the right to make changes without notice.
Sure Comfort
5600 Old Greenwood Road
Fort Smith, Arkansas 72908
www.surecomfort.com
Sure Comfort Canada 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 surecomfort.ca

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SURE User Manuals

Related Manuals